Radon Mitigation >> EPA Radon

RADON MITIGATION STANDARDS 1.0 BACKGROUND The 1988 Indoor Radon Abatement Act (IRAA) required the Environmental Protection Agency (EPA) to develop a voluntary program to evaluate and provide information on contractors who offer radon control services to homeowners. The Radon Contractor Proficiency (RCP) Program was established to fulfill this EPA Radon portion of the IRAA. 

In December 1991, EPA published "Interim Radon Mitigation Standards" as initial guidelines for evaluating the performance of radon mitigation contractors under the RCP Program. Over the past six years, EPA Radon the effectiveness of the basic radon mitigation techniques set forth in the, "Interim Standards" has been validated in field applications throughout the United States. 

This experience now serves as the basis for the more detailed and final Radon Mitigation Standards (RMS) set forth in this document. 2.0 PURPOSE The purpose of the RMS is to provide radon mitigation contractors with uniform standards that will ensure quality and effectiveness in the design, installation, and EPA Radon evaluation of radon mitigation systems in detached and attached residential buildings three stories or less in height. 

The RMS is intended to serve as a model set of requirements which can be adopted or modified by state and local jurisdictions to fulfill objectives of their specific radon contractor certification or EPA Radon licensure programs. PARTICIPANTS Minimum requirements are established in the RMS for individuals nationwide who perform radon remediation work and wish to participate in the RCP Program. 

To participate in EPA's RCP Program, the mitigation contractor shall have completed all RCP training and examination requirements, be listed in the current RCP Listing Report, and EPA Radon shall agree to follow the provisions of the RMS. 4.0 SCOPE The requirements addressed in the RMS include the following categories of contractor activity: 

General Practices, Building Investigation, Worker Health and Safety, Systems Design, Systems Installation, Materials, Monitors and Labeling, Post-Mitigation Testing, and Contracts and EPA Radon Documentation. ASSUMPTION Before applying the provisions of the RMS, it is assumed that appropriate radon/radon decay product measurements have been performed within the structure, and that the owner has decided that radon remediation is necessary. 

IMPLEMENTATION 6.1 The RMS includes requirements for installation of radon remediation systems and provides a basis for evaluating the quality of those installations. It may be adopted by state EPA Radon regulatory agencies for state or local radon mitigation contractor licensure programs. It may also be used as a reference during inspection of in-progress or completed radon mitigation work. 

Contractors shall personally conduct follow-up inspection of any radon mitigation systems installed by their firm or by subcontractors to insure conformance with the EPA Radon requirements of the RMS. This requirement shall include the post-mitigation testing prescribed in paragraph 17.0. 6.3 EPA will evaluate reports of non- compliance with the RMS that are referred to the Agency by states and other agencies that monitor radon mitigation services. 

Based on its evaluation, EPA may initiate established RCP program de-listing procedures against contractors that the Agency or States (with certification programs) find are in violation of the mandatory EPA Radon provisions of the RMS (See paragraph 6.4). In addition, EPA or its agent may conduct inspections of radon mitigation projects. 

State radon program personnel or their contracted representatives are considered EPA agents for conducting such inspections. 6.4 Those EPA Radon provisions of the RMS that are considered to be mandatory are prefaced by the term "shall." Provisions that are considered good practice but which are not mandatory are prefaced by the terms "should" or "recommended." 6.5 

The RMS will be updated as necessary, and in response to technological advances and field experience. 7.0 LIMITATIONS 7.1 Although the provisions of the RMS have been carefully reviewed for potential conflicts with other regulatory requirements, EPA Radon adherence to the RMS does not guarantee compliance with the applicable codes or regulations of any other Federal, state, or local agency having jurisdiction. 

Where discrepancies exist between provisions of the RMS and local codes or regulations, local codes shall take precedence. However, EPA Radon where compliance with local codes necessitates a deviation from the RMS, EPA recommends that RCP listed contractors report the deviation in writing to the appropriate EPA Regional Office and the appropriate state regulatory official within 30 days. 

It should be noted that EPA is not requiring the EPA Radon reporting that is recommended in this paragraph. States with radon contractor certification programs may require that contractors give prior notification of their intent to deviate from the RMS for research or other purposes.

Standard Reference Guide For Professional Mold R

States with plans approved by STANDARD & REFERENCE GUIDE FOR PROFESSIONAL MOLD REMEDIATION under section 18(b) of the OSH Act must adopt standards and enforce requirements that are at least as effective as federal requirements. There are currently 26 state plan states: 22 of these administer pla  read more..

How To Repair Fire And Water Damage

Five members of Congress were recognized this month by the National Fire Protection Association (NFPA) for their exemplary work relating to fire service activities.Honored as NFPA Legislator of the Yearfor distinguished achievements from last year were Congressman Bob Etheridge of North Carolina; Co  read more..

OSHA Requirements For Crime Scene Death Cleanup

A common theme among the commenters concerned with home health care is the environment in which the care must be rendered. For example, one group stated: ... Unlike other types of providers, home health agencies (HHAs) do not control the worksite. Crime Scene Cleanup OSHA Requirements For Crime Scene Death Cleanup The worksite is the patient's home; t  read more..

Water Extraction

Mold Remediation Water Extraction is a natural bacterial component to our environment. It is essentially in the breaking down of dead organic materials (plants and trees and such) in nature.. BUT we do not want these to be present in our homes as some of them have potential to be harmful to our health. Mold starts as a s  read more..

Storm Damage

Woods are a byproduct of nature showing many inconsistencies. Cross-sectional (transverse) shrinkage isn’t always uniform. The quantity of shrinkage happening parallel with progress rings (tangential directions) ranges from one and one-half to two times as much as across, or at ninety d  read more..

Water Leak Detector

Leaking plumbing fixtures within homes can cause high water bills, excessive loss of water, and increased flow to the sewer system. Toilets Many leaks occur in toilets and may not be immediately recognized since there is no visible sign of a leak. Leaks in toilets can occur at the overflow pipe   read more..

Lead Paint Poisoning In Children

Physical examination should emphasize the neurological, gastrointestinal, and cardiovascular systems. The worker's weight and blood pressure should be recorded and the oral mucosa checked for pigmentation characteristic of a possible Burtonian or lead line on the gingiva.It should be noted, however,  read more..

How To Repair Fire Damaged Concrete

Recovering from a fire can be a physically and mentally draining process.When fire strikes, lives are suddenly turned around. Often, Fire Damage How To Repair Fire Damaged Concrete the hardest part is knowing where to begin and who to contact.

The U.S. Fire Administration has gathered the following information to assist you in  read more..

Painters Exposure To Lead Paint

The California Painters Project was a 2-year intervention research project aimed at preventing lead poisoning among a group of residential and commercial painters in San Francisco, Calif. As part of this project 12 contractors invited project staff to conduct employee Lead Paint Removal Painters Exposure To Lead Paint exposure monitor  read more..

Will Using Dehumidifier Get Rid Of Mold In A Room

In addition to correctly installing a vapor barrier, it is important to provide adequate ventilation of spaces where moisture can build up. Most building codes require that attics and crawl spaces be ventilated, Dehumidification Will Using Dehumidifier Get Rid Of Mold In A Room and some require a minimum one-inch clear airspace above the insulation for ve  read more..