RADON MITIGATION STANDARDS 1.0 BACKGROUND The 1988 Indoor Radon Abatement Act (IRAA) required the Environmental Protection Agency (EPA) to develop a voluntary program to evaluate and provide information on contractors who offer radon control services to homeowners. The Radon Contractor Proficiency (RCP) Program was established to fulfill this EPA Radon portion of the IRAA. 

In December 1991, EPA published "Interim Radon Mitigation Standards" as initial guidelines for evaluating the performance of radon mitigation contractors under the RCP Program. Over the past six years, EPA Radon the effectiveness of the basic radon mitigation techniques set forth in the, "Interim Standards" has been validated in field applications throughout the United States. 

This experience now serves as the basis for the more detailed and final Radon Mitigation Standards (RMS) set forth in this document. 2.0 PURPOSE The purpose of the RMS is to provide radon mitigation contractors with uniform standards that will ensure quality and effectiveness in the design, installation, and EPA Radon evaluation of radon mitigation systems in detached and attached residential buildings three stories or less in height. 

The RMS is intended to serve as a model set of requirements which can be adopted or modified by state and local jurisdictions to fulfill objectives of their specific radon contractor certification or EPA Radon licensure programs. PARTICIPANTS Minimum requirements are established in the RMS for individuals nationwide who perform radon remediation work and wish to participate in the RCP Program. 

To participate in EPA's RCP Program, the mitigation contractor shall have completed all RCP training and examination requirements, be listed in the current RCP Listing Report, and EPA Radon shall agree to follow the provisions of the RMS. 4.0 SCOPE The requirements addressed in the RMS include the following categories of contractor activity: 

General Practices, Building Investigation, Worker Health and Safety, Systems Design, Systems Installation, Materials, Monitors and Labeling, Post-Mitigation Testing, and Contracts and EPA Radon Documentation. ASSUMPTION Before applying the provisions of the RMS, it is assumed that appropriate radon/radon decay product measurements have been performed within the structure, and that the owner has decided that radon remediation is necessary. 

IMPLEMENTATION 6.1 The RMS includes requirements for installation of radon remediation systems and provides a basis for evaluating the quality of those installations. It may be adopted by state EPA Radon regulatory agencies for state or local radon mitigation contractor licensure programs. It may also be used as a reference during inspection of in-progress or completed radon mitigation work. 

Contractors shall personally conduct follow-up inspection of any radon mitigation systems installed by their firm or by subcontractors to insure conformance with the EPA Radon requirements of the RMS. This requirement shall include the post-mitigation testing prescribed in paragraph 17.0. 6.3 EPA will evaluate reports of non- compliance with the RMS that are referred to the Agency by states and other agencies that monitor radon mitigation services. 

Based on its evaluation, EPA may initiate established RCP program de-listing procedures against contractors that the Agency or States (with certification programs) find are in violation of the mandatory EPA Radon provisions of the RMS (See paragraph 6.4). In addition, EPA or its agent may conduct inspections of radon mitigation projects. 

State radon program personnel or their contracted representatives are considered EPA agents for conducting such inspections. 6.4 Those EPA Radon provisions of the RMS that are considered to be mandatory are prefaced by the term "shall." Provisions that are considered good practice but which are not mandatory are prefaced by the terms "should" or "recommended." 6.5 

The RMS will be updated as necessary, and in response to technological advances and field experience. 7.0 LIMITATIONS 7.1 Although the provisions of the RMS have been carefully reviewed for potential conflicts with other regulatory requirements, EPA Radon adherence to the RMS does not guarantee compliance with the applicable codes or regulations of any other Federal, state, or local agency having jurisdiction. 

Where discrepancies exist between provisions of the RMS and local codes or regulations, local codes shall take precedence. However, EPA Radon where compliance with local codes necessitates a deviation from the RMS, EPA recommends that RCP listed contractors report the deviation in writing to the appropriate EPA Regional Office and the appropriate state regulatory official within 30 days. 

It should be noted that EPA is not requiring the EPA Radon reporting that is recommended in this paragraph. States with radon contractor certification programs may require that contractors give prior notification of their intent to deviate from the RMS for research or other purposes.

Water Damage

My tenants just moved out and did not inform me of Tenant Move Out Cleanup Water Damage. When I went in I discovered my carpets were all wet. The water at been shut off so I do not know where the water is coming from. What do I do? First one must start by contacting an expert in flood damage  read more..

How Do I Get Help For Animal Hoarding

This study issue was suggested by Council member Moylan at the November 29, 201 1 City Council meeting. It was proposed after staff presented RTC number 11-253 "Proposed Ordinance Allowing Neighborhood Preservation to More Effectively Address Blighted and Vacant Properties." The proposed ordinance p  read more..

How To Repair Cracked Circuit Boards

The abrasive and mildly corrosive nature of ash can damage computer and electronic systems. When possible, the best damage-preventive strategy is to shut down all computer, electric motors, and electronic systems until the ash has been completely removed from the equipment and the surrounding area,   read more..

How To Remove Hurricane Damage Debris

More advanced tracking tools have been developed and used in the field to reduce human error and expedite funding. These computer-based systems often include the same information as a traditional load ticket. Each monitor is responsible for populating specific areas of the load ticket. The following  read more..

How To Start A Business Cleaning Trash Out Of For

Using a charge or threat of criminal trespass against tenants in order to evict them without the benefit of a court hearing is an abuse of the law. Police who participate in such an action may be guilty of official misconduct.108 In such cases, Tenant Move Out Cleanup How To Start A Business Cleaning Trash Out Of For tenants may sue both the landlord and th  read more..

Health Risks From Lead Paint

Zinc protoporphyrin results from the inhibition of the enzyme ferrochelatase which catalyzes the insertion of an iron molecule into the protoporphyrin molecule, which then becomes heme. If iron is not inserted into the molecule then zinc, having a greater affinity for protoporphyrin, takes the place  read more..

How To Restore Smoke Damaged Archive Photos

If the repository chooses not to use one of the tools cited above, these following questions will help to establish the enduring research or Document restoration How To Restore Smoke Damaged Archive Photos educational value of a collection or a publication in terms of institutional priorities and the overall documentation available on the topic covered:   read more..

Radon In Homes

Introduction Lung cancer's very high associated mortality rate is even more tragic because a significant portion of lung cancer is preventable. While smoking remains the number one cause of lung cancer, Radon Mitigation Radon In Homes presents a significant second risk factor. That is why, in addition to encouraging patients   read more..

Electrical Systems In Flood damaged Buildings

Question: Do electrical systems and equipment submerged through flooding have to be replaced? Answer: Floodwaters are not just water; the water may also be contaminated with chemicals, sewage, oil and other debris. When the floodwater is salt water, its corrosive effects are particularly damaging. A  read more..

Water Removal

Most of our building codes require the use of crawlspace vents to help in removing moisture from the ME. But, many home construction professionals are now realizing that an unvented crawlspace or a closed crawlspace vents only after the crawlspace has had a chance to dry out after the initial  read more..