Radon Mitigation >> Radon Testing

Heat Recovery Ventilation (HRV) systems shall not be installed in rooms that contain friable asbestos. 14.8.4 In HRV installations, supply and exhaust ports in the interior shall be located a minimum of 12 feet apart. The exterior supply and exhaust ports shall be positioned to avoid blockage by snow or leaves Radon Testing and be a minimum of 10 feet apart. 

Contractors installing HRV systems shall verify that the incoming Radon Testing and outgoing airflow is balanced to ensure that the system does not create a negative pressure within the building. Contractors shall inform building owners that periodic filter replacement and inlet grill cleaning are necessary to maintain a balanced airflow. 

This information shall also be included in the documentation. 14.8.6 Both internal and external intake Radon Testing and exhaust vents in HRV systems shall be covered with wire mesh or screening to prevent entry of animals or debris or injury to occupants. 15.0 MATERIALS 15.1 All mitigation system electrical components shall be U.L. listed or of equivalent specifications. 

As a minimum, all plastic vent pipes in mitigation systems shall be made of Schedule 20 PVC, ABS or equivalent piping material. Schedule 40 piping or its equivalent should be used in garages and in other internal and external locations subject to weathering or physical damage. 15.3 Vent pipe fittings in a mitigation system shall be of the same material as the vent pipes. 

(See paragraph 14.3.7 for exception when installing vent fans, and paragraph  for exception when installing radon vent pipes in sump pit covers. Cleaning solvents and adhesives used to join plastic pipes Radon Testing and fittings shall be as recommended by manufacturers for use with the type of pipe material used in the mitigation system. 

When sealing cracks in slabs and other small openings around penetrations of the slab and foundation walls, caulks Radon Testing and sealants designed for such application shall be used. Urethane sealants are recommended because of their durability. 

When sealing holes for plumbing rough-in or other large openings in slabs and foundation walls that are below the ground surface, non-shrink mortar, grouts, expanding foam, Radon Testing or similar materials designed for such application shall be used. 15.7 Sump pit covers shall be made of durable plastic or other rigid material and designed to permit air-tight sealing. 

To permit easy removal for sump pump servicing, the cover shall be sealed using silicone or other non-permanent type caulking materials or an air-tight gasket. 15.8 Penetrations of sump covers to accommodate electrical wiring, water ejection pipes, Radon Testing or radon vent pipes shall be designed to permit air-tight sealing around penetrations, using caulk or grommets. 

Sump covers that permit observation of conditions in the sump pit are recommended. Plastic sheeting installed in crawlspaces as soil-gas retarders shall be a minimum of 6 mil (3 mil cross-laminated) polyethylene or equivalent flexible material. Heavier gauge sheeting should be used when crawlspaces are used for storage, Radon Testing or frequent entry is required for maintenance of utilities. 

Any wood used in attaching soil-gas retarder membranes to crawlspace walls or Radon Testing piers shall be pressure treated or naturally resistant to decay and termites. 16.0 MONITORS AND LABELING 16.1 All active soil depressurization and block wall depressurization radon mitigation systems shall include a mechanism to monitor system performance and warn of system failure. 

The mechanism shall be simple to read or interpret and be located where it is easily seen or heard by building occupants and protected from damage or Radon Testing destruction. Electrical radon mitigation system monitors (whether visual or audible) shall be installed on non-switched circuits and be designed to reset automatically when power is restored after service or power supply failure. Battery operated monitoring devices shall not be used unless they are equipped with a low-power warning feature.

Get Rid Of Radon Out Of Your Home

Individuals and organizations submitting long-term devices within methods such as EL, AT, and some RP are expected to give EPA complete Radon Mitigation Get Rid Of Radon Out Of Your Home information on their lower limit of detection in (pCi/L)-days, as well as the maximum permissible exposure level upon request. EPA will work with device manufa  read more..

Get Rid Of Mold And Mildew In The Crawl Space Under A Mobile Home

Most building codes require crawlspace vents to aid in removing moisture from the crawlspace. However, many building professionals are now recognizing that an unvented crawlspace (or closing crawlspace vents after the crawlspace has had time to dry out after construction) is the best option in homes  read more..

Lead Paint Removal Programs

Employers must instruct each physician not to reveal to the employer in writing or in any other way his or her findings, laboratory results, or diagnoses which are felt to be unrelated to occupational lead exposure. They must also instruct each physician to advise the employee of any occupationally   read more..

Basement Drying

Unprotected building occupants and water restoration workers should be evacuated from the Sewage Cleanup Basement Drying affected areas during the beginning stages of decontamination, sewage cleaning, and disinfection, such as until the sewage has been completely removed and the disinfectants applied. The water restor  read more..

OSHA Lead Paint In Construction Standard

In the OSHA Lead in Construction Standard, manual sanding is listed as a work method that, in the absence of previous exposure data, is initially presumed to expose employees to lead in excess of 50 mg/m3 but not in excess of 500 mg/m3 . However, the arithmetic mean for the nine 30-min exposures in   read more..

Radon Reduction

Houses with water management systems such as basement sump pumps, French style drains, or an exterior loop of buried water-collection tuning could be efficiently mitigated by attaching the active soil depressurization method system to the existing water management system. A Radon Mitigation Radon Reduction system fan an  read more..

Carpet Stain Removal Tips

Structural drying is an important step in the chain of work concerned with lumber scheming. Not, only should the worker be familiar with structural drying procedures and equipment employed, he, ought to become acquainted with the traits of the lumber with which he is concerned in correlation to sche  read more..

Flood Insurance Rate Map

Zone AO: Areas subject to inundation by 1-percent-annual-chance shallow flood insurance rate map (usually sheet flow on sloping terrain) where average depths are 1–3 feet. Average Flood Damage Flood Insurance Rate Map depths derived from detailed hydraulic analyses are shown within this zone. Mandatory flood insurance rate map ins  read more..

Prevent Radon Gas

Participants in the Residential Measurement Service Provider component of the RPP must earn a minimum of eight (8) of the required sixteen (16) hours of continuing education every two years through approved Category I course work. Those with dual listings are required to earn a minimum of sixteen (1  read more..

How To Rebuild Fire Damaged Homes

Pressure wash, scrub or disinfect all exterior surfaces including walls, walks, drives, decks, window and Fire Damage How To Rebuild Fire Damaged Homes deck screens, etc. Wash and disinfect all interior walls and hard surfaces with mild soap or other appropriate cleaning solutions or products, and rinse thoroughly.

Don't   read more..