Flood Damage >> Dehumidification

Cracks from flood damage that cause foundation erosion, however, this can be expected to worsen over time as your building settles slowly to its new soil support point. The best Dehumidification indicator of this type of structural problem is foundation cracks that move. Movement, particularly the widening of cracks, this is a sign of structural instability warranting careful foundation examination by a qualified structural damage engineer or architect.

  1. The best way to the side whether a foundation crack is moving is to purchase a device that is called a "tell-tale." This small gauge is glued to a Dehumidification wall on either side of a foundation crack. Its markings will indicate the wall crack's horizontal and vertical movement over time. Another good way to determine whether movement actually exists is to glue a glass microscope slide across a foundation crack. If the glass slide breaks, foundation movement is occurring. Water damage may erode the soil adjacent to the edge of your building.
  2. This could lead to two problems, first the soil may be "dished" next to your building which could result in additional water damage from future rain. The Dehumidification soil that is adjacent to the building should slope away from its side to ensure that future rains do not drain inside the building. Once the floodwaters subside, check all of the soil drainage patterns and re-grade as necessary. A far less common soil problem is the loss of enough dirt to protect your foundation walls from frost-heaving during the cold weather. If the Dehumidification foundation is not buried sufficiently below the frost line, it may heave upward when the loose ground beneath it freezes.
  3.  And for this reason, it is always best to replace any lost dirt from a flood, adjacent to the building foundation. Erosion could also affect the paving. From your building’s conservation perspective, the worst possible problem occurs when the eroded slabs of asphalt or concrete channel flood water into, rather than away from your building. As with soil erosion, this could lead to water problems from the future rains. If this Dehumidification condition exists, the concrete slab should either be raised (by mudjacking, for example) or it should be removed and replaced with a slab that drains properly.
  4. With very few exceptions, any building insulation that has been immersed in flood water should be removed for two reasons, first after being completely saturated, most building insulation is rendered permanently ineffective, particularly loose-fill types, such as cellulose, vermiculite, rock wool, and blown fiberglass insulation, which can tend to collapse under their own weight. And second, saturated insulation holds the water which, if left in place, can perpetuate high excessive moisture conditions that is destructive to wood, masonry, and most steel. Some types of building insulation may be left in place after a Dehumidification contact, such as closed-cell styrene and all urethane board insulations that do not absorb flood water. These should be inspected to decide whether or not they hold moisture against the wood or masonry building materials or steel fasteners.

How To Measure Radon Levels

EPA Recommends the Following Testing Steps:Step 1.Take a short-term test. If your result is 4 pCi/L or higher, take a follow-up test (Step 2) to be sure.Step 2. Follow up with either a long-term test or a second short-term test: For a better understanding of your year-round average radon level, Radon Mitigation How To Measure Radon Levels  read more..

How To Clean Up Cigarette Smoke Odor

Saitoh and Inukai contend that humidity is probably the most important factor in determining the amount of corrosion that occurs [80]. They also note that the combustion gases from materials such as wood and asphalt that are not expected to produce HCl still produce corrosion. They surmise the prese  read more..

Asbestos Flooring

Question 1: Are we correct that Asbestos Abatement Asbestos Flooring floor tile cleaning activities (normal maintenance such as stripping and buffing operations) are covered under both the Asbestos flooring General Industry Standard (§1910.1001) and the Asbestos flooring Construction Standard (§1926.1101)?  <  read more..

Finding The Water Leak

Guidance for Food Establishments for Re-opening After Flooding Sept. 9, 2011 This information is for licensed food and/or lodging establishments. Take the following actions to re-open after damage to your facility and food stocks due to flooding and Water Damage Finding The Water Leak power outages.

  read more..

Surviving A Tornado

Risk Assessment: Wind/Tornadoes Description The term "straight-line winds" is used to distinguish common, non-rotating winds from tornado-related winds. Straight-line winds are responsible for most thunderstorm wind damage, Wind Damage Surviving A Tornado with wind speeds in excess of 100 miles per hour on occasion.  read more..

Chrysotile

Abstract This review provides a basis for substantiating both kinetically and pathologically the differences between chrysotile and amphibole asbestos. 
Chrysotile, which is rapidly attacked by the acid environment of the macrophage, falls apart in the lung into short fibers and particles  read more..

Radon Test

Radon is a highly radioactive, colorless, odorless, and tasteless gaseous substance, it is formed as the natural deposits of thorium and uranium throughout the earth’s crust decaying process. As the Radon Mitigation Radon Test decay products are unknowingly inhaled, they could alter the cells in your lungs. T  read more..

Tree Removal From Hurricane Damage

This office reported that its applicants had "passed every decision through layers of FEMA approvals" at the time the original disaster cleanup was under way, and it was only informed years later that certain vegetative debris removal was ineligible for reimbursement. Several applicants have encount  read more..

Dehumidification

The very first step in any water damaged document restoration is to document very item and categorize them to resemble some kind of system. To assist in the documentation  step is good to light and separate dry, damp and water soaked documents. Upon the recommendation of the supervisor overs  read more..

Smoke Damage From A House Fire

Damaged, or "mutilated" currency may be mailed or personally delivered to the Bureau of Engraving and Printing. When mutilated currency is submitted, a letter should be included stating the estimated value of the currency and an explanation of how the currency became mutilated. Each case is carefull  read more..