Lead Paint Removal >> Lead Dust Protection

HOW TO USE HALF-MASK RESPIRATORS TO PREVENT LEAD POISONING Half-mask air-purifying respirators are cheap and easy to take care of. They prevent lead poisoning by protecting the wearer from breathing lead-containing dust or smoke ("fume"). These respirators cannot protect against very high levels of lead, Lead Dust Protection but they do provide enough protection for many industrial and construction workers. 

This guide covers the basics of good respirator use and Lead Dust Protection the main Cal/OSHA requirements. Page 4 of the guide contains phone numbers you can call for further assistance. NOT EVERYONE CAN WEAR A RESPIRATOR Respirators can put too much stress on the heart and lungs for some people. Employers should pay for a medical evaluation first to see if workers can safely wear a respirator. 

This is especially important for smokers, people with heart or lung trouble, and Lead Dust Protection anyone who has difficulty breathing when wearing a respirator. Respirators may not be needed if you can reduce air lead levels by changing work practices, changing tools, or using local exhaust ventilation. Cal/OSHA requires that employers reduce high air lead levels (50 µg/M3 or higher) using these basic controls where possible. 

Respirators can be used until you have made these changes, and then afterwards if added protection is still needed. USE THE CORRECT RESPIRATOR FILTERS Use P-100, R-100, or Lead Dust Protection N-100 respirator filters to protect against lead. These used to be called HEPA filters. Where oil mists are also present, be sure to use P-100 filters. 

Different filters are required for other toxic substances. A RESPIRATOR MUST FIT WELL TO PROTECT WELL. SELECT SIZE AND SHAPE. Like shoes, respirators come in different shapes and sizes. A respirator has to fit well to provide good protection. Respirator size and Lead Dust Protection shape should be selected to fit snugly but comfortably. Shake your head. 

The respirator should stay in place. TEST THE RESPIRATOR FIT Cal/OSHA requires that the employer test the fit of the respirator. There are two kinds of fit tests. Both test how much the respirator leaks around the face seal. The "qualitative" fit test is simple and inexpensive to do. A testing chemical with a strong smell or Lead Dust Protection taste is released around the respirator face seal. 

If the wearer can smell or taste the chemical, Lead Dust Protection the respirator has failed the fit test. The "quantitative" fit test uses electronic equipment to measure how much the respirator leaks. The advantage of this test is that it tells you how well the respirator fits. This allows you to compare different respirators and select the one that fits best. 

ALWAYS CHECK THE FACE SEAL It is important to do a "user seal check" every time you put on a respirator. Getting into the Lead Dust Protection habit is the best thing a wearer can do to ensure good protection. Negative Seal Check Cover the filters so that air cannot be drawn through them. Collapse the mask against your face by inhaling gently. 

Hold your breath for 10 seconds. If air leaks in and the mask reinflates, check the valves, adjust the straps and try again. If air does not leak in and the mask stays collapsed against your face, Lead Dust Protection it has passed the negative face seal check. Positive Seal Check Cover the exhalation valve with the palm of your hand.  

Inflate the mask slightly by exhaling gently. Wait a few seconds. If air leaks out and the mask deflates, check the valves, adjust the straps Lead Dust Protection and try again. If the face seal holds the air and the mask stays inflated, it has passed the positive face seal check. A HALF-MASK RESPIRATOR DOES N0T ALWAYS PROVIDE ENOUGH PROTECTION. 

Half-mask respirators leak too much to protect against very high levels of lead. A half-mask offers good protection only if the amount of lead in the air around the worker is less than 500 micrograms per cubic meter of air (500 µg/M3). To find out how much lead workers are exposed to, Lead Dust Protection Cal/OSHA requires that employers do "personal air sampling." 

Note: Half-mask air-purifying respirators do not protect the wearer in areas where there is not enough oxygen. General Industry Until good local exhaust ventilation is installed, Lead Dust Protection half-mask respirators generally provide enough protection for the following tasks: Automotive radiator repair Spraying lead glaze or paint  

Casting and machining lead-containing metals Construction According to Cal/OSHA, Lead Dust Protection if you are working on surfaces coated with lead paint, half-mask respirators probably provide enough protection for the following tasks: Manual demolition Hand sanding and scraping Heat gun use HEPA vacuum-attached power sanding For these tasks start with half-mask respirators, then do air sampling to make sure that the air levels are not above 500 µg/M3. 

Start with a more protective respirator if you are doing work that creates more dust or Lead Dust Protection fume such as power sanding, abrasive blasting, welding or torch cutting. Respirators come with the manufacturer's recommendations for maintenance and care. Here are a few tips: Clean respirators at the end of the day. 

Wash your hands first. Remove the filters and Lead Dust Protection wipe clean if possible. Change the filters as soon as you notice it is slightly harder to breathe through them. The respirator mask should be washed with a mild detergent in warm water, and then rinsed well. If there is no water available, use disposable towelettes such as baby-wipes. Dry the respirator before storing it.  

Store the respirator in a rigid plastic container. Plastic containers commonly used for food left-overs are perfect for storing half-mask respirators. The filters should be stored in a resealable plastic bag and Lead Dust Protection placed in the container. Regularly inspect the respirator and replace worn or damaged parts. 

The wearer or an assigned person should regularly inspect the respirator and replace worn or damaged parts. Replacement parts for half-mask respirators are inexpensive and Lead Dust Protection should be stocked on-site. MAKE SURE EMPLOYEES ARE TRAINED Cal/OSHA requires that employers train employees in how respirators work, how to wear them, and how to take care of them.

Animal Removal

Think about it, if you were an animal, where would you rather live, outdoors dealing with the elements, or indoors where it's nice, safe and warm. Animals outdoors are cute furry creatures, but indoors, they can be very destructive and downright dangerous. Houses that have endured Animal Damage Animal Removal, h  read more..

Lead Paint Abatement

Are the employer acts pursuant to a final medical determination which permits the return of the employee to his or her former job status despite what would otherwise be an unacceptable blood lead level, later questions concerning removing the Lead Paint Removal Lead Paint Abatement employee again shall be decided by a final  read more..

Safely Get Water Out Of A Flooded Basement

Reinforce walls and footings to minimize shrinkage cracking and cracking due to uneven settlement. To retard movement of radon through hollow core masonry walls, the top and bottom courses of hollow masonry walls should be solid block, Basement Drying Safely Get Water Out Of A Flooded Basement or filled solid. 

  read more..

Hurricane Safety Procedures

The contractor must submit drawings to DCAM through the Department or Agency for approval of any windows or openings to be sealed by any method other than that shown in sketches listed in number 1 above.9. For windows over 48 inches wide or 96 inches in height, the contractor must submit drawings to  read more..

How To Fix A Wet Crawl Space From Mold

Set your home's thermostat at the coolest level you can without making your rooms uncomfortable. For most homes, the heating bill drops by about 2 percent for every 1 degree the thermostat is lowered. Crawl Space Drying How To Fix A Wet Crawl Space From Mold Lower your home's thermostat at bedtime or while you're away during the day.     read more..

Black Mold Exposure

Although the largest group of patients had diffuse pulmonary infiltrates, a significant fraction had focal pulmonary disease, meningitis, Mold Remediation Black Mold Exposure or other extrapulmonary disease. Six patients had only a positive serologic test with no other evidence of infection. Excluding the patients who ha  read more..

How To Remove Smoke Odor From A Kitchen Fire

Comparison of Fire Performance and Corrosion Work by Chapin et al. [25] evaluated the ability of a variety of standard test methods to evaluate the impact of smoke from local area network (LAN) cables on electrical equipment. Their concern was that the specialized and controlled nature of these test  read more..

How To Get Rid Of A Smoke Smell In A House After A

Do not enter the damaged site until the Bryan Fire Department gives you the OK. Fires can re-ignite from hidden, smoldering remains. Normally, the fire department will see that utilities (water, electricity and natural gas) are either safe to use or are disconnected before they leave the site. Do no  read more..

Complete Remodal From Tenant Trash

Landlords have the right to copies of all keys, as well as instructions on how to operate burglary or fire prevention devices added by the tenant. Before changing or adding locks or installing any devices, tenants should get the landlord's written permission Tenant Move Out Cleanup Complete Remodal From Tenant Trash and approval. 
  read more..

About Radon Radon Myths

Radon Myths MYTH: Scientists aren't sure radon really is a problem. FACT: Although some scientists dispute the precise number of deaths due to radon, all the major health organizations (like the Centers for Disease Control and Prevention, Radon Mitigation About Radon Radon Myths the American Lung Association and the American  read more..