Asbestos Abatement >> Vermiculite Insulation

Protect Your Family from Vermiculite Insulation Asbestos-Contaminated Vermiculite insulation Insulation This page provides important information on how to protect yourself and your family if you suspect that you might have vermiculite insulation from Libby, Montana. What is Vermiculite insulation 

Vermiculite insulation is a naturally-occurring mineral composed of shiny flakes, resembling mica. When heated to a high temperature, flakes of vermiculite insulation expand as much as 8-30 times their original size. 

The expanded vermiculite insulation is a light-weight, fire-resistant, and odorless material and has been used in numerous products, including insulation for attics and walls. Sizes of vermiculite insulation products range from very fine particles to large (coarse) pieces nearly an inch long. Concerns about Asbestos-contaminated Vermiculite insulation Insulation 

A mine near Libby, Montana, was the source of over 70 percent of all vermiculite insulation sold in the United States from 1919 to 1990. There was also a deposit of asbestos at that mine, Vermiculite Insulation so the vermiculite insulation from Libby was contaminated with asbestos. 

Vermiculite insulation from Libby was used in the majority of vermiculite insulation insulation in the United States and was often sold under the brand name Zonolite. If you have vermiculite insulation insulation in your home, you should assume this material may be contaminated with asbestos and Vermiculite Insulation be aware of steps you can take to protect yourself and your family from exposure to asbestos. 

Identifying Insulation That is Made From Vermiculite insulation Look at the photos on this website and then look at the insulation without disturbing it. Vermiculite insulation insulation is a pebble-like, pour-in product and Vermiculite Insulation is usually gray-brown or silver-gold in color. The following photographs show typical vermiculite insulation insulation. 

You should assume that vermiculite insulation insulation is from Libby and treat the Vermiculite Insulation material as if it contained asbestos by not disturbing it or by using a trained professional if it needs to be removed. 

Since the Libby mine was estimated to be the source of over 70 percent of all vermiculite insulation sold in the United States from 1919 to 1990 and vermiculite insulation from Libby was contaminated with asbestos, further Vermiculite Insulation testing is not necessary to take the appropriate precautions. 

While you can hire a trained professional to test your attic for asbestos, this may be expensive and, depending on the methods used, Vermiculite Insulation might give you erroneous results. We do not recommend that you open your walls to check for vermiculite insulation. Risk of Exposure to Asbestos If You Have Vermiculite insulation Insulation Asbestos causes cancer and other diseases. 

There is no known safe level of asbestos exposure. Asbestos fibers must be airborne to cause a health risk through Vermiculite Insulation inhalation, so the first step is not to disturb the material, which would release more fibers into the air. 

If you remove or disturb the insulation, it is probable that you may inhale some asbestos fibers - the degree of health risk depends on how much and how often this occurred. If you do not go into your attic, handle, or disturb the insulation, it is likely that you will not be exposed to Vermiculite Insulation asbestos fibers from vermiculite insulation insulation. 

Also, you need to consider if any disturbance of the insulation - possibly by a contractor doing work in your Vermiculite Insulation attic - may result in the fibers being deposited into other areas of your house where an exposure might be possible. Concerns About Exposure If Your Family Removed or Handled Insulation That Contained Asbestos 

It is not possible to say whether your exposure may result in disease. Exposure to Vermiculite Insulation asbestos increases your risk of developing lung diseases including asbestosis, lung cancer, or mesothelioma, and disease may not occur until decades after exposure. The risk of disease increases as the level, duration, and frequency of exposure increases. 

That risk is made worse by smoking. If you are concerned about possible exposure, talk to your doctor and consider consulting a physician who specializes in lung diseases, Vermiculite Insulation also known as a pulmonologist. For more information on asbestos-related diseases see the Agency for Toxic Substances & Disease Registry Web site. 

If You Have Vermiculite insulation Insulation YOU SHOULD ASSUME THE VERMICULITE INSULATION CONTAINS ASBESTOS AND DO NOT DISTURB IT! Any disturbance could potentially release Vermiculite Insulation asbestos fibers into the air. 

If you absolutely have to go in your attic and it contains vermiculite insulation insulation, you should limit the number of trips you make and Vermiculite Insulation shorten the length of those trips in order to help limit your potential exposure. We recommend that you: Leave vermiculite insulation insulation undisturbed in your attic or in your walls. 

Do not store boxes or Vermiculite Insulation other items in your attic if it contains vermiculite insulation insulation. Do not allow children to play in an attic with vermiculite insulation insulation. Do not attempt to remove the insulation yourself. 

Hire a professional asbestos contractor if you plan to remodel or conduct renovations that would disturb the vermiculite insulation in your attic or Vermiculite Insulation walls to make sure the material is safely handled and/or removed.

Hurricane Flooding Facts

Do I need the Hepatitis A vaccine?There is no indication for the Hepatitis A vaccine given the anticipated conditions in the region Water Damage Hurricane Flooding Facts and low probability of exposure. No transmission from contaminated water has been identified in the U.S. since the 1980's. 

<  read more..

OSHA Regulations For Perimeter Fencing

The NHC official forecasts did outperform many of the individual intensity models.Only the GHMI (at the 96 and 120 h periods) and the FSSE (at the 72-120 h periods) had smaller errors than the official intensity forecasts. However, Emergency Board up OSHA Regulations For Perimeter Fencing the intensity model consensus (ICON)bested the offici  read more..

Bomb Cleanup

Regardless of meaningfully improved authority and state efforts to make sure that local administration are prepared for Debris Removal Bomb Cleanup processes, most local administrations are not well informed concerning the techniques they must follow to establish economical and guideline-compliant debris removal pr  read more..

FEMA Map

If my community is not participating in the CRS, what can I do to have my community join? The decision to join the CRS is a voluntary action of a community's elected officials. As with many community actions, citizens can contact their local elected officials and encourage the community to consider   read more..

How To Remove Smoke Odor

Identification and Preparation of Cleaner Air Shelters for Protection of the Public from Wildfire Smoke 1. Identify one or more facilities with tight-sealing windows and doors and public access (for example, public schools, fire stations, or hospitals). As a rule of thumb, Smoke Damage How To Remove Smoke Odor newer build  read more..

Roof Leak Repair Cost

As an option to securing the conductors with stripping plies, conductor connectors that do not rely on prongs (such as the one shown in Figure 6) could be used. However, because the magnitude of the dynamic loads induced by the conductor are unknown Structural Drying Roof Leak Repair Cost and because of the lack of data on   read more..

Leaking Toilet Base

Burst Pipe Floods Basement Areas On the front page...Late Tuesday evening, June 26, the Clinical Center experienced one of the worst floods in its history when a water booster pump vibration eliminator on a chilled- water pipe burst and ran for 40 minutes before it was detected Water Damage Leaking Toilet Base and st  read more..

Emergency Board Up

Plywood shutters that you create yourself, if placed correctly, could provide a high degree of Wind Damage Emergency Board Up coverage from flying debris during a storm. Plywood shutters could be placed on all kinds of houses. Measure every window and every door that has glass, and add 8 inches to all the height and w  read more..

Difficult Smoke Cleanup

Because of the scale of the project the usual solvent toxicity and flammability protection techniques were impractical or impossible. For this reason the solvent of choice was Freon 113 (Dupont), a solvent that is both non-flammable and relatively non-toxic. 4.1 PROCEDURE FOR APPLYING POULTICE Appro  read more..

Mold Remediation

Meth Lab Cleanup Mold Remediation, that are used to make the unlawful drug methamphetamine, are found manufacturing in houses, rented apartments, motel rooms, side sheds, and even motor vehicles. Federal, state and local law enforcement were credited in the appropriation of thousands of meth labs across the country, and   read more..