Places that are often or always damp can be hard to maintain completely free of mold. If there's some mold in the shower or elsewhere in the bathroom that seems to reappear, increasing ventilation (running a fan or opening a window) and cleaning more frequently will usually prevent mold from recurring, Mold Remediation From Colorado Flooding or at least keep the mold to a minimum. 

You may suspect hidden mold if a building smells moldy, but you cannot see the source. If you know there has been water damage and residents are reporting health problems. Mold may be hidden in places such as the back side of dry wall, wallpaper, or paneling, the top side of ceiling tiles, Mold Remediation From Colorado Flooding the underside of carpets and pads, etc. 

Other possible locations of hidden mold include areas inside walls around pipes (with leaking or condensing pipes), the surface of walls behind furniture (where condensation forms), inside ductwork, Mold Remediation From Colorado Flooding and in roof materials above ceiling tiles (due to roof leaks or insufficient insulation). Investigating hidden mold problems. 

Investigating hidden mold problems may be difficult and will require caution when the investigation involves disturbing potential sites of mold growth. For example, Mold Remediation From Colorado Flooding removal of wallpaper can lead to a massive release of spores if there is mold growing on the underside of the paper. If you believe that you may have a hidden mold problem, consider hiring an experienced professional. 

Biocides are substances that can destroy living organisms. The use of a chemical or biocide that kills organisms such as mold (chlorine bleach, Mold Remediation From Colorado Flooding for example) is not recommended as a routine practice during mold cleanup. There may be instances, however, when professional judgment may indicate its use (for example, when immune-compromised individuals are present). 

In most cases, it is not possible or desirable to sterilize an area; a background level of mold spores will remain - these spores will not grow if the moisture problem has been resolved. If you choose to use disinfectants Mold Remediation From Colorado Flooding or biocides, always ventilate the area and exhaust the air to the outdoors. Never mix chlorine bleach solution with other cleaning solutions or detergents that contain ammonia because toxic fumes could be produced. 

Dead mold may still cause allergic reactions in some people, Mold Remediation From Colorado Flooding so it is not enough to simply kill the mold, it must also be removed. Suspicion of hidden mold growing on the back side of wallpaper. If you choose to hire a contractor (or other professional service provider) to do the cleanup, make sure the contractor has experience cleaning up mold. 

Check references and ask the contractor to follow the recommendations in EP's Mold Remediation in Schools Mold Remediation From Colorado Flooding and Commercial Buildings, the guidelines of the American Conference of Governmental Industrial Hygenists (ACGIH), or other guidelines from professional or government organizations. 

If you suspect that the heating/ventilation/air conditioning (HVAC) system may be contaminated with mold (it is part of an identified moisture problem, for instance, or there is mold near the intake to the system), Mold Remediation From Colorado Flooding consult before taking further action. The occupied section of Floor 1 was not assessed (northeast corner- first suite to the left upon entering building at front door). 

The unleased suite directly to the south of Storeroom 103 had two areas with chillers that prevented the wall from being opened at these locations. All other areas on Floor 1 were assessed. All exterior wall areas seen in Mold Remediation From Colorado Flooding the walk through of Phase 3 have been satisfactorily cleaned with soap/detergent and water. 

Any evidence of previous mold growth on studs Mold Remediation From Colorado Flooding or plywood has been completely removed. There were two studs noted (Office 109 – southwest corner; DPL Staff Suite 108 – near southeast corner) that had a dappled appearance - as if mold had been growing on them in the past and discolored the wood. There did not appear to be active fungal growth on them now. 

Alborn Construction agreed they would soap/disinfect the two affected studs. The remainder of the first floor had Mold Remediation From Colorado Flooding occasional areas where the wood has been discolored over time- most likely due to prior water intrusion, sap leaching or lumber mill practices. 

Multiple readings in various areas throughout the suites with a protimeter (wood moisture reading device) showed that the wood was dry in most places (0 – 16 % moisture; readings less than 18% are considered dry). On the southeast side of the south wall, Mold Remediation From Colorado Flooding there were some areas that had 18 - 20 % moisture. 

It was mentioned that there had been a torrential downpour the previous day, and Mold Remediation From Colorado Flooding due to window flashing being temporarily removed from the exterior of the building, it was theorized that this deluge caused water to seep into the wood- thus causing the slightly elevated moisture readings. 

It was also noted by the owner's environmental representative that wood moisture readings she took the previous day (before the rainstorm) had all been in the "dry" range. A small amount of water had also dripped inside at the large construction window (east side of building) and Mold Remediation From Colorado Flooding pooled on the sill. Six airborne mold samples from the first floor work area and one from outdoors were collected during this visit. 

All analytical results show a much smaller amount of mold spores inside the building than outside. This is the desired outcome, as it is evidence of no indoor fungal amplification. Sample number 253-25, which was collected in the suite at the "dogleg” (no suite number noted- see map page) had the most amount of spores found from the interior samples, Mold Remediation From Colorado Flooding and was approximately 1/3 the amount of the outdoor samples. 

It was observed that the large construction window was open in this area, Mold Remediation From Colorado Flooding so it is likely that most spores found were from the outdoors. WEC recommends that Alborn Construction replace the exterior window flashing as soon as possible to prevent any more water infiltration. 

After this has occurred, it is recommended to have the owner’s environmental consultant re-test the wood moisture content on the south and southeast walls to ensure it is dry (less than 18 % moisture). Once it is dry, Mold Remediation From Colorado Flooding then Alborn Construction may proceed with encapsulation, as well as replacing the vapor barrier, insulation, and sheetrock on all exterior walls scheduled for Phase 3.

How To Reason With Animal Hoarders

Hoarding is the acquisition of, and failure to discard a large number of possessions in a residence which appear to be useless or of limited value. Living spaces, furniture, appliances and utilities are sufficiently cluttered as to prevent their intended use, which could pose a significant risk to h  read more..

Recycle

What happens to the things you throw away? If you dispose of them in the trash, your old stuff will probably end up sitting in a landfill. But if you Debris Removal Recycle, the materials you got rid of yesterday could end up back on a store's shelf in the future. Recycle is the practice of reusing materials in exist  read more..

Lead Can Hurt Your Child

Lead can hurt your child. Take these steps to keep your child safe from lead. Keep your home clean and dust free. Wet mop floors, wet wipe window sills, vacuum, and wash all surfaces often. Use household cleaner and rinse with clean water. This keeps lead in dust from spreading in the house. Do not   read more..

How To Kill Mold In A Crawl Space

A properly sealed, moisture-protected, and insulated crawlspace will increase comfort, save on energy costs, improve the durability of the home, and reduce entry of moisture, radon, and other potential irritants or pollutants into the home. Crawl Space Drying How To Kill Mold In A Crawl Space Whichever design is followed, the keys to an  read more..

How To Clean Smoke Damaged Houses

In a secondary test procedure, the smoke-contaminated electronic counters were subjected to high humidity while powered. The less contaminated of the two exhibited no loss of functionality, while the other failed after an unknown amount of time in a 95 % humidity environment. It was determined that   read more..

Sewage Water Removal

Always call the county prior to calling a plumber when you experience a sanitary sewer backup and you feel that the problem is in the county sewer main line. If the backup occurs only when facilities (such as toilet, tub, washer or sinks) are used, it is possible that you need a plumber. If you have  read more..

Water Damage

Standing water is a breeding ground for a wide range of micro-organisms and insects, such as mosquitoes. Mosquitoes can spread diseases like West Nile Virus. Micro-organisms, including bacteria and mold, can become airborne and be inhaled. Where floodwater is highly infected, infectious diseas  read more..

Compulsive Hoarding

In the case of a compulsive hoarder, fire damage has occurred from time to time. Because of the condition of the house, where the Smoke Damage Compulsive Hoarding takes place, where empty packaging that should have been discarded will pile up next to their stove creating a unsafe fire h  read more..

Mold Remediation Protocol

If the remediation job disturbs mold and mold spores become airborne, then the risk of respiratory exposure goes up. Actions that are likely to stir up mold include: breakup of moldy porous materials such as wallboard; invasive procedures used to examine or remediate mold growth in a wall cavity; ac  read more..

Fire Damage Electronic Restoration Classes

Some Micro-miniature and Nano-miniature type connectors have the option of pre-terminated cross linked ETFE (TefzelTM) insulated wire pigtails. Users are advised that some ETFE insulations are known to out-gas trace amounts of corrosive fluorine over time. When this wire is used with nickel coated m  read more..