Dehumidification >> When Is Dehumidification Required?

The main cooling coil without being re-evaporated by radiant or conducted heat. The main cooling coil must be When Is Dehumidification Required? selected at a coil face velocity at least 150 fpm below the maximum cataloged face velocity to ensure that moisture does not carry over onto a reheat coil (liquid water carryover onto an active reheat coil results in additional energy consumption and humidification).

AHU fans and motors (if the motor is in the air stream) should be located downstream from the recuperative reheat system for optimum effectiveness. If a supplementary reheat coil is When Is Dehumidification Required? used and its leaving-air temperature is above 100 F, then the fan motor must be selected for reliable operation at the actual temperature conditions at the motor. 

It may be necessary to derate the motor and use Class F or H high temperature motor-winding insulation. Special motors are not required for recuperative-reheat systems not equipped with supplementary reheat coils. 

Because of the possibility of moisture condensing on precooling heat-transfer surfaces during part-load operating conditions, provisions for When Is Dehumidification Required? collecting and draining condensate must be made. Heat-exchange surfaces will accumulate particulate even with well maintained filters. Surfaces should be accessible and cleanable without difficulty or high cost.

The fifth recuperative-dehumidification enhancement is superior to the other four in many respects because it achieves almost the same result with a single coil located downstream from the main cooling coil. The single coil reduces first cost, When Is Dehumidification Required? halves the air-side friction of the recuperative elements, and requires no space or modifications upstream from the main cooling coil. 

With the fifth enhancement, which is applicable only to systems using refrigerant coils served by compressors, the amount of reheat is limited. If a significant temperature rise is required, When Is Dehumidification Required? this enhancement may need to be combined with one of the other four. Details on each of the five recuperative-dehumidification enhancements follow. 

Run-around coils for enhanced dehumidification systems are not a new technology. They are well-described in texts from as long ago as 1939.
The psychrometric-chart analysis of run-around coils for precooling and reheating is identical to that for ordinary reheat (see sidebar) with one exception: 

The precooling coil cools the entering air from 84- to 72-F dry bulb (DB); therefore, the air entering the main cooling coil is cooler,When Is Dehumidification Required? which means that the main cooling coil does not have to remove as much heat. The reheat is provided not by an external source of expensive energy, but by the heat picked up by the circulating fluid in the precoil. 

The cycle and savings are illustrated in Figure 2. Figure 3 is a piping diagram showing that run-around coils require a small closed-loop piping system. When freezing is a possibility, the heat-transfer fluid is dilute ethylene glycol; at other times, it is water. The system requires a means of fluid makeup. A diaphragm compression tank normally is installed for fluid expansion. 

If water (not glycol) is used as the circulating fluid and chilled-water or heating-hotwater lines are in the vicinity, When Is Dehumidification Required? it is possible to achieve fill and fluid expansion with a 3 ⁄8-in. connection to the chilled-water or heating-hot-water closed loop. The expansion of the fluid in the small run-around system then would be provided by the fluid-expansion equipment in the larger system.

 With only a single connection between them, there can be no flow between the two systems except for that induced by density forces of water at different temperatures. The system requires a fractional-hp pump, electrical service, When Is Dehumidification Required? and controls. The recommended pump for the circuit is a 120/60/1 hermetically sealed pump that does not require a shaft seal. 

If a pump with a seal is used, the seal should be mechanical rather than packed to minimize or eliminate leakage. The closed-loop piping system is close-coupled and confined to the immediate vicinity of the two coils. 

Once the circulating fluid is charged into the system, there is little possibility of leakage; therefore, When Is Dehumidification Required? the fluid-makeup system can be a hose connection or a funnel fill valve. Coils and piping must include manual air vents at high points to vent air at the time of initial filling. The piping connections to each coil must be arranged for "counterflow.” 

The lines between the two coils (and the coil headers if exposed to ambient air) must be insulated to prevent external heat transfer. The pump should be located in the warm-fluid line. All of the air passing through the air-handling unit must pass through both coils. Any deviations from these guiding principles will cause a loss in performance.

Advantages of runaround coils are:  They can be widely separated and arranged in any position. If desired, When Is Dehumidification Required? a single precooling coil can be used in combination with multiple reheat coils. They carry the certification of the Air-Conditioning and Refrigeration Institute (ARI) and are available from at least 10 manufacturers. 

Because they are mass-produced using machinery, labor contributes little to their cost. They are, for all practical purposes, commodity items and,When Is Dehumidification Required? therefore, relatively inexpensive. Their selection can be made by the manufacturer or by the manufacturer’s coil-selection program using software on a personal computer. 

The precooling and reheat function can be controlled by pump on-off cycling or valve control. The preheat coil can be piped to a third coil in the exhaust-air stream to capture heat for preheating outside air during the winter.

Disadvantages. Disadvantages of run-around-coil systems are: Possible freezing if water is the When Is Dehumidification Required? circulating fluid (this can be overcome by using a dilute ethylene glycol solution selected to provide burst protection at the coldest anticipated entering-air temperature).
 
A 120-v, 60-cycle single-phase electrical circuit is required for the circulating pump. Air trapped in the coils, When Is Dehumidification Required? pump, and piping must be vented upon initial startup to ensure effective fluid flow and heat transfer. Figure 4 shows run-around coils at the entering and leaving sides of a specially configured unit.

Hoarders

If and when first responders identify hoarding cases, they are trained to gather information and contact the Mental Health Clinician and Health Department while on site. Emergency situations often give rise to an environment conducive to a hoarders granting access to Health Department staff, so ever  read more..

How To Get Rid Of Dead Animal Odor

Sulfide is a colorless, flammable, extremely hazardous gas with a "rotten egg" smell. Some common names for the gas include sewer gas, stink damp,swamp gas and manure gas. It occurs naturally in crude petroleum, natural gas,and hot springs. In addition, hydrogen sulfide is produced by bacterial brea  read more..

Tropical Hurricane Hugo Storm Damage

Hurricane Hugo in 1989 was the most powerful Wind Damage Tropical Hurricane Hugo Storm Damage and rainstorm to hit the United States since 1969 when Camille hit the Gulf Coast. Hugo was disastrous and caused extensive residential wind damage, widespread lifeline annihilation, and massive timber devastation in South Carolina. The rainst  read more..

Get Rid Of Mold And Mildew In The Crawl Space Under A Mobile Home

Most building codes require crawlspace vents to aid in removing moisture from the crawlspace. However, many building professionals are now recognizing that an unvented crawlspace (or closing crawlspace vents after the crawlspace has had time to dry out after construction) is the best option in homes  read more..

Lead Paint Exposure Registry In California

Legislation in 1986 created a statewide system for tracking lead poisoning cases in children and adults in California (California Health and Safety Code Section 124130). Laboratories are required to report electronically all blood lead levels (BLLs) for persons tested Lead Paint Removal Lead Paint Exposure Registry In California in California to  read more..

Water Damage Mitigation After Flood

Expertise in environmental inorganic and organic chemistry and bio geochemistry. Increase understanding of aquatic-ecosystem health by enhancing technical associations with regulatory agency program managers, government-agency researchers, Water Extraction Water Damage Mitigation After Flood and other research groups. 

  read more..

Fire Damage Restoration For Electronics

Figure 11 shows a portion of the metal lead frame strip to which the individual capacitor elements will be attached in the early stages of the capacitor assembly process. The precise dimensions of the lead frame vary from manufacturer to manufacturer, but the function is the same. The leadframe prov  read more..

How To Clean Smoke And Soot Damage After A Fire

Acting United States Fire Administrator Charlie Dickinson and Fire Damage How To Clean Smoke And Soot Damage After A Fire National Fire Protection Association (NFPA) President and Chief Executive Officer James Shannon announced today the completion of a report on Behavioral Mitigation of Smoking Fires.(PDF, 5 MB)

The report is the res  read more..

Legal Consequences For Meth Labs

For chemicals which are absorbed through the skin and which are hazardous, the levels of exposure on the skin must be maintained below a level at which no adverse effects would be observed. Meth Lab Cleanup Legal Consequences For Meth Labs One of the simplest ways of determining this amount is to estimate the amount of a chemical which ca  read more..

How To Remove Mold On Drywall

I heard about "toxic molds" that grow in homes and other buildings. Should I be concerned about a serious health risk to me and my family?The term "toxic mold" is not accurate. While certain molds are toxigenic, meaning they can produce toxins (specifically mycotoxins), Mold Remediation How To Remove Mold On Drywall the molds them  read more..