Flood Damage >> Electrical Systems In Flood-damaged Buildings

Question: Do electrical systems and equipment submerged through flooding have to be replaced? Answer: Floodwaters are not just water; the water may also be contaminated with chemicals, sewage, oil and other debris. When the floodwater is salt water, its corrosive effects are particularly damaging. Any or all of those can affect the integrity and performance of electrical systems and equipment, Electrical Systems In Flood-damaged Buildings either immediately or eventually.  

Some of the larger types of electrical equipment, such as panelboards, switchboards, certain types of busways, some types of motor control equipment, circuit breakers, protective relays, meters and Electrical Systems In Flood-damaged Buildings current transformers exposed to floodwaters may be reconditioned. To recondition any electrical equipment requires that the work be done by qualified personnel and that the original manufacturer be contacted for specific recommendations. 

In many cases, it is ultimately safer, less expensive and less time-consuming to replace the equipment. Electrical equipment such as outlet and Electrical Systems In Flood-damaged Buildings junction boxes, arc fault circuit interrupters (AFCI), ground fault circuit interrupters (GFCI), surge protective devices, switches, receptacles, dimmers, and lighting fixtures exposed to floodwaters must be replaced.

Wiring or cable exposed to floodwaters may or may not be required to be replaced, depending on the type of wire or cable. Wire or cable listed for dry locations (such as NM-B) exposed to water must be replaced. Wire or cable that is listed for use in wet locations may remain - provided the ends of the wire or cable have not been exposed to water, Electrical Systems In Flood-damaged Buildings and the wire or cable is not damaged. 

But, even with wire or cable listed for use in wet locations, when the wire or cable has been exposed to the contaminants found in floodwaters, Electrical Systems In Flood-damaged Buildings the manufacturer should be consulted before any decision is made to continue using it. Again, in most cases, it is safer, less expensive and less time-consuming to replace the wiring or cable.

For more information, Electrical Systems In Flood-damaged Buildings the publication Evaluating Water-Damaged Electrical Equipment by the National Electrical Manufacturers Association (NEMA) contains practical guidelines and understandable explanations about the salvageability of electrical equipment, wiring, and cable.

Question: When evaluating submerged electrical systems and equipment, who is qualified to determine what is damaged and Electrical Systems In Flood-damaged Buildings must be removed, and what is not damaged and may remain? Answer The municipality determines who is qualified to evaluate submerged electrical systems and equipment for damage. 

Electrical contractors, licensed electricians (where required), third-party electrical inspectors, and utility company representatives would be considered qualified, having the training and Electrical Systems In Flood-damaged Buildings knowledge of electrical systems and equipment necessary to evaluate damage caused by contact with floodwaters. The code enforcement official may also recognize other individuals as being qualified, based on other criteria.

Question: It’s been determined that portions of the electrical system and/or equipment in a dwelling are damaged and have to be removed. What are the requirements for Code compliance? Answer: The requirements for Code compliance depend on whether the work necessary to restore the electrical system Electrical Systems In Flood-damaged Buildings and/or equipment to its pre-damaged state is a repair or a Level 1 alteration.Repairs. 

If the municipality determines that the restoration work is a repair, the installation of new system components and Electrical Systems In Flood-damaged Buildings equipment do not have to meet new construction standards. A repair is defined as the restoration to good or sound condition of any part of an existing building for the purpose of its maintenance. 

Examples of what could be considered repairs to an electrical system would be the replacement of receptacles, switches, and Electrical Systems In Flood-damaged Buildings light fixtures. Repairs do not normally require a building permit.Level 1 Alterations. If the municipality determines that the restoration work is a Level 1 alteration, the installation of new system components and equipment must comply with the requirements for new construction. 

Level 1 alterations are defined as the removal and replacement or the covering of existing materials, elements, equipment or fixtures using new materials, elements, equipment or fixtures that serve the same purpose, without reconfiguring the space. Examples of what could be considered Level 1 alterations to an electrical system would be the replacement of panelboards, circuit breakers, Electrical Systems In Flood-damaged Buildings and branch circuit wiring. Level 1 alterations require a building permit.

Question: The restoration work to the electrical system in the dwelling has been determined to be a repair. What are the Electrical Systems In Flood-damaged Buildings requirements for Code compliance? Answer: Appendix J Section J4 of the 2010 Residential Code of New York State (RCNYS) contains the provisions for repairs to one- and two-family dwellings and townhouses.

Section J401.3 requires that in a flood hazard area, if the repairs will be a substantial improvement, Electrical Systems In Flood-damaged Buildings the building must comply with the new construction provisions of Section R324. A substantial improvement is any repair or alteration to a building where the cost equals or exceeds 50 percent of the market value of the building before the repairs or alterations were started. 

Section R324.1.5 requires that electrical systems, equipment and Electrical Systems In Flood-damaged Buildings components replaced as part of a substantial improvement meet the requirements of the section, including being located at or above the design flood elevation plus a 2-foot freeboard as specified in Section R324.1.3.3. An exception allows electrical systems, equipment and components to be located below the design flood elevation provided specific conditions are met.

If the repairs will NOT be a "substantial improvement,” and in most cases, they are not, compliance with Section J407 is all that is required. Section J407 allows existing electrical wiring and equipment to be repaired or replaced with like materials, Electrical Systems In Flood-damaged Buildings with some exceptions.

Question: The restoration work to the electrical system in the dwelling has been determined to be a Level 1 alteration. What are the requirements for Code compliance? Answer: Appendix J Section J5 of the 2010 Residential Code of New York State (RCNYS) contains the provisions for Level 1 alterations to one- and two-family dwellings and Electrical Systems In Flood-damaged Buildings townhouses.

Section J501.3 requires that in a flood hazard area, if the alterations will be a substantial improvement, the building must comply with the new construction provisions of Section R324. Section R324.1.5 requires that electrical systems, equipment and Electrical Systems In Flood-damaged Buildings components replaced as part of a substantial improvement meet the requirements of the section, including being located at or above the design flood elevation plus a 2-foot freeboard as specified in Section R324.1.3.3. 

An exception allows electrical systems, equipment and Electrical Systems In Flood-damaged Buildings components to be located below the design flood elevation provided specific conditions are met. If the alterations will NOT be a substantial improvement, compliance with Section J508 is required. Section J508 requires that any alteration made to the electrical system meet the requirements for new construction found in Chapters E33 through E42.

Question: It’s been determined that portions of the electrical system and/or equipment in a building (which isn’t a one- or two-family dwelling or a townhouse) were damaged and have to be removed. What are the requirements for Code compliance for that building? Answer: Repairs or Electrical Systems In Flood-damaged Buildings alterations to buildings that are not one- or two-family dwellings or townhouses must be made in compliance with the 2010 Existing Building Code of New York State (EBCNYS). 

The municipality will still determine whether the buildings are undergoing repairs or Level 1 alterations. Alterations or Electrical Systems In Flood-damaged Buildings repairs may comply with Section 302.6 of Chapter 3 Prescriptive Compliance Method of the EBCNYS. Alternatively, Chapter 5 of the EBCNYS contains the provisions for repairs, and Chapter 6 contains the provisions for Level 1 alterations. 

The requirements in Chapters 3, 5 and 6 are similar to those in Appendix J – repairs or Electrical Systems In Flood-damaged Buildings alterations to buildings in a flood hazard area that are substantial improvements require compliance with Section 1612 Flood Loads of the 2010 Building Code of New York State.

Summary Electrical systems and equipment exposed to the contaminants in floodwaters must be carefully evaluated by qualified personnel. While some electrical equipment and Electrical Systems In Flood-damaged Buildings system components may be reconditioned or salvaged, in most cases, it is safer, less expensive and less time-consuming to replace them. 

The municipality will determine if the work necessary to restore the electrical system components and/or Electrical Systems In Flood-damaged Buildings equipment in a structure to its pre-damaged state will be a repair or a Level 1 alteration. The requirements for Code compliance are based on that determination.

Flood Prevention Ideas

The walls, floors, closets, shelves,

contents—every flooded part of

your house—should be thoroughly

washed and disinfected. Some projects, such as washing clothes, may

have to wait until all the utiliti  read more..

How To Remove Fire Damage From Furniture

Nineteen fire chiefs from around the world will participate in the National Fire Protection Association (NFPA) Urban Fire Forum in Boston, October 19-22. Also in attendance will be R. David Paulison. Fire Damage How To Remove Fire Damage From Furniture

Paulison is currently the Under Secretary of Federal Emergency Management/Direct  read more..

How To Start A Business Cleaning Trash Out Of For

Using a charge or threat of criminal trespass against tenants in order to evict them without the benefit of a court hearing is an abuse of the law. Police who participate in such an action may be guilty of official misconduct.108 In such cases, Tenant Move Out Cleanup How To Start A Business Cleaning Trash Out Of For tenants may sue both the landlord and th  read more..

How To Hide An Aluminum Sliding Window With Wood

Drain deaerator and open inspection doors and trays. Drain all boiler feed pumps and lines.7. Drain condensate receiver tank. Open manhole on tank.8. Drain chemical feed pump barrels and dispose of chemicals in a safe manner.9. Drain water softener tank and brine receiver.10. Shut off valves to main  read more..

Lead Paint Removal Health Risks

The zinc protoporphyrin test, unlike the blood lead determination, measures an adverse metabolic effect of lead and as such is a better indicator of lead toxicity than the level of blood lead itself. The level of ZPP reflects lead absorption over the preceding 3 to 4 months, and therefore is a bette  read more..

What Are The Mold Health Concerns?

What is Mold? Mold is a type of fungus that is present in our natural environment. Mold spores, which are tiny microscopic 'seeds', can be found virtually everywhere, including in homes, and are a part of the general dust found in homes. These spores can grow on building materials Mold Remediation What Are The Mold Health Concerns? and  read more..

Lead Based Paint Removal Requirements

How did the Lead Accreditation & Certification Program begin? California's lead accreditation and certification program began in June, 1994. At that time, new childhood lead poisoning prevention legislation (codified in Health and Safety Code 105250 et seq.) required the California Department of  read more..

How To Choose A Professional Dehumidifier

Flat-plate heat exchangers consist of a series of flat Dehumidification How To Choose A Professional Dehumidifier or nearly flat heat exchange surfaces arranged in such a way that alternating air passages are connected to one air stream with remaining passages connected to the second air stream. the recuperative application of the air-to-air   read more..

Remove The Smell Of Fire Damage From Wood Furnitur

TheFire Protection Research Foundation, an affiliate of theNational Fire Protection Association (NFPA), Fire Damage Remove The Smell Of Fire Damage From Wood Furnitur  resented the William M. Carey Award to the authors of a paper titled "Results of a Clinical Study of the Waking Effectiveness of Fire Signaling Devices.” 

  read more..

Freeze Dry Documents For Water Restoration

About 25 Alabama counties are already preparing loose marriage licenses, divorces, estate case files, and Confederate pension records for microfilming by the GSU. Another 15 counties have expressed interest in starting a loose records project. If your county government, historical society or genealo  read more..