Asbestos Abatement >> Asbestos Abatement Supplies

Joint compound used on wallboard systems often contains asbestos added during the mixing process to improve the working texture of the material. The asbestos in the joint compound is typically much less than 5 percent by weight and the joint compound makes up a minor fraction of the material in the wallboard system. Where Asbestos Abatement Supplies work with the wallboard system does not involve sanding, grinding or abrading the wall surface, joint compound will generally remain intact on the surface of the wallboard. The presence of joint compound has not been found to represent a greater hazard of asbestos exposure than treating the wallboard system as a homogenous material. It is important to implement prompt clean-up procedures and avoid pulverizing debris generated during the work.

Because of the circumstances presented by the use of asbestos in such joint compounds, questions arise relating to the application of the requirements of the asbestos standards adopted by the Department of Labor and Industries (L&I) under the authority of the Washington Industrial Safety and Health Act (WISHA), RCW 49.17 and the Washington Asbestos Act, RCW 49.26. II. Scope and Application This WISHA Regional Directive (WRD) provides guidance to WISHA enforcement and consultation staff whenever they must address Asbestos Abatement Supplies issues concerning employee exposure to hazards involving asbestos-containing joint compound in wallboard systems.

This document does not address materials sprayed or applied with a trowel across the full surface of the wall (such surfacing materials are covered under the Class I work provisions of the asbestos standard, found in WAC 296-62-07712). This WRD supersedes all previous guidance on this subject, both formal and informal. Sampling for joint compound. Owners and employers can generally rely upon full-depth Asbestos Abatement Supplies samples of wallboard systems containing joint compound collected during building inspections. For general demolition and other work dealing with the wallboard system as a whole, building surveys using samples representing the full depth of wallboard material meet the good faith survey requirements.

Where sample results identify trace or less than one percent asbestos for the wallboard system, some basic requirements of the asbestos standard will apply but the work will not be considered an "asbestos abatement project" under the definitions of the standard. However, full-depth samples are not sufficient for wallboard systems where surfacing materials are present or where work will specifically disturb joint compound. Building inspectors must examine wall systems in sufficient detail to identify extensive patching or Asbestos Abatement Supplies application of surfacing layers on walls (as per the EPA AHERA inspection protocols for identification of surfacing materials in 40 CFR 763 Part E). These applications are considered to be "surfacing materials" under the standard, although similar plaster products may be used for joint compound.

Surfacing materials have been associated with extensive asbestos exposure and have more stringent handling requirements than most other materials (see the OSHA preamble to the 1994 rulemaking for additional discussion). Where work practices will selectively disturb joint compound, a full depth sample may not represent the Asbestos Abatement Supplies workplace hazard. For example, sanding or scraping a wall may specifically disturb the joint compound and create dust and debris composed primarily of joint compound. Building inspectors must assess the work to be conducted and sample the materials representative of the hazard presented by the work. This may be accomplished using individual samples of different layers or having layers within samples analyzed separately.

WISHA enforcement staff may elect to collect samples of dust or debris from the workplace or sample specific materials to make an assessment of the hazard represented by these materials. The specific work activity associated with the sample must be documented. A full-depth Asbestos Abatement Supplies sample result may substitute for layered results in situations where full-depth sampling is determined appropriate by an accredited building inspector. However, where sampling of joint compound has detected asbestos, the overall wallboard materials must not be reported as asbestos free. Previous sampling may have been conducted for significantly different projects and specifically focused on joint compound (for example, samples assessing a prior painting project where sanding of the wall surface was planned).

It is also common practice for laboratories to report layer by layer results for quality control reasons, whether or not this analysis is requested. In either case, it is improper to ignore the known presence of asbestos, but additional information may be collected and used to characterize the overall hazard due to asbestos in the current work. An accredited building inspector must conduct any reassessment of wallboard systems. The Asbestos Abatement Supplies reassessment must be conducted based on objective information collected during inspection of the wallboard system by an inspector or laboratory analysis of samples collected in accordance with EPA protocols. Pertinent objective information includes field documentation of the layers present in the samples and the relative quantities of materials represented by the samples.

The level of proof should be equivalent to that for rebuttal of PACM designation and EPA inspection and analysis protocols must be followed. If resampling is conducted with full depth analysis and no asbestos is detected, the wallboard system must still be reported as containing trace or less than one percent asbestos based on the initial sampling.

How To Remove Asbestos Paint From A Ceiling

Treat at least two different areas of each phase in this fashion. Choose representative areas of the sample. It may be useful to select particular areas or fibers for analysis. This is useful to identify asbestos in severely in homogeneous Asbestos Abatement How To Remove Asbestos Paint From A Ceiling samples. 

  read more..

Will Using Dehumidifier Get Rid Of Mold In A Room

In addition to correctly installing a vapor barrier, it is important to provide adequate ventilation of spaces where moisture can build up. Most building codes require that attics and crawl spaces be ventilated, Dehumidification Will Using Dehumidifier Get Rid Of Mold In A Room and some require a minimum one-inch clear airspace above the insulation for ve  read more..

Fire Damage

Any case of fire damage that the fire department or the use of fire sprinklers have been involved will require a certain amount of Dehumidification Fire Damage. When a typical fire breaks out and the fire department arrives, in almost every case water will be employed to put out the fire. The utilization of the water  read more..

Restore Old Photos That Have Had Moisture Damage

Categories of membership may provide some indication of the conservator's experience. In particular, "Fellow" or "Professional Associate" membership in AIC is conferred after a specified number of years in the field, Document restoration Restore Old Photos That Have Had Moisture Damage based on a peer- review process.

These membership categories i  read more..

How To Keep Moisture Out Of Your Basement

TIPS FOR DRYING OUT A WATER-DAMAGED BUILDING F. Mitchener Wilds, Senior Restoration Specialist
 Once a building has been exposed to a large volume of water, either floodwater or rainwater, steps must be taken to dry the building out, assess damage, and Basement Drying How To Keep Moisture Out Of Your Basement plan for repairs a  read more..

Signs Of Animal Damage And Useful Animal Informati

Can deer with EHD (Epizootic Hemorrhagic Disease) be harmful to humans? The most important thing for hunters, landowners, and the public to know is that this is a regular and natural event that routinely afflicts white-tailed deer and that it is not transmissible to humans or Animal Damage Signs Of Animal Damage And Useful Animal Informati any othe  read more..

Roofing Removal Tips

Assess weight-based rather than volume based payment for debris collection and investigate whether such systems could be efficiently linked to debris payment accounting systems. Management Comments and OIG Analysis FEMA generally concurs with all of these recommendations, but notes that the Age  read more..

How To Start A Business Cleaning Trash Out Of For

Using a charge or threat of criminal trespass against tenants in order to evict them without the benefit of a court hearing is an abuse of the law. Police who participate in such an action may be guilty of official misconduct.108 In such cases, Tenant Move Out Cleanup How To Start A Business Cleaning Trash Out Of For tenants may sue both the landlord and th  read more..

How To Promote Emergency Preparedness

Bomb Threat If you receive a bomb threat telephone call:Remain calm.Listen carefully. Be polite and show interest.Try to keep the caller talking to learn more information. If possible, Emergency Board up How To Promote Emergency Preparedness write a note to a colleague to call the authorities or, as soon as the caller hangs up, immediately   read more..

Hurricane Flooding Facts

Do I need the Hepatitis A vaccine?There is no indication for the Hepatitis A vaccine given the anticipated conditions in the region Water Damage Hurricane Flooding Facts and low probability of exposure. No transmission from contaminated water has been identified in the U.S. since the 1980's. 

<  read more..