Wind Damage >> Emergency Board Up

Plywood shutters that you create yourself, if placed correctly, could provide a high degree of Emergency Board Up coverage from flying debris during a storm. Plywood shutters could be placed on all kinds of houses. Measure every window and every door that has glass, and add 8 inches to all the height and width to provide a 4-inch overhang on every side of the window or door. Pieces of plywood are generally 48 inches by 96 inches (4 x 8 feet).

  1. Inform your local hardware supply store the dimensions and amount of openings you require to cover the Emergency Board Up to decide how many pieces of plywood to buy. To place plywood shutters, you may require bolts, wood or brick anchors, big washers, and 5/8-inch exterior-grade plywood. For windows 36 × 48 inches or littler placed on a wood framed house, utilize 1/4-inch lag bolts and plastic-coated durable anchors. The lag bolts shall intrude the wall and framed area the window at minimum 1-3/4 inches. For bigger windows, utilize 3/8-inch lag bolts that intrude the wall and framed area the window at minimum 2-1/2 inches. For windows 36 × 48 inches or littler placed on a brick house, utilize 1/4-inch expansion bolts and galvanized durable 2 inch expanding anchors.
  2. The expansion bolt shall intrude the wall at minimum 1-1/2 inches. For bigger windows, utilize 3/8-inch expansion bolts that intrude the wall at minimum 1-1/2 inches. The items you may require are a circular or hand saw, a bore with the accurately dimensioned bits, a mallet, and a spanner to fit the bolts. To be secure, utilize eye coverage and work gloves. Saw the plywood to the measurements for every opening. Bore holes 2-1/2 inches from the outside edge of the plywood at every corner and at 12-inch intervals. Bore four holes in the center area of the plywood to relieve pressure during a strong Emergency Board Up storm.
  3. Place the Emergency Board Up plywood over the opening, and mark every hole position on the outside wall. Bore holes with the appropriate dimensions and type of bit for the anchors. Place the anchors, the plywood, and the bolts to create sure they fit correctly. On wood-framed houses, create sure that the anchors are secured into the solid wood that framed the door or window and not into the siding or trim. Mark every shutter so you may know where it is to be placed, and store the shutters and the bolts in an accessible place.
  4. If the opening is bigger than one sheet of plywood, you may require you to create shutters with 24 × 48 bracing. This bracing could be two 24 × 48s at the middle and bottom of the two pieces of plywood, evenly spaced, with the 2-inch side attached to the inside of the Emergency Board Up storm shutter. Attach the 24 × 48s to the outside of the Emergency Board Up storm shutter with 2-inch, 10-gauge wood screws before placing the shutter. Impact-resistant windows are optimal for windows not easily fitted with hurricane shutters or those that are hard to reach.

Water Extraction From Carpet After Pipe Breaks

In addition to the decline in land-surface altitude,the loss of marshes and barrier islands that dampen storm surge and waves during hurricanes increases the risks of flood disaster in New Orleans Water Extraction Water Extraction From Carpet After Pipe Breaks and vicinity.

Since 1940, approximately 1 million acres of c  read more..

How Does A Radon Test Work

The meanings of these terms apply specifically to the RPP. The specialized definitions noted here are used in place of those found in standard dictionaries.Accepted application: An Application that has been entered into the Program database. Acceptance date: The Radon Mitigation How Does A Radon Test Work date on which EPA comp  read more..

Mold Cause Problems With Allergies

Though disseminated coccidioidomycosis is uncommon, and symptomatic coccidioidal pneumonia usually resolves without therapy, many of these patients are very ill for weeks to months. Galgiani reported that a group of college students in Tucson who had coccidioidomycosis required an average of six cli  read more..

Safely Remove Black Mold

 
The more serious health problems have been associated with the toxic black mold, Stachybotrys atra. The mold is greenish-black and slimy, resembling tar or black paint.  read more..

How To Remove Residential Lead Paint

Lead test kits are products sold to consumers for use in detecting the presence of lead.Historically, test kits have been developed to detect lead-based paint as defined by the "Lead Safe Housing Rule," (24 C.F.R. Part 35). Under this rule, administered by the Department of Housing and Urban Develop  read more..

How To Get Rid Of Sewage

Overhead Sewers. The basement floor drain and any plumbing fixtures in the lower levels of your house that have experienced backups will be disconnected from the sewer system. Plumbing from those fixtures will be re-routed to a sealed tank. Inside the tank,an ejector pump lifts the waste water up se  read more..

Grants For Ice Storm Tree Removal

Determine Management Options and Goals
Any disaster debris management plan should include a disposal strategy. Communities need to set priorities for recycling wastes and determine the desired disposal options for the remaining waste. Segregate Hazardous Waste - Be prepared to [M  read more..

Crime Scene Robbery Cleaner Training

OSHA is concerned that the words "treated to render bloodborne pathogens noninfectious" may present a problem because there is little or no information in the record that deals with such treatment. The standard does recognize that some blood and blood components and blood products present littl  read more..

Call A Lead Paint Removal Specialist

Paint or varnish peeling, chipping or flaking? Mop floors to clean instead of sweeping. Carpets are good to cover painted wood floors. Wet scrape or wet sand to avoid creating dust: repaint surface with two coats of paint; encapsulant paint is the best. Painted Furniture & toys have paint chi  read more..

Requirements For Workers Exposed To Lead

Requirements for Workers Exposed to Inorganic Lead Under the standard for inorganic lead in the construction industry, initial medical surveillance consisting of biological monitoring to include blood lead and ZPP level determination shall be provided to employees exposed to lead at or Lead Paint Removal Requirements For Workers Exposed To Lead abo  read more..