Electronic Restoration >> Silicone Outgasses

Silicone outgasses and is a concern even in a cable configuration where the outer jacket can protect the system from small amounts of enclosed outgassing material. Current product typically contains relatively large quantities of silicone. The Gore-Tex® construction has not yet been Silicone Outgasses evaluated. 

The task of stripping polyamide coated fiber is not trivial. Polyamide coating can be stripped only with hot sulfuric acid for space flight applications; hot sulfuric acid can be dangerous and is not portable. Mechanical stripping methods are not recommended for flight cable assemblies because they can introduce surface flaws to the glass fiber, Silicone Outgasses compromising long-term reliability.

Connector manufacturers have tried to circumvent this problem by offering a ferrule hole size that will accommodate the unstripped polyamide coating's outer diameter. This approach has not been accepted readily by the industry because it makes the connectors considerably more expensive Silicone Outgasses and forces the user to commit to a non-standard configuration. 

When used in single mode applications, where perfect alignments are crucial to limiting the insertion losses, Silicone Outgasses the polyamide coating still must be removed before terminating the fiber due to the tighter tolerance constraints of single mode connectors. Hermetic polyamides over amorphous carbon coatings are susceptible to failure. 

The failure mode for one loose tube cable configuration was Silicone Outgasses determined to be caused by method of extrusion. The full analysis is contained in reference 7, the "ISS Fiber Optic Failure Investigation Root Cause Report". There have been no reports of hermetic polyamide coated optical fiber failures in tight tube configurations. 

Currently, nonhermetic coatings are recommended over hermetic when feasible. CABLES The standard cable construction includes the coated fiber, which is supplied by a fiber manufacturer and has a unique part number, a tight or loose tube buffer, woven Silicone Outgasses or spiraled strength members, and an outer jacket. 

Each cable component performs an important function in the overall mechanical reliability of the terminated fiber. The coating, which is physically in contact with the fiber, greatly affects optical performance. Part number traceability is limited to the finished cable Silicone Outgasses and the coated fiber. The performance and manufacturability of cables are heavily dependent on the materials used. 

Most optical cable jackets considered for use in space flight are extruded Teflon or Tefzel. The materials currently in use for loose tube buffers are Teflon, Tefzel, Kynar (PVDF) or Hytrel, tight fiberglass or Kevlar (Aramid). Properties of these Silicone Outgasses materials are outlined in Table 1. A validation test should be conducted on connector ferrule hole dimensions and tolerances prior to procurement. 

This test ensures that the fiber will be reliably centered in the hole after termination. This test is particularly important when Silicone Outgasses inspecting nonstandard ferrule sizes. The ferrule sizes that are commonly used are 125 or 140 microns. An excessive amount of epoxy will be required if the ferrule hole is too large for the bare fiber outer diameter. 

The terminated fiber will not mate properly to another if a mismatch is created due to non-concentric Silicone Outgasses fiber placement within the ferrule. Terminated fiber end faces must be visually inspected at 200X to ensure that the position of the fiber is central to the hole of the ferrule. 

MATERIAL OUTGASSING Selection Silicone Outgasses and use of non-metallic materials in cables shall be traceable to test reports with acceptable levels of TML and CVCM as listed in NASA reference publication 1124 (outgassing data for selecting spacecraft materials) or NASA MSFC Handbook 527 (Materials Selection List for Space Hardware Systems).

However, materials listed as acceptable in these publications may have been baked out for evaluation, Silicone Outgasses and the user may have to repeat the same processing. This processing usually consists of a vacuum bakeout of 125 C and a vacuum of 10 -6 TORR for 24 hours. Acrylate optical fiber coating does not pass the ASTM 595E vacuum outgas test. 

However, it can be used in a non-outgassing cable configuration. Other materials that are prone to outgassing in a vacuum environment are the epoxies used for terminating assemblies, connector boot materials, cable configuration materials, Silicone Outgasses and all plastic connector parts. In the past Kevlar was considered to be a contamination concern for assemblies; it will absorb 3% of its weight in moisture.

Any absorbed water shall be driven off with a thermal preconditioning step prior to termination. At present Silicone Outgasses there are only a few epoxies qualified for space flight cable assemblies. Goddard Space Flight Center uses Tra-Con Bipax and Tra-Bond BA-F253 for fiber optic space flight cable assemblies using the Johanson FC connector. 

EPO-TEK 353ND is used for termination of the Diamond AVIMS. Two epoxies from AngstromBond were recently tested for their outgassing characteristics both inside Silicone Outgasses and outside of a cable configuration. The two test epoxies used in the experiment were the Angstrom Bond AB9119 and the Angstrom Bond 9112 fiber optic epoxies. 

The cable test showed inconclusive results.The ASTM 595E test conducted on the epoxies alone showed that the AngstromBond AB9119 passed while the AngstromBond 9112 did not [8]. TERMINATIONS The termination process must be well understood Silicone Outgasses and controlled in order to reduce the chance of inducing surface crack growth in the fiber. 

Crack growth can be induced during any step of the termination process. The proper epoxies and strain relief materials must be used to avoid radial or Silicone Outgasses lateral stress on the fiber. Crack growth can be a longterm failure mechanism that is difficult to simulate in the laboratory. All terminated cable assembly preparation work must be performed using space flight procedures including those found in NASA-STD-8739.5, 

Fiber Optic Terminations, Cable Assemblies, and Installation. Termination techniques that are appropriate for highly reliable assemblies in space flight environments are well understood Silicone Outgasses and practiced by the APIM laboratory. Code 562's past experience has been that it is very time consuming and difficult to ensure that commercial vendors fabricate assemblies in compliance with NASA-STD-8739.5.

Due to this experience, in-house fabrication is recommended. All cable must be thermally preconditioned prior to termination. During termination chemical stripping is used to remove optical fiber coatings. Performing a strippability validation test is recommended for flight fiber to ensure that space flight termination procedures can be accomplished. Other methods of stripping fiber are available, Silicone Outgasses but none at present have been approved at GSFC for space flight terminations.


Eliminate Mold And Mildew On Basement Walls

Permitting
 You or your moving contractor will have to obtain permits to move the house on public roads or other rights-of-way. These permits may be required by local governments, highway departments, and Basement Drying Eliminate Mold And Mildew On Basement Walls utility companies, not only in the jurisdiction from which your ho  read more..

Will Using Dehumidifier Get Rid Of Mold In A Room

In addition to correctly installing a vapor barrier, it is important to provide adequate ventilation of spaces where moisture can build up. Most building codes require that attics and crawl spaces be ventilated, Dehumidification Will Using Dehumidifier Get Rid Of Mold In A Room and some require a minimum one-inch clear airspace above the insulation for ve  read more..

Securing A Fenced Perimeter

Two keys to weather safety are to prepare for the risks and to act on those preparations when alerted by emergency officials. These are essential pieces to the Weather-Ready Nation.Refer to the Federal Emergency Management Agency's (FEMA) Ready.gov/hurricanes for comprehensive Emergency Board up Securing A Fenced Perimeter information on hu  read more..

Exposure To Lead

Lead is a naturally occurring element found in small amounts in the earth's crust. While it has some beneficial uses, it can be toxic to humans and animals causing of health effects.Where is Lead Found?Lead can be found in all parts of our environment – the air, the soil, the water, and Lead Paint Removal Exposure To Lead&n  read more..

How To Pump Water Out Of A Flooded Basement

Techniques for controlling the entry of termites through residential foundations are advisable in much of the United States (see Figure 2-8). The following recommendations apply where termites are a potential problem. Consult with local building officials and codes for further details. Basement Drying How To Pump Water Out Of A Flooded Basement Min  read more..

How Long Do Hurricanes Last

The most critical aspect of building in hurricane hazard areas is the method of connecting the structural members. Pilkey et al. (1981) note that wood is one of the best materials for absorbing short-duration loads such as those caused by wind, but the strength of wood cannot be used to advantage if  read more..

How To Remove Toxic Smoke Damage From An Apartment

Recommendations for the Selection and Use of Respirators and Protective Clothing for Protection against Biological Agents From the National Institute for Occupational Safety and Health The approach to any potentially hazardous environment, including one with biological hazards, must be made with a p  read more..

Best Way To Remove Tornado Damage Debris

Develop:1 performance measurement that FEMA headquarters and regional personnel call use to measure, analyze, and improve debris program performance. This should be designed for easy analysis of cost and performance data across regions, disasters, and Debris Removal Best Way To Remove Tornado Damage Debris contractors. FEMA a!,'TCCS with t  read more..

Delicate Fire Cleanup

An Account of the Conservation and Preservation Procedures Following A Fire at the Huntington Library and Art Gallery Barbara Roberts , Carol Verheyen , William S. Ginell, Stanley Derelian, Leonard Krowech, Teresa Longyear, Billie Milam, Barbara Roberts, Linda Strauss, Deborah Silguero, Ron Tank, Ja  read more..

Flood Maps

Why is participation in the NFIP on a community basis rather than on an individual basis? The National Flood Damage Flood Maps Insurance Act of 1968 allows FEMA to make flood maps insurance available only in those areas where the appropriate public body has adopted adequate flood maps management regulations for its fl  read more..