Structural Drying >> Ceilling Leak From Rain

GLOSSARY OF USEFUL TERMS Affected air the space within in a room or building which is influenced by or can influence the moisture content level of material inside that room or building. AHAM (Association of Home Appliance Manufacturers) an industry association which publishes test results for water removal performance Ceilling Leak From Rain of dehumidifiers manufactured in the United States. 

Performance is tested in an environment at 80*F and 60% RH for 24 hours.Bound water water absorbed and chemically held within a material; Ceilling Leak From Rain in wood it is water absorbed into the wall structure of cells. Category of Water the degree of which water is contaminated - category 1 water is from a sanitary source, category 2 water is from a source containing a significant degree of contamination.

Category 3 water is water from a grossly contaminated source; Ceilling Leak From Rain category 1 or 2 water can deteriorate if left in building material for a period of time. CFM (cubic feet per minute) a unit of measurement for the volume of airflow which is used to determine the amount of air exchanged during a period time. Condensation the process which water vapor forms into a liquid on surfaces when moist air is in contact with cooler surfaces. 

Conventional refrigerant dehumidifier a drying equipment unit which employs air movement over a cold surface that forces the condensation of water vapor; Ceilling Leak From Rain the dried air is then heated and circulated into the affected air to collect more moisture. Conventional refrigerant units can remove water vapor from air down to 55 GPP. 

Dehumidification the process which removes moisture from air. Desiccant dehumidifier Ceilling Leak From Rain  a drying equipment unit which employs air movement through a moisture absorbing medium which to pull moisture from air. Desiccant units can remove water vapor from air down to zero GPP. 

Dew point (DP) the temperature which air becomes saturated Ceilling Leak From Rain and water vapor condenses to a liquid.Dry Goal the target moisture level for affected materials which require drying.Dry Standard the moisture content level of unaffected materials or known dry materials in an affected building, which are used to establish a drying goal for affected material which require drying.

Drying chamber an area enclosed or created for the purpose of promoting effective drying. Equilibrium moisture content (EMC)  the condition of a material at which it is stabilized due to the existing moisture content of the affected air; Ceilling Leak From Rain the condition at which moisture in a material neither increases nor decreases. 

Evaporation  the process Ceilling Leak From Rain which changes liquid water to a gas (water vapor). Free water absorbed water located within the open spaces of pores of a material. Grains per pound (GPP) a unit of measurement of the amount of water vapor in one pound of air (humidity ratio). 

Institute of Inspection, Cleaning, and Restoration Certification (IICRC) - The IICRC is a certification and standard-setting non-profit organization for the inspection, cleaning and restoration industries, Ceilling Leak From Rain which publishes the "S500 - Standard and Reference Guide for Professional Water Damage Restoration" an ANSI approved procedural standard used by the water restorative industry.

Low grain refrigerant (LGR) dehumidifier a drying equipment unit which employs air movement over a cold surface and a pre-cooling device, which forces the condensation of water vapor to a greater degree of efficiency in drier air conditions, Ceilling Leak From Rain compared to a conventional or standard dehumidifier. 

LGR units can remove water vapor from air down to 34 GPP. Moisture content (MC) the percentage or weight of moisture in a material compared to the weight of that material when completely dry. Moisture map a floor plan sketched of the affected area with the locations of moisture readings of affected and unaffected building material, Ceilling Leak From Rain recorded at least daily over the course of a drying project.

Negative air pressure condition created by removing the air from the affected area which to create infiltration, Ceilling Leak From Rain the process which draws in outside air into the affected area.Permeability the rate of which moisture passes through a material. Porosity the degree of which a material is porous or contains pores, openings or holes. 

Preservative a compound applied to the surface of salvageable material to suppress the growth of fungus, mold, and or mildew, Ceilling Leak From Rain or to prevent the infestation of wood-boring insects. Psychrometric chart a graph diagram showing the relationship between temperature, relative humidity, grains per pound, dew point and vapor pressure. 

Relative Humidity (RH) the percent of moisture in the air by volume at a specific temperature. Secondary damage the unwanted and irreversible change to an unaffected area of a building or to unaffected material, from the effects of excessive moisture, dehumidification, air movement, Ceilling Leak From Rain or heat.

Standard of care the practice recognized by industry which is most common to reasonable and prudent members of that trade that demonstrates being qualified Ceilling Leak From Rain and competent. Standard refrigerant dehumidifier see conventional refrigerant dehumidifier Surface water moisture found on the outermost layer of a material. 

Vapor pressure the force exerted by a gas (water vapor) onto its surrounding environment. EXAMPLE CLAIM USING METHOD (2)x Single floor on concrete slab; affected area is 50 x 40 x Flood water in the building for 24 hours, interior water 24 inches x Professional drying started on the 5th day after building tear-out, cleaning Ceilling Leak From Rain and sanitizing against mold and mildew; there is no drying log x 

Insurance estimate will include the removal and replacement of perimeter and interior wall coverings are removed to 4 foot level; all wall studs and exterior sheathing are exposed x Assume drying scenario "C" DURATION Drying started within 5 days after tear-out, Ceilling Leak From Rain cleaning and sanitizing allow 2 days for drying bound water 

AIR MOVERS For two day duration, day 2 50% of the # of airmovers for Day 1 Day 1 2000 135 SF = 15 Day 2 8 Day 3 0 Total 23 (average 12.5 per day or 1 per 174/sf) DEHUMIDIFIER (LGR) - 2000 SF X 8 foot ceilings 50 factor = 320 pint per day (ppd) needed Ceilling Leak From Rain Standard size 70 X 3 = 210 ppd for 2 days Large size 130 X 1 = 130 ppd for 2 days Total 340 ppd 

EXAMPLE DEHUMIDIFIER SIZES AND CAPACITY RATING LGR STANDARD SIZE 70 PPD LARGE SIZE 130 PPD EXTRA-LARGE SIZE 170 PPD DESSICANT STANDARD SIZE 385 CUBIC FEET PER MINUTE (CFM) or (116 PPD) LARGE SIZE 900 CFM (344 PPD) STANDARD TRAILER MOUNTED 1800 CFM (1000 PPD) LARGE TRAILER MOUNTED 4800 CFM (3032 PPD)

Mold Is Growing On The Soil In A Crawl Space

MOLD AND MOISTURE PROBLEMS IN CRAWLSPACES Introduction Some houses in Idaho and across the country have problems with standing water or moisture in the crawlspace, providing a perfect environment for mold growth and Crawl Space Drying Mold Is Growing On The Soil In A Crawl Space other moisture problems. 

For  read more..

How To Test For Lead Paint

The measurement of your blood lead level(BLL) is the most useful indicator of the amount of lead being absorbed by your body. Blood lead levels are most often reported in units of milligrams (mg) or micrograms (µg) of lead (1 mg = 1,000 µg) per 100 grams (100 g), 100 milliliters (100 ml) or [M  read more..

How To Clean Up From A Sewer Backup

Sanitary sewer overflows can be caused by too much precipitation infiltrating leaky sewer pipes, inadequate system capacity to handle newly-developed residential or commercial areas, blocked or broken pipes, or improperly designed and installed sewer systems. Sewage backups not only present unpleasa  read more..

What Is Radon

What is what is radon? What is radon is a radioactive gas released from the normal decay of the elements uranium, thorium, and radium in rocks and soil. It is an invisible, odorless, tasteless gas that seeps up through the ground and diffuses into the air. In a few areas, depending on local geology,  read more..

Protecting Your Home

Wind can tear the roofs from buildings, rip siding from exterior walls, and throw debris through windows. Falling trees can crush roofs and walls. Of course, hurricanes and Wind Damage Protecting Your Home tornadoes generate exceptionally destructive winds that can turn buildings into piles of rubble. But high winds   read more..

Radon Health Risk Information

Radon is the second leading cause of lung cancer, after smoking. The U.S. Environmental Protection Agency (EPA)and the Surgeon General strongly recommend taking further action when the home's radon test results are 4.0 pCi/L or greater. The concentration of radon in the home is measured in Radon Mitigation Radon Health Risk Information   read more..

What Is Asbestos

Who is at risk for an what is asbestos-related disease? Everyone is exposed to what is asbestos at some time during their life. Low levels of what is asbestos are present in the air  read more..

FEMA Debris Disposal And Flood Maps

Management and Disposal of Flood Debris In response to the flood disaster, the Colorado Department of Public Health and Environment ("Department") is providing guidance and regulatory relief for the management and Debris Removal FEMA Debris Disposal And Flood Maps disposal of damaged or destroyed structures, vegetation debris, vehicle  read more..

Lead Abatement Methods

If blood lead level has substantially declined during the period of removal. From September 8, 1979 to September 8, 1980, the blood lead level requiring employee medical removal is 80 µg/100 g. Workers found to have a confirmed blood lead level at or above this value need only be removed fro  read more..

Tips On Cleaning A Hoarders House

Still, we don't look for history of child abuse in ants, discuss ant toilet training, or accuse ants of character flaws and laziness. And we don't imagine that ants are crazy or that their problems are all in their heads because, after all, these are ants. But if "mentally ill" isn't accurate, what   read more..