Structural Drying >> Ceiling Leak Under Bathroom

For constant boundary conditions, a homogeneous material, and a fully developed moisture profile, the signal velocity of this profile inside the material is constant over the square root of time. This is well known and frequently observed for water absorption, Ceiling Leak Under Bathroom but it applies similarly for the drying. The main difference is that the moisture profile does not develop as quickly. 

In fact it is the end of the first drying phase that is characterized by the completed development of a distinct moisture profile. Once this profile is there, Ceiling Leak Under Bathroom the end of the drying processshould only depend on the signal velocity and the height of thematerial sample. 

The duration of the second drying phasemust, therefore, increase quadratically with the sample height,provided that the drying was started at a moisture contentsufficiently high to allow a clear distinction between first andsecond drying phases.This was investigated by a simulation study on drying offour different materials: calcium silicate brick, ceramic brick, aerated autoclaved concrete, Ceiling Leak Under Bathroom and calcium silicate insulation.

The material properties were taken from Scheffler (2008). The drying was calculated one-dimensionally for different sampleheights with constant boundary conditions of 20°C (68°F) and50% RH. It was started at effective saturation. The results are presented in Figure 7. The left chart shows the total dryingduration versus sample height; Ceiling Leak Under Bathroom the right chart shows only thesecond drying phase duration versus sample height.

The results confirm the above reasoning. The duration of the second drying phase increases quadratically with the sample height. In other words, Ceiling Leak Under Bathroom the square root of the second drying phase duration plotted versus sample height gives a linear relation (see right-side chart of Figure 7).

We therefore propose the following relation (Equation 3) as the definition of the new drying coefficient for building Ceiling Leak Under Bathroom materials: (3)where= drying coefficient in = drying time of the second drying phase in = sample height in The second drying phase duration is the timebetween the deviation from the linear drying and the end of thedrying process (see also Figure 1). 

In other words, it is the timebetween the end of the first drying phase and the moment where the equilibrium moisture content is reached everywhere inside the sample. For measured data, Ceiling Leak Under Bathroom this depends on the frequency of measurement as well as the boundary temperature and relative humidity and might, therefore, be susceptibleto error. 

It is proposed to use calculation results of the dryingprocess normalized to standard conditions. From such data, Ceiling Leak Under Bathroom the second drying phase duration can be easily determined. For most materials, the first drying phase duration isnegligible in the overall drying time. This allows simplifyingthe found relationship to be true also for the total drying timeand not only for the second drying phase duration for which itis strictly correct. 

The left-side chart in Figure 7 shows thetotal drying time versus sample height. The linear relationshipholds for all materials except the calcium silicate insulation, Ceiling Leak Under Bathroom which has a very high porosity (90%) and a very long firstdrying phase. This new drying coefficient gives a measure for the timeit takes to one-dimensionally dry out one meter of material. 

Asdiscussed before, Ceiling Leak Under Bathroom for most building materials this is correct forthe total drying time even though it is strictly only valid for thesecond drying phase. Example values for drying coefficientsof typical building materials are given in Table 2.Discussion of the Proposed Drying CoefficientThe drying coefficient gives a measure of the timerequired to dry out 1 m of material. 

By that, it has a particularmeaning and is a practically useful material parameter. Thequestion is now, Ceiling Leak Under Bathroom however, whether this parameter contains additional information in comparison with the other two moisture transport parameters, i.e., vapor diffusion resistance andwater absorption coefficient. 

For that reason, these coefficients were related to each other for numerous building materials (drying coefficient of material A divided by dryingcoefficient of material B and so on, Ceiling Leak Under Bathroom and similarly for vapordiffusion resistance factors and water absorption coefficients).These related coefficients are plotted against each other inFigure 8 in order to visualize any possible correlation.

If the corresponding properties are correlated, the relatedvalues of different building materials should follow some kindof curve. Between drying coefficient and vapor diffusion resistance, Ceiling Leak Under Bathroom a positive linear correlation is observable, though witha lot of scatter. Between drying coefficient and water absorption coefficient, a negative linear correlation can be found,again with significant scatter.

A weak correlation is not a surprise, Ceiling Leak Under Bathroom since all these coefficients are the result of the material’s specific pore structureand pore connectivity. Some kind of distinct correlation between drying coefficient and vapor diffusion resistanceseems to be obvious, since vapor diffusion dominates thedrying process to quite some extent. 

However, the left-sidechart in Figure 8 indicates there is only a weak correlation.Therefore, Ceiling Leak Under Bathroom the drying coefficient cannot contain exactly thesame information as the vapor diffusion resistance. It mustcontain its own, drying-specific information as well. In orderto investigate this further, the sharp-front model according toHall and Hoff (2002) and Hens (2007) is applied as follows. 

The sharp front model distinguishes between two casesthat can be treated in a simplified way. The first case comprisesstages above critical moisture content. Water transport can be Ceiling Leak Under Bathroom described by liquid conduction. The second case comprisesstages below critical moisture content. Water transport isdescribed by vapor diffusion. 

Due to the high permeabilitiesfor liquid conduction, this treatment leads to a small gradientfor liquid transport and a high gradient for vapor transport.This sharp front has given the model its name.Applying this to the drying problem leads to the modelshown in Figure 9. Assuming the drying starts above criticalmoisture content, Ceiling Leak Under Bathroom the drying rate is determined by a constantvapor transfer at the material surface. 

This process—the firstdrying phase—continues until critical moisture content isreached at the material surface. Then the surface dries outentirely and a steep moisture front is established, Ceiling Leak Under Bathroom which movesslowly into the material. The drying rate is now determined bythe vapor diffusion from the moisture front to the materialsurface.

Lead Paint Removal Certification

Ether enzyme, ferrochelatase, is also inhibited at low blood lead levels. Inhibition of ferrochelatase leads to increase free erythrocyte protoporphyrin (FEP) in the blood which can then bind to zinc to yield zinc protoporphyrin (ZPP). At a blood lead level of 50 µg/100 g or greater, nearly 100%   read more..

Emergency Board Up_Alternative To Boarding Up Wind

This handbook provides a brief overview of the types of disasters posing a potential threat to staff. NOTE: This handbook does not contain emergency procedures for cultural items. These emergency procedures are intended to assist individuals in understanding what to expect and what to do initia  read more..

Wildlife Nuisance Control

The Louisiana Department of Wildlife and Fisheries does NOT provide nuisance animal control or removal services. We do permit individuals (Nuisance Wildlife Control Operators) to provide these services for a fee. The Department maintains a list of over 100 nuisance animal trappers located across the  read more..

Remove Urine Odor From Concrete

Removing Pet Stains and Odors YOU KNOW HOW IT GOES: The minute you turn your back, your pet decides that your new carpet is the perfect place to relieve himself. You clean and clean, but you can't get rid of that smell. What can you do? For complete tips and advice on pet behavior and  read more..

How To Remove A Fire Smoke Smell From Furniture

Guidance on protecting workers in offices and similar indoor workplaces from wildfire smoke has been developed by the California Division of Occupational Safety and Health (Cal/OSHA), in consultation with technical staff from several other California agencies. This document (attached as Appendi  read more..

Storm And High Flood Damage Prevention Plan

Mold, mildew and bacteria are common following floods and other water damage. If unchecked they can lead to sanitation and health problems. The walls, floors, closets, shelves, contents-every flooded part of your house-should be thoroughly washed and disinfected.In most cases, Flood Damage Storm And High Flood Damage Prevention Plan household cleanin  read more..

OSHA Requirements For Crime Scene Cleanup

Fourth, the fact that nursing homes are subject to infection control requirements imposed by the Health Care Financing Administration (HCFA) of the U.S. Department of Health and Human Services under the Medicare and Crime Scene Cleanup OSHA Requirements For Crime Scene Cleanup Medicaid programs and to infection control requirements of states doe  read more..

How To Clean An Oven After Using A Fire Extinguish

In the early 1990s, a number of tests using direct measures of corrosion were developed. In addition to the CNET test, the cone corrosimeter and the traveling furnace tests were developed.An additional direct test was developed by the ASTM E 05.21.70 committee but it was eventually Smoke Damage How To Clean An Oven After Using A Fire Extinguish withdrawn.&n  read more..

Mildew

Bathroom Tip Places that are often or always damp can be hard to maintain completely free of mold. If there's some mold in the shower or elsewhere in the bathroom that seems to reappear, increasing ventilation (running a fan or opening a window) and cleaning more frequently will usually prevent mold  read more..

Leaking Hot Water Heater Bottom

Without a thermal expansion tank, the water pressure in a water heater could build to a very high level and cause leakage at the pressure relief valve (or pop-off valve) located on the water heater. Lime deposits could build up on a leaking pop-off valve and clog this safety device, Water Damage Leaking Hot Water Heater Bottom w  read more..