Structural Drying >> Ceiling Leak Under Bathroom

For constant boundary conditions, a homogeneous material, and a fully developed moisture profile, the signal velocity of this profile inside the material is constant over the square root of time. This is well known and frequently observed for water absorption, Ceiling Leak Under Bathroom but it applies similarly for the drying. The main difference is that the moisture profile does not develop as quickly. 

In fact it is the end of the first drying phase that is characterized by the completed development of a distinct moisture profile. Once this profile is there, Ceiling Leak Under Bathroom the end of the drying processshould only depend on the signal velocity and the height of thematerial sample. 

The duration of the second drying phasemust, therefore, increase quadratically with the sample height,provided that the drying was started at a moisture contentsufficiently high to allow a clear distinction between first andsecond drying phases.This was investigated by a simulation study on drying offour different materials: calcium silicate brick, ceramic brick, aerated autoclaved concrete, Ceiling Leak Under Bathroom and calcium silicate insulation.

The material properties were taken from Scheffler (2008). The drying was calculated one-dimensionally for different sampleheights with constant boundary conditions of 20°C (68°F) and50% RH. It was started at effective saturation. The results are presented in Figure 7. The left chart shows the total dryingduration versus sample height; Ceiling Leak Under Bathroom the right chart shows only thesecond drying phase duration versus sample height.

The results confirm the above reasoning. The duration of the second drying phase increases quadratically with the sample height. In other words, Ceiling Leak Under Bathroom the square root of the second drying phase duration plotted versus sample height gives a linear relation (see right-side chart of Figure 7).

We therefore propose the following relation (Equation 3) as the definition of the new drying coefficient for building Ceiling Leak Under Bathroom materials: (3)where= drying coefficient in = drying time of the second drying phase in = sample height in The second drying phase duration is the timebetween the deviation from the linear drying and the end of thedrying process (see also Figure 1). 

In other words, it is the timebetween the end of the first drying phase and the moment where the equilibrium moisture content is reached everywhere inside the sample. For measured data, Ceiling Leak Under Bathroom this depends on the frequency of measurement as well as the boundary temperature and relative humidity and might, therefore, be susceptibleto error. 

It is proposed to use calculation results of the dryingprocess normalized to standard conditions. From such data, Ceiling Leak Under Bathroom the second drying phase duration can be easily determined. For most materials, the first drying phase duration isnegligible in the overall drying time. This allows simplifyingthe found relationship to be true also for the total drying timeand not only for the second drying phase duration for which itis strictly correct. 

The left-side chart in Figure 7 shows thetotal drying time versus sample height. The linear relationshipholds for all materials except the calcium silicate insulation, Ceiling Leak Under Bathroom which has a very high porosity (90%) and a very long firstdrying phase. This new drying coefficient gives a measure for the timeit takes to one-dimensionally dry out one meter of material. 

Asdiscussed before, Ceiling Leak Under Bathroom for most building materials this is correct forthe total drying time even though it is strictly only valid for thesecond drying phase. Example values for drying coefficientsof typical building materials are given in Table 2.Discussion of the Proposed Drying CoefficientThe drying coefficient gives a measure of the timerequired to dry out 1 m of material. 

By that, it has a particularmeaning and is a practically useful material parameter. Thequestion is now, Ceiling Leak Under Bathroom however, whether this parameter contains additional information in comparison with the other two moisture transport parameters, i.e., vapor diffusion resistance andwater absorption coefficient. 

For that reason, these coefficients were related to each other for numerous building materials (drying coefficient of material A divided by dryingcoefficient of material B and so on, Ceiling Leak Under Bathroom and similarly for vapordiffusion resistance factors and water absorption coefficients).These related coefficients are plotted against each other inFigure 8 in order to visualize any possible correlation.

If the corresponding properties are correlated, the relatedvalues of different building materials should follow some kindof curve. Between drying coefficient and vapor diffusion resistance, Ceiling Leak Under Bathroom a positive linear correlation is observable, though witha lot of scatter. Between drying coefficient and water absorption coefficient, a negative linear correlation can be found,again with significant scatter.

A weak correlation is not a surprise, Ceiling Leak Under Bathroom since all these coefficients are the result of the material’s specific pore structureand pore connectivity. Some kind of distinct correlation between drying coefficient and vapor diffusion resistanceseems to be obvious, since vapor diffusion dominates thedrying process to quite some extent. 

However, the left-sidechart in Figure 8 indicates there is only a weak correlation.Therefore, Ceiling Leak Under Bathroom the drying coefficient cannot contain exactly thesame information as the vapor diffusion resistance. It mustcontain its own, drying-specific information as well. In orderto investigate this further, the sharp-front model according toHall and Hoff (2002) and Hens (2007) is applied as follows. 

The sharp front model distinguishes between two casesthat can be treated in a simplified way. The first case comprisesstages above critical moisture content. Water transport can be Ceiling Leak Under Bathroom described by liquid conduction. The second case comprisesstages below critical moisture content. Water transport isdescribed by vapor diffusion. 

Due to the high permeabilitiesfor liquid conduction, this treatment leads to a small gradientfor liquid transport and a high gradient for vapor transport.This sharp front has given the model its name.Applying this to the drying problem leads to the modelshown in Figure 9. Assuming the drying starts above criticalmoisture content, Ceiling Leak Under Bathroom the drying rate is determined by a constantvapor transfer at the material surface. 

This process—the firstdrying phase—continues until critical moisture content isreached at the material surface. Then the surface dries outentirely and a steep moisture front is established, Ceiling Leak Under Bathroom which movesslowly into the material. The drying rate is now determined bythe vapor diffusion from the moisture front to the materialsurface.

Dealing With Frozen Pipes

Keep open cabinet doors leading to exposed pipes (such as access doors for sinks), so that household air can warm them.The natural flow of warmer air will help combat many problems.If you have an attached garage, keep its doors shut.Occasionally, plumbing is routed through this unheated space, Water Damage Dealing With Frozen Pipes&  read more..

Starting A Crime Scene Cleanup Business In New Yor

In any discussion of the risk to employees in the blood and plasma centers it is important to note that these facilities dedicate a substantial amount of their resources to identifying these contaminated units and ensuring that they are not released for transfusion or Crime Scene Cleanup Starting A Crime Scene Cleanup Business In New Yor for other use.&n  read more..

How To Remove Smoke Smell From Your House

Diseases of the circulatory system include high blood pressure, cardiovascular diseases, such as coronary artery disease and congestive heart failure, and cerebrovascular conditions, such as hardening of the arteries (atherosclerosis) that bring blood to the brain. These chronic conditions can rende  read more..

How To Get Rid Of Dead Animal Odor

Sulfide is a colorless, flammable, extremely hazardous gas with a "rotten egg" smell. Some common names for the gas include sewer gas, stink damp,swamp gas and manure gas. It occurs naturally in crude petroleum, natural gas,and hot springs. In addition, hydrogen sulfide is produced by bacterial brea  read more..

Mold Mitigation

If there has been a lot of water damage, and/or mold growth covers more than 10 square feet, consult EPA's Mold Remediation in Schools and Commercial Buildings. Although focused on schools and commercial buildings, this Water Damage Mold Mitigation document is applicable to other building types. If you choose to hire  read more..

Basement Drying

Recent radio and television hype about Mold Remediation Basement Drying many times creates an unusual and undue worry about contact to this mold. In the workplace many times the employees will a credit wide ranges of symptoms do to mold. These employees will accuse their made up illness even when there is no signs of ac  read more..

Tenant Trash Removal

BEFORE YOU RENT Before signing a lease agreement, prospective tenants should carefully read the lease and be sure they understand all of the requirements, provisions, rules, addendums, and laws that apply. If you have a question, ask the landlord and make sure you understand the answer, Tenant Move Out Cleanup Tenant Trash Removal and tha  read more..

How To Read A Radon Test

COMPLY WITH EPA REQUESTS FOR INFORMATION All applicants and participants must provide EPA with information upon request. This compliance is an entrance and continuing requirement of the Radon Proficiency Program. Requests to participants, especially measurement service providers, Radon Mitigation How To Read A Radon Test may   read more..

Get Rid Of Trash From The Colorado Flood

In some cases, tree removal actions were either unnecessarily expensive or later found to be ineligible. In another case, state prisoners were used to help the elderly and disabled to get their debris out to curbside, and the cost of this assistance was disqualified. A review of 36 recent OIG audits  read more..

How To Clean Electronic Switches

Parts represent inherently high risk or unknown risk because of the lack of formalized reliability assessment, screening and qualification. Also, there is little dependable data or flight history available for them as the continuous changes in design, materials and Electronic Restoration How To Clean Electronic Switches manufacturing proce  read more..