Structural Drying >> Roof Leak Diverter

Focus on high value items that were not water impacted and items that have special significance. If an entire item cannot be saved, consider parts that could be saved. For example, if a family heirloom such as an antique chest cannot be saved, consider saving the non-porous handles Roof Leak Diverter or hinges for use on a replacement piece.

Porous items that were not water logged or moldy should be the second priority. Non-porous items such as glassware, silverware, Roof Leak Diverter and plastic furniture that need to be cleaned should be separated. (Note: Contaminated items should be cleaned on site if possible. Transporting wet/contaminated items presents the risk of cross contamination of the vehicle and location where the item is moved.)

Be aware of termites. If a termite infestation is found, consult a professional exterminator. When discarding or salvaging wood, paper, Roof Leak Diverter and other cellulose, protect your property and keep Formosan subterranean termites from spreading. For additional information, refer to the Louisiana Ag Center. Facilitate restoration Do what you can to salvage the contents on the property.

See American Red Cross, Repairing Your Flooded Home, Roof Leak Diverter http://www.redcross.org/services/disaster/0,1082,0_570_,00.html Get help The following resources may be useful in providing technical support during your recovery from a flooding event: -American Red Cross (http://www.redcross.org) -FEMA (http://www.fema.gov) -Association of Specialists in Cleaning & Restoration (http://www.ascr.org) -

Louisiana State University AgCenter - Cooperative Extension Service Roof Leak Diverter (http://www.LouisianaFloods.org) -National Association of Home Builders (http://www.nahb.org/category.aspx?sectionID=843) -National Association of the Remodeling Industry (http://www.nari.org)

The following resources may be useful in providing financial and/or Roof Leak Diverter psychological support during your recovery from a flooding event: -American Red Cross (http://www.redcross.org) -Salvation Army (http://www.salvationarmyusa.org/usn/www_usn.nsf) -FEMA (http://www.fema.gov) -Small Business Administration (http://www.sba.gov)

State/local health departments - such as the North Carolina Department of Health and Human Services (http://www.dhhs.state.nc.us/docs/hurricaneoccupant.htm) [end of Recovery Advisory] Attachment of Brick Veneer in High-Wind Regions Hurricane Katrina Recovery Advisory FEMA December 2005 Purpose: To Roof Leak Diverter recommend practices for installing brick veneer that will enhance wind resistance in high-wind areas. 

Key Issues Brick veneer is frequently blown off walls of residential and commercial buildings (Figure 1). When brick veneer fails, Roof Leak Diverter wind-driven water can enter and damage buildings, and building occupants can be vulnerable to injury from windborne debris (particularly if walls are sheathed with plastic foam insulation or wood fiberboard in lieu of wood panels). 

Pedestrians in the vicinity of damaged walls can also be vulnerable to injury from falling veneer (Figure 2). Figure 1. Failed brick veneer. Plastic foam wall sheathing Roof Leak Diverter was installed over the wood studs (plywood was temporarily installed after the brick failure). Figure 2. The upper portion of the brick veneer at this apartment building collapsed. 

Pedestrian and vehicular traffic in the vicinity of the damaged wall were vulnerable to injury and damage if remaining portions of the wall were to collapse during subsequent storms. Common failure modes include tie (anchor) fastener pull-out (Figure 3), failure of masons to embed ties into the mortar (Figure 4), Roof Leak Diverter poor bonding between ties and mortar and mortar of poor quality (Figure 5), and tie corrosion (Figure 6). Figure 3. 

This tie remained embedded in the mortar joint while the smooth-shank nail pulled from the stud. Figure 4. These four ties were never embedded into the mortar joint. Figure 5. This tie was embedded in the mortar, Roof Leak Diverter but the bond was poor. Figure 6. There were several ties in this portion of the wall, but they failed due to severe corrosion.

Ties are often installed before brick laying begins. When this is done, ties are often improperly placed above or below the mortar joints. When misaligned, the ties must be angled up Roof Leak Diverter or down in order for the ties to be embedded into the mortar joints (Figure 7). Misalignment not only reduces embedment depth but also reduces the effectiveness of the ties because wind forces do not act parallel to the ties themselves. Figure 7. 

Misalignment of the tie reduces the embedment and promotes veneer failure. Corrugated ties typically used in residential veneer construction provide little resistance to compressive loads. Use of compression struts would likely be beneficial, Roof Leak Diverter but off-the-shelf devices do not currently exist. Two-piece adjustable ties (Figure 8) provide significantly greater compressive strength than corrugated ties. Figure 8. 

Examples of two-piece adjustable ties, one showing base and vee anchor and the other showing eye Roof Leak Diverter and pintle anchor. Many buildings that exhibited damaged veneer were not in compliance with current building codes. Building code requirements for brick veneer have changed over the years. Model codes prior to 1995 permitted brick veneer in any location, with no wind speed restrictions. 

Wall area per tie in some model codes was greater than the current maximum. The current masonry code referenced in model building codes, Roof Leak Diverter Building Code Requirements for Masonry Structures, ACI 530/ASCE 5/TMS 402 (ACI 530) addresses brick veneer in two manners: rational design and prescriptive requirements. 

Essentially all brick veneer in residential Roof Leak Diverter and low-rise construction follows the prescriptive requirements. The first edition of American Concrete Institute's (ACI's) 530 limited the use of prescriptive design to areas with a basic wind speed of 110 mph or less. The 2005 edition of ACI 530 extended the prescriptive requirements to include a basic wind speed of 130 mph, with lower area per tie limits. 

In locations with a basic wind speed above 130 mph, Roof Leak Diverter the rational design approach must be used. Compliance with ACI 530-05 should reduce wind damage. The following Brick Industry Association (BIA) Technical Notes provide guidance on brick veneer: Technical Notes 28 Anchored Brick Veneer, Wood Frame Construction, Technical Notes 28B  

Brick Veneer/Steel Stud Walls, and Technical Notes 44B Wall Ties (available online at www.bia.org). These Technical Notes provide attachment recommendations, but the recommendations are not specific for high-wind regions and are, Roof Leak Diverter therefore, inadequate.The brick veneer wall system is complex in its behavior. 

There are limited test data on which to draw. The following guidance is based on professional judgment, Roof Leak Diverter wind loads specified in ASCE 7-02 "Design Loads for Buildings and Other Structures," fastener strengths specified in the American Forest and Paper Association's (AF&PA's) National Design Specification for Wood Construction, and brick veneer standards contained in ACI 530-

Lead Paint Removal From A Public Building

"Public building" means a structure which is generally accessible to the public, including but not limited to, schools, daycare centers, museums, airports, hospitals, stores, convention centers, government facilities, office buildings and any other building which is not an industrial building or&nbs  read more..

Tools For Restoring Water Damaged Electronics

The electrochemical process involves deposition of a suitable conductive seed layer inside the porous slug.This layer is electrically contacted and the slug is dipped in a doped monomer solution. Electric current is passed through the seed layer into the doped monomer solution stimulating the oxidat  read more..

Radon Gas Measurement Methods

AC - Activated Charcoal Adsorption For this method, an airtight container with activated charcoal is opened in the area to be sampled and radon in the air adsorbs onto the charcoal granules. At the end of the sampling period, the container is sealed and may be sent to a laboratory for analysis.The g  read more..

How To Clean Smoke And Soot After A Fire

Ozone is a harmful air pollutant that is the main ingredient of ground-level smog. Breathing ozone can be harmful, especially for children, the elderly, and people with asthma, emphysema,bronchitis, or other respiratory diseases. Ozone irritates the eyes, nose, and throat, and Smoke Damage How To Clean Smoke And Soot After A Fire may tri  read more..

Recovering Hurricane Irene

Recovery from Hurricane Irene Steps to take before returning to homes or schoolsChildren, and whenever possible teens, should not be involved in clean-up efforts but can returnonce areas are cleaned. Children should be the last group to return Water Damage Recovering Hurricane Irene to areas impacted by flooding.

  read more..

How To Clean Up After Fire Damage

The correlation is even stronger than just by the day of test. Because each test had a 250 nm probe and a 4500 nm probe, the test-to-test correlation was strong as seen in Figure 11. The strength of the correlation seems to reinforce the variability in the performance of the material and not just un  read more..

Sewage And Floodwaters Contains Bacteria

Sewage and floodwaters contains bacteria, fecal material, viruses and other hazardous microorganisms, which can cause disease. These "germs" can be transmitted by touching contaminated items or by tracking them into uncontaminated areas on shoes. Children and pets are especially vulnerable. Odors fr  read more..

Mold Allergy Symptoms

Due to excessive rainfall this winter many Californians are experiencing increased exposure to indoor microorganisms. Several fungal species capable of producing toxic substances have been found in water-damaged California homes and offices. This article provides information about potential health e  read more..

How To Repair A Fire Damaged Wood Floor

Each year the National Fire Protection Association’s (NFPA) Standards Council recognizes individuals for outstanding service to the organization in the development of codes and Fire Damage How To Repair A Fire Damaged Wood Floor standards. Awards will be presented to 35 individuals at the World Safety Conference & Exposition ® taking   read more..

The Effects Of Breathing Raw Sewage

Therefore, the monitoring and control of VSCs including H2S from the sewer could be the most important task to reduce public odor complaints about the sewer system.Recently, a few researchers have successfully applied on-line total reduced sulfur (TRS) analyzers for the monitoring of sulfur emission  read more..