To avoid wind and windborne debris damage to rooftop ductwork, it is recommended that ductwork not be installed on the roof (see Figure 5). If ductwork is installed on the roof, it is recommended that the gauge of the ducts and their attachment be sufficient to resist the design wind loads. Figure 5 caption. Two large openings remained (circled area and inset to the right) after the ductwork on Structural Drying Wet Carpet this roof blew away. 

Condensers: In lieu of placing rooftop-mounted condensers on wood sleepers resting on the roof (see Figure 6), Structural Drying Wet Carpet it is recommended that condensers be anchored to equipment stands. (Note: the attachment of the stand to the roof deck also needs to be designed to resist the design loads.) 

In addition to anchoring the base of the condenser to the stand, Structural Drying Wet Carpet two metal straps with two side-by-side #14 screws or bolts at each strap end are recommended (see Figure 7).Figure 6 caption. Sleeper-mounted condensers displaced by high winds. [end of caption] Figure 7 caption. This condenser had supplemental securement straps (see arrows). 

Two side-by-side screws with the proper edge and end distances are recommended at the end of the strap. Vibration Isolators: When equipment is mounted on vibration isolators, an isolator that has sufficient resistance to meet the design uplift loads should be specified and installed, Structural Drying Wet Carpet or an alternative means to accommodate uplift resistance should be provided (see Figure 8).

The equipment on this stand was resting on vibration isolators that provided lateral resistance Structural Drying Wet Carpet but no uplift resistance (above). A damaged vibration isolator is shown in the inset (left). [end of caption]Access Panel Attachment: Access panels frequently blow off. To minimize blow-off of access panels, job-site modification will typically be necessary (for example, the attachment of hasps and locking devices such as a carabiner). 

The modification details will need to be tailored for the equipment, Structural Drying Wet Carpet which may necessitate detail design after the equipment has been delivered to the job site. Modification details should be approved by the equipment manufacturer.Equipment Screens: Equipment screens around rooftop equipment are frequently blown away (see Figure 9). 

Equipment screens should be designed to resist the wind loads derived from ASCE 7.Note: The extent that screens may reduce or increase wind loads on equipment is unknown. Therefore, Structural Drying Wet Carpet the equipment behind screens should be designed to resist the loads previously noted.Figure 9 caption. Several of the equipment screen panels were blown away. 

Loose panels can break glazing and puncture roof membranes. Other resources: Three publications pertaining to seismic restraint of equipment provide general information on fasteners and edge distances: Structural Drying Wet Carpet Installing Seismic Restraints for Mechanical Equipment (FEMA 412)  

Installing Seismic Restraints for Electrical Equipment (FEMA 413) Installing Seismic Restraints for Duct and Pipe (FEMA 414)[end text box] Rooftop Attachment of Lightning Protection Systems in High-Wind Regions Hurricane Katrina Recovery Advisory FEMA May 2006, Revised July 2006 Purpose: To recommend practices for Structural Drying Wet Carpet installing lightning protection systems (LPS) that will enhance wind resistance in high-wind regions.Key Issues 

Lightning protection systems frequently become disconnected from rooftops during hurricanes. Displaced LPS components can puncture and tear roof coverings, Structural Drying Wet Carpet thus allowing water to leak into buildings (see Figures 1 and 2). Also, when displaced, the LPS is no longer capable of providing lightning protection in the vicinity of the displaced conductors ("cables") and air terminals ("lightning rods"). Figure 1 caption: 

This displaced air terminal punctured the membrane in several locations. [end of Figure 1 caption] Figure 2 caption: View of an abraded end of a Structural Drying Wet Carpet conductor that became disconnected. [end of Figure 2 caption] Lightning protection standards such as NFPA 780 and UL 96A currently provide inadequate guidance for attachment of LPS to rooftops in high-wind regions. 

Some LPS manufacturers provide guidance for attachment, while other manufacturers refer to the roofing material manufacturer for attachment guidance. Some roofing material manufacturers provide guidance for attachment, Structural Drying Wet Carpet while other manufacturers refer to the LPS manufacturer for attachment guidance. 

In most cases, the attachment guidance provided by LPS and roofing material manufacturers is inadequate for hurricane-prone regions. LPS conductors are typically attached to the roof at 3 foot intervals. Because the conductors are flexible, Structural Drying Wet Carpet when they are exposed to high winds, the conductors exert dynamic loads on the conductor connectors ("clips"). Guidance for calculating the dynamic loads does not exist. 

The attachment guidance that follows is therefore based on professional judgment. LPS conductor connectors typically have prongs to anchor the conductor. When the connector is well-attached to the roof surface, Structural Drying Wet Carpet during high winds the conductor frequently bends back the malleable connector prongs (see Figure 3). 

Conductor connectors have also debonded from roof surfaces during high winds. Based on observations after Hurricane Katrina and other hurricanes, Structural Drying Wet Carpet it is apparent that pronged conductor connectors do not provide reliable attachment.Figure 3 caption: During high winds, the conductor deformed the prongs and pulled away from this conductor connector. 
 

Construction Guidance Parapet attachment: When the parapet is 12-inch high or greater, it is recommended that the air terminal base plates Structural Drying Wet Carpet and conductor connectors be mechanically attached with #12 screws that have 1.25 inch minimum embedment into the inside face of the parapet nailer and properly sealed for watertight protection. 

In lieu of conductor connectors that have prongs, it is recommended that mechanically attached looped connectors be installed (see Figure 4). Figure 4 caption: This conductor was attached to the coping with a looped connector (above). However, Structural Drying Wet Carpet a gasket was not installed between the connector and the coping. 

Also, because the connector screws were too short to engage the wood nailer, the screws pulled out and the conductor was displaced in some areas. Attachment to built-up, modified bitumen and single-ply membranes: For built-up and modified bitumen membranes, Structural Drying Wet Carpet attach air terminal base plates with asphalt roof cement. 

For single-ply membranes, attach air terminal base plates with pourable sealer (type recommended by the membrane manufacturer). In lieu of attaching conductors with conductor connectors, Structural Drying Wet Carpet it is recommended that conductors be attached with strips of membrane installed by the roofing contractor. 

For built-up and modified bitumen membranes, use strips of modified bitumen cap sheet, approximately 9-inch wide minimum. For single-ply membranes, use self-adhering flashing strips, approximately 9" wide minimum. If strips are torch-applied, Structural Drying Wet Carpet avoid overheating the conductors. Start the strips approximately 3 inches from either side of the air terminal base plates. Place strips that are approximately 3' long, followed by a gap of approximately 3 inches.

How Do I Clean Up After The Finished Basement Floo

Basement and Yard Water Problems
 Each year, the Water Resources Center receives dozens of phone calls and emails from people experiencing problems with unwanted water. Many of the calls start Basement Drying How Do I Clean Up After The Finished Basement Floo with "I think my house is built on a spring”. The symptoms may include w  read more..

Mold Detector

Assess the size of the mold and/or moisture problem and the type of damaged materials before planning the remediation work. Select a remediation manager for medium or large jobs (or small jobs requiring more than one person). The remediation plan should include steps to fix the water or moisture pro  read more..

Microburst Vs Tornado

Major wind damage In Albemarle, Stanly County caused by a Microburst National Weather Service, Raleigh, NC Report prepared on June 14, 2013 A microburst caused by a severe thunderstorm impacted Stanly County, including the city of Albemarle and surrounding areas, Wind Damage Microburst Vs Tornado on Thursday, June 13,  read more..

Remove The Musty Smell From A Basement After Water

Exterior wall insulation must be approved for below-grade use. Typically, three products are used below grade: extruded polystyrene, expanded polystyrene, and rigid mineral fiber panels. (Baechler et al. 2005). Basement Drying Remove The Musty Smell From A Basement After Water Extruded polystyrene (nominal R-5 per inch) is a common choice.    read more..

Flood Water Extraction And Mold Cleanup

Molds are microscopic organisms found everywhere in the environment, indoors and outdoors. When present in large quantities,Flood Damage Flood Water Extraction And Mold Cleanup  molds have the potential to cause adverse health effects. 

Health Effects of Mold Exposure Sneezing Cough and congestion Runny   read more..

Best Way To Prevent Lead Poisoning

The best way to prevent all forms of  lead related impairments and diseases (both short term and long term) is to maintain your PbB below 40 µg/100 g. The provisions of the standard are designed with this end in mind. Your employer has prime responsibility to assure that the provisions of th  read more..

How To Repair Fire And Water Damage

Five members of Congress were recognized this month by the National Fire Protection Association (NFPA) for their exemplary work relating to fire service activities.Honored as NFPA Legislator of the Yearfor distinguished achievements from last year were Congressman Bob Etheridge of North Carolina; Co  read more..

Frozen Pipe Burst Prevention

Cold Weather TipsGuard Against Cold DraftsSince most water meters and pipes are located in unheated areas, they are vulnerable when temperatures dip below freezing. Even a small draft of cold air through a cracked basement window, Water Damage Frozen Pipe Burst Prevention foundation or sill during extremely cold periods could  read more..

F5 Tornado Facts

As the cold pool elongates, repetitive storm growth on the downwind-moving, progressive part of the gust front comprises the derecho-producing convective system (red arc in bottom cross section of figure below, and Wind Damage F5 Tornado Facts on right side of plan view inset). 

Meanwh  read more..

Remove Radon Gas From A Home

Biennial Measurement Exam The Measurement Exam was updated in July 1994 to include the latest in technological and procedural advancements. The biennial measurement exam will continue to be offered concurrently with the continuing education courses until August 15, 1997, and participants whose renew  read more..