Mold Remediation >> Mold Mitigation & Remediation

Testing is usually done to compare the levels and types of mold spores found inside the building with those found outside of the building or for comparison with another location in the building. In addition, Mold Mitigation & Remediation air sampling may provide tangible evidence supporting a hypothesis that investigators have formulated. For example, air sampling may show a higher concentration of the same species of mold when the HVAC is operating than when it has been turned off. 

This finding may convince the investigators that the mold is growing within, and being disseminated by, the HVAC system. Conversely, Mold Mitigation & Remediation negative results may persuade investigators to abandon this hypothesis and to consider other sources of mold growth or dissemination. 

If you know you have a mold problem, it is more important to spend time and resources removing the mold and solving the moisture problem that causes the moldy conditions than to undertake extensive testing for the type and Mold Mitigation & Remediation quantity of mold.

If you are in doubt about sampling, consult an industrial hygienist or other environmental health Mold Mitigation & Remediation or safety professional with experience in microbial investigations to help you decide if sampling for mold is necessary or useful, and to identify persons who can conduct any necessary sampling. Due to the wide difference in individual susceptibility to mold contamination, sampling results sampling may have limited application. 

However, sampling results can be used as a guide to determine the extent of an infestation and the effectiveness of the cleanup. Their interpretation is best left to the industrial hygienist Mold Mitigation & Remediation or other environmental health or safety professional.Sampling for mold should be conducted by professionals with specific experience in designing mold-sampling protocols, sampling methods for microbial contaminants, and interpretation of results. 

For additional information on air sampling, refer to the American Conference of Governmental Industrial Hygienists' document, "Bioaerosols: Assessment and Control." In addition, sampling and analysis should follow any other methods recommended by either OSHA, NIOSH, EPA, the American Industrial Hygiene Association, Mold Mitigation & Remediation or other recognized professional guidelines. 

Types of samples can include: air samples, surface samples, bulk samples, and Mold Mitigation & Remediation water samples from condensate drain pans or cooling towers. Microscopic identification of the spores/ colonies requires considerable expertise. These services are not routinely available from commercial laboratories. 

Documented quality control in the laboratories used for analysis of the bulk, surface, Mold Mitigation & Remediation and other air samples is necessary. The American Industrial Hygiene Association offers accreditation to microbial laboratories (Environmental Microbiology Laboratory Accreditation Program (EMLAP)). Accredited laboratories must participate in quarterly proficiency testing (Environmental Microbiology Proficiency Analytical Testing Program (EMPAT)). 

Remediation Equipment There are various types of equipment useful in mold assessment Mold Mitigation & Remediation and remediation. Some of the more common items include: Moisture Meters Moisture meters measure/monitor moisture levels in building materials, and may be helpful for measuring the moisture content in a variety of building materials following water damage. 

They also can be used to monitor the progress of drying damaged materials. These direct reading devices have a thin probe that is inserted into the material to be tested Mold Mitigation & Remediation or pressed directly against the surface of the material. Moisture meters can be used on materials such as carpet, wallboard, wood, brick, and concrete.

Humidity Gauges or Meters Humidity meters can be used to monitor indoor humidity. Inexpensive (less than $50) models that monitor both temperature and humidity are available. Humidistat A humidistat is a control device that can be connected to an HVAC system and adjusted so that if the humidity level rises above a set point, Mold Mitigation & Remediation the HVAC system will automatically turn on and reduce the humidity below the established point.

Boroscope A boroscope is a hand-held tool that allows users to see potential mold problems inside walls, Mold Mitigation & Remediation ceiling plenums, crawl spaces, and other tight areas. It consists of a video camera on the end of a flexible "snake." No major drilling or cutting of dry wall is required. 

HVAC System Filter High-quality filters must be used in a HVAC system during remediation because conventional HVAC filters are typically not effective in filtering particles the size of mold spores. Consult an engineer for the appropriate filter efficiency for your specific HVAC system, Mold Mitigation & Remediation and consider upgrading your filters if necessary. 

A filter with a minimum efficiency of 50 to 60% or a rating of MERV 8, as determined by Test Standard 52.2 of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Mold Mitigation & Remediation may be appropriate. Remember to change filters as appropriate, especially following any remediation activities. 

Remove filters in a manner that minimizes the reentry of mold and other toxic substances into the workplace. Under certain circumstances, Mold Mitigation & Remediation it may be necessary to wear appropriate PPE while performing this task.How Do You Know When You Have Finished Remediation/Cleanup? You must have identified and completely corrected the source of the water or moisture problem.

Mold removal should be complete. Visible mold, mold-damaged materials, and moldy odors should no longer be present.Sampling, if conducted, should show that the level Mold Mitigation & Remediation and types of mold and mold spores inside the building are similar to those found outside.You should revisit the site(s) after remediation, and it should show no signs of moldy or musty odors, water damage, or mold growth.

After correcting water or moisture infiltration, the prompt removal of contaminated material and structural repair is the primary response to mold contamination in buildings. In all situations, Mold Mitigation & Remediation the underlying cause of water accumulation must be rectified or the mold growth will reoccur. Emphasis should be placed on preventing contamination through proper building and HVAC system maintenance and prompt repair of water damaged areas.

Effective communication with building occupants is an essential component of all large-scale remediation efforts. The building owner, management, and/or employer should notify occupants in the affected area(s) of the Mold Mitigation & Remediation presence of mold. Notification should include a description of the remedial measures to be taken and a timetable for completion. 

Group meetings held before and after remediation with full disclosure of plans and results can be an effective communication mechanism. Individuals with persistent health problems that appear to be related to mold exposure should see their physicians for a referral to practitioners who are trained in occupational/environmental medicine Mold Mitigation & Remediation or related specialties and are knowledgeable about these types of exposures.

How To Repair Smoke Damage From Fire

For the second time this month, Fire Damage How To Repair Smoke Damage From Fire another state joined the national movement to enhance public safety by mandating that all cigarettes sold in their state be "fire-safe.” Such cigarettes are less likely to ignite fires if dropped or carelessly discarded.

Tod  read more..

Drying Techniques From Flood

The impact of Hurricane Sandy extended far beyond the structures destroyed by the storm surge. Although the water has receded and most structures have been pumped out, Structural Drying Drying Techniques From Flood the large number of properties that need repair means that restoration will go on for months.

  read more..

Remove Smoke Odor From Fabric

Anaerobic digesters are designed to optimize waste degradation and capture the gaseous by-products, primarily carbon dioxide and methane. Methane can be used on-farm for heating through a furnace or in electricity production. Mesophilic digesters are the most common type, and support a bacterial pop  read more..

Leaking Toilet Base

Burst Pipe Floods Basement Areas On the front page...Late Tuesday evening, June 26, the Clinical Center experienced one of the worst floods in its history when a water booster pump vibration eliminator on a chilled- water pipe burst and ran for 40 minutes before it was detected Water Damage Leaking Toilet Base and st  read more..

Crime Trauma Scene Decontamination Training

CRIME SCENE WASTE A. If the crime has occurred on an Individual Parcel, the Police Department will advise the responsible party to contact a private cleanup company. Crime Scene Cleanup Crime Trauma Scene Decontamination Training The list of city approved cleanup firms may be provided upon request. 

If a police inc  read more..

Can Lead Poisoning Be Treated ?

Can lead poisoning be treated? Yes, however, the best approach is to stop your children from coming into contact with lead. The most common way to treat lead poisoning in children is to find the lead source and remove it from their environment. Few children have high enough levels of lead in thei  read more..

How To Stop Water And Mold In A Crawlspace

Many molds produce numerous protein or glycoprotein allergens capable of causing allergic reactions in people. These allergens have been measured in spores as well as in other fungal fragments. An estimated 6%-10% of the general population and Crawl Space Drying How To Stop Water And Mold In A Crawlspace 15%-50% of those who are genetically susc  read more..

Water Extraction

Electronic data base consists of all the material that is Kept as Document restoration Water Extraction in your businesses office and the attempted prevention of the loss of this valuable electronic data base will depend on the routine daily backing-up of all computer server files. The section of material and instructional sk  read more..

How To Remove Asbestos Contaminated Vermiculite

Hygiene facilities and practices -- Change rooms. The employer shall provide clean change rooms for employees who work in areas where their airborne exposure to asbestos is above the TWA and/or excursion limit. The employer shall ensure that change rooms are in accordance with 1910.141(e) of this&nb  read more..

EPA Contractors Mold Requirements

In order to limit your exposure to airborne mold, you may want to wear an N-95 respirator, available at many hardware stores and from companies that advertise on the Internet. (They cost about $12 to $25.) Some N-95 respirators resemble a paper dust mask with a nozzle on the front, others are made p  read more..