Biennial Mitigation Exam The mitigation exam was updated in July 1994 to include the latest policy, protocol and technical information. The mitigation exam will be offered in lieu of completing the new biennial continuing education requirement until August 15, 1997, and participants whose renewal date is before this date have the option of taking the re-exam or Get Rid Of Radon In Your House completing CE to fulfill their biennial program requirements. 

At that time, all existing residential mitigation service providers will have had the opportunity to take the "updated” exam. After August15, 1997, the biennial exam will be eliminated. As referenced in Section 5.1.2, the exam is offered in CBT and Get Rid Of Radon In Your House paper-and-pencil formats. To schedule the CBT exam, call 1-800-828-EXAM (3926). 

You must contact your local RRTC directly to schedule paper and-pencil exams. If you need further assistance, please contact the RIS (see Section 2.1). PROFICIENCY LISTINGS This section of the Handbook reviews the meaning and content of participant listings, Get Rid Of Radon In Your House as well as how listings are made available to participants, states, and the interested public. 

An EPA listing includes Get Rid Of Radon In Your House information that is needed to inform consumers or states about a participant's status in the Program. Listings are continuously updated to reflect a participant's most current status. For example, the Agency will update listings to accountfor all device performance tests, the addition of new services, or a change in the participant's phone number.

Updated Get Rid Of Radon In Your House information is maintained in the Agency's records at all times. Information on the availability of Proficiency Listings is found in Section 6.2.The Proficiency Listings are divided into three sections which are broken down by service type. The Analytical Measurement Service providers are listed by organization or individual name. 

Participant listings for analytical services show specific devices Get Rid Of Radon In Your House and their service areas for all devices in which they are currently listed. Individuals that meet requirements for Residential Measurement Service providers are listed by the participant's name. Residential Mitigation Service providers are listed in the same way as the residential measurement service providers; 

However, the mitigators appear in their own section of the Proficiency Listings.6.1 MEANING AND CONTENT OF RADON PROFICIENCY PROGRAM LISTINGS 6.1.1 General Participant Information A listed participant has met the Program requirements necessary for listing as an analytical measurement service provider, residential measurement Get Rid Of Radon In Your House and/or residential mitigation providers. 

The listing includes the participant's name (if applicable), company name, business address, telephone number, service area, Get Rid Of Radon In Your House and any other relevant information. 6.1.2 Listing for Analytical Measurement Service Providers Participants with listed devices have demonstrated the ability to measure radon accurately with a specific radon measurement device and agree to make measurements only with listed devices according to Program requirements.

The listing includes information specific to each measurement device with which the participant offersanalytical measurement services. The states and possessions served with each device (or "Nationwide" for theentire US), the device name (brand/model/type), Get Rid Of Radon In Your House and its measurement method designation are shown. 

An example of an analytical services Listing Letter appears in Exhibit 6-1.6.1.3 Residential Measurement and Residential Mitigation Service Listings Participants listed for residential services agree to follow the Get Rid Of Radon In Your House procedures outlined in this Handbook that are appropriate to their listing. 

An individual whose name appears in the Proficiency Listings may not Get Rid Of Radon In Your House misrepresent the meaning of participation in the Radon Proficiency Programs to the public. Appearing in RADON MEASUREMENT DEVICE PERFORMANCE TESTS 7.1 LABORATORIES AND DEVICE EXPOSURE 

The EPA maintains radon laboratories in Montgomery, Alabama, and Las Vegas, Nevada, Get Rid Of Radon In Your House which conductall device performance testing for the Program. Program applicants who bring their devices to the test site will be given appointments to come to one of these EPA laboratories. Applicants who mail their devices will ship them according to RQAC instructions. 

The RQAC will provide the Get Rid Of Radon In Your House address information for submitting the appropriate devices, where they will be processed and then shipped to the EPA laboratories for exposure. After exposure, the labs will return the devices to the applicant for analysis. This section of the Handbook describes both the laboratories and the general conditions under which the laboratories will expose the measurement devices.

Both EPA radon laboratories provide assistance to EPA Headquarters and Regional Offices, states, other Federal agencies, Get Rid Of Radon In Your House and the private sector in terms of: technical advice, radiological monitoring and assessment,dose and risk assessment, and maintaining emergency response capabilities. 

The radon chambers at both labs support National and International radon programs (for quality assurance) as well as projects to measure radon levels in schools, Get Rid Of Radon In Your House Federal buildings and residences. Exhibits 7-1 and 7-2 are maps showing the location of the National Air and Radiation Environmental Laboratory (NAREL) and the Las Vegas Laboratory (ORIA-LV),respectively. 

The addresses and Get Rid Of Radon In Your House telephone numbers are as follows:U.S. Environmental Protection Agency Office of Radiation and Indoor Air National Air and Radiation Environmental Laboratory 540 South Morris Avenue Montgomery, Alabama 36115-2601(334) 270-3400 U.S. Environmental Protection Agency Office of Radiation.

Indoor Air Radon Evaluation Laboratory 944 East Harmon, EAX-3Las Vegas, Nevada 89119(702) 798-31227.1.1 Laboratory Exposure Conditions The three following Get Rid Of Radon In Your House subsections describe general conditions under which devices will be exposed.The Agency will conduct four independent sample measurements for devices in most EPA method categories. 

However, in the continuous radon, continuous working level, pump-collapsible bag, and RPISU methods, Get Rid Of Radon In Your House only one measurement will be taken. The number of measurements for each of the 15 method categoriesis shown in Exhibit 7-3. It is important that radon measurement devices be able to provide reliable measurements under the unique conditions that might exist when a measurement is made by or for a consumer. 

Exhibit 7-4 shows the boundaries of environmental conditions that might exist in EPA's radon chambers during Program device performance testing. These outer boundaries are based on EPA's current estimates of environmental conditions that might exist in Get Rid Of Radon In Your House buildings throughout the country. Actual values for the parameters indicated may vary within the ranges cited. 

EPA laboratories may also Get Rid Of Radon In Your House produce condensation nuclei (CN) in their chambers to approximate consumer measurement conditions. For devices with recommended consumer exposure durations of less than two weeks, the EPA exposure period will be consistent with the recommended exposure period.

EPA realizes that many devices specify exposure periods in excess of two weeks. However, Get Rid Of Radon In Your House because all devices designed for long-term exposure are integrating devices, shorter-term measurements can be made provided total exposure is at a level above the lower limit of detection in (pCi/L)-days. 

For example, an alpha track device designed for a minimum exposure period of 90 days will perform with equivalent accuracy if exposed for only 15 days at six times that level, Get Rid Of Radon In Your House as long as the lower limit of detection is exceeded. Applying the known calibration factor to the counted track density yields the integral exposure in (pCi/L)-days, from which, using the known days of exposure, the average radon concentration in pCi/L can be determined.


 

How To Clean Sewer Overflows In Your House

Do you have a chronic sanitary sewer backup problem? The City of Decatur has a program to help stop sewer backups in your home. The Sewage Cleanup How To Clean Sewer Overflows In Your House program is available to homeowners within the City of Decatur city limits. This brochure gives overview of the "Sanitary Sewer Backup Prevention Program"  read more..

Flood Damage

Did you know the average residential house loses 14% of the water delivered to leaks? In an average home, 22 gallons of water are lost to leakage every day, and the usual suspects are leaking toilets or dripping faucets. This daily water leakage amount is ab  read more..

Mold Is Growing On The Soil In A Crawl Space

MOLD AND MOISTURE PROBLEMS IN CRAWLSPACES Introduction Some houses in Idaho and across the country have problems with standing water or moisture in the crawlspace, providing a perfect environment for mold growth and Crawl Space Drying Mold Is Growing On The Soil In A Crawl Space other moisture problems. 

For  read more..

How To Dehumidify A Bathroom Without Losing Heat

Fans shall be Class II (minimum) construction with single inlet, aluminum wheel and stamped air-foil aluminum blades. The fan wheel shall be mounted on the directly-driven motor shaft in AMCA Arrangement 4. G. Filter Section: Pleated, Dehumidification How To Dehumidify A Bathroom Without Losing Heat disposable pre-filters in outdoor-air inlets suppl  read more..

Lead Paint Removal Poisoning

Where the employer does establish that the employee is exposed to levels of lead below 2,500 µg/m3, the employer may provide the exposed employee with the appropriate respirator prescribed for use at such lower exposures, in accordance with Table I of this section. Interim protection as described i  read more..

Get Rid Of A Dead Animal Smell In The Wall

Simply banging on the ceiling, wall, or floor in the vicinity of the animal may cause it to vacate; also, your initial search for young may have already made the animal uncomfortable enough to leave.Alternatively, with a powerful flashlight or headlamp containing fresh batteries, and Odor Control Get Rid Of A Dead Animal Smell In The Wall weari  read more..

Mold And Mildew From Flash Floods

Following a widespread flooding disaster, many questions arise from citizens within the communities affected and from the many volunteers and organizations that are working in the devastated area. Personal health and safety is a priority for everyone. The following information is aimed at preventing  read more..

How To Repair Fire Damaged Concrete

Recovering from a fire can be a physically and mentally draining process.When fire strikes, lives are suddenly turned around. Often, Fire Damage How To Repair Fire Damaged Concrete the hardest part is knowing where to begin and who to contact.

The U.S. Fire Administration has gathered the following information to assist you in  read more..

Radon Boats

The sick building syndrome comprises of various nonspecific symptoms that occur in the occupants of a building. This feeling of ill health increases sickness absenteeism and causes a decrease in productivity of the workers. As this syndrome is increasingly becoming a major occupational hazard, the c  read more..

Basement Drying

Water extraction, Basement Drying