Radon Mitigation >> Know If A Radon Mitigation System Is Working

Administrative Procedures for Mail-In Tests After EPA accepts an Application for a mail-in device, the applicant will be scheduled for his or her device performance test. The RQAC will send a notice to the applicant requesting the appropriate device(s) prior to the performance test date. Applicant failure to send the devices promptly may necessitate rescheduling of device exposure, Know If A Radon Mitigation System Is Working resulting in substantial delays in listing. 

The Agency exposes the devices to radon concentrations in EPA's laboratory chambers. Depending on the method type, Know If A Radon Mitigation System Is Working applicants may have up to four separately exposed devices. After exposure, devices are returned to applicants for analysis. Devices may bereturned in one or more packages. Applicants must return their measured values within the time frame specified on the Analysis Reporting Form. 

The Agency evaluates the measured values submitted by the applicant against the Agency's test criteria, Know If A Radon Mitigation System Is Working then notifies the applicant of the results.7.2.4 Procedure for Evaluating Device Performance Test Results The criterion used in the performance test requires that the value of the individual relative error (IRE)of each radon measurement not exceed 25%. 

The success or failure of each measurement in the test is determined by comparing EPA's target value to the measured value reported to EPA by the applicant.The IRE measurement test criterion formula is:Where: IRE = absolute value of the Know If A Radon Mitigation System Is Working individual relative error for device "i," in percent, for each measurement; MVi = measured value for device "i"; and TVi = target value for device "i." 

EPA's procedure for evaluating device performance test results includes an initial test and a possible retest. In their entrance performance test, Know If A Radon Mitigation System Is Working applicants may: (1) pass; (2) fail but be eligible to complete a retest;or (3) fail to meet the retest criteria and be required to reapply. Therefore, the possible outcomes are:

Initial Test: Pass: If the results of all IRE measurements are less than or equal to (#) 25%, the applicant is eligible to be listed for that device, or the participant to remain listed.Fail/Retest: If the result of any IRE measurement is greater than (>) 25%, Know If A Radon Mitigation System Is Working but all results are#50%, then the applicant/participant is eligible to retest. 

Applicants/participants who do notpass a retest will not obtain or maintain their listing. Applicants/participants who fail an initialblind test and are eligible for a retest will be notified prior to their retest opportunity.Fail/Reapply: If the result of any IRE measurement is >50%, the applicant will not be givenan opportunity to retest, Know If A Radon Mitigation System Is Working and the Application will be dropped from consideration. 

Similarly,the participant will be ineligible for a retest and will be delisted for that device.Retest: Pass: If the results of all IRE retest measurements are #25%, the applicant/participant is eligible to be listed for that device or to remain listed, as long as other Program requirements are met. Fail/Reapply: If the result of any IRE retest measurement is >25%, the applicant will not be listed Know If A Radon Mitigation System Is Working and the Application will be dropped from consideration. 

Similarly, the participant will be ineligible for a retest and will be delisted for that device.Reapplication: Applicants/participants not meeting the #50% IRE retest eligibility requirement for the initial test, or the #25% IRE requirement for the retest, Know If A Radon Mitigation System Is Working will be dropped from the Program for that device. 

To reapply to the Program, applicants and participants must submit (1) an explanation of the problem they believe occurred during their performance test and actions taken to correct the problem; and (2) a specific description of the applicant's or Know If A Radon Mitigation System Is Working participant's calibration procedures. EPA may also require these applicants/participants to submit their QA/QC plan and/or other documents for review prior to reentering the Program.

Device Performance Test Examples In this section, the device performance test and retest use a criterion known as the absolute value of the individual relative error (IRE). In this example test, Know If A Radon Mitigation System Is Working the result for device #3 has a calculated IRE of 29%, or 4 percentage points over the 25%limit. Therefore, the applicant fails the initial test. 

However, because this 29% result is less than 50%, Know If A Radon Mitigation System Is Working the applicant can retest. If the IRE result had been less than 25% (e.g., 18%), then all four measurements would have passed the test, and—assuming that all other requirements had been met—the applicant would be listed in the Program for analytical measurement services with this device.

Example 2: This example uses a continuous radon monitor (CR) submitted by an applicant; Know If A Radon Mitigation System Is Working only one measurement is required for measurement devices in the CR method category.Device ID Codes Measured Target Absolute Value of the Individual Participant EPA Value (MV) Value (TV) Relative Error (IRE)B3875 666669 15.7 35.0 0.55 (or 55%)

In this example test, the applicant's test result has a calculated IRE of 55%, or 30 percentage points over the 25%limit. Therefore, the applicant fails the initial test. However, Know If A Radon Mitigation System Is Working because this 55% result is also greater than 50%, the applicant is not eligible for a retest and must reapply if they wish to continue participating in the Program. 

If the IRE result had been less than 50%, Know If A Radon Mitigation System Is Working then the applicant would have been eligible for a retest. If the applicant then passed the retest—assuming that all other requirements had been met—that participant would be listed in the Program with this CR device. Example 3: This example uses a continuous working level monitor (CW) submitted by an applicant; only one measurement is required for devices in the CW method category.

Device ID Codes Measured Target Absolute Value of the Individual Participant EPA Value (MV) Value (TV) Relative Error (IRE)C2222 123456 0.075 0.060 0.25 (or 25%)In this example test, the applicant's test result has a calculated IRE of 25%, Know If A Radon Mitigation System Is Working which is equal to the 25% limit. Therefore, the applicant passes the initial test and achieves listed status for analytical measurement services.

QUALIFYING RADON MEASUREMENT DEVICES FOR USE IN THE PROGRAM All devices entered into the Program must be within an RPP radon measurement method category. Analytical applicants to the Program enroll with one or Know If A Radon Mitigation System Is Working more specific radon measurement devices. Applicants may enroll in the Program immediately with any measurement device that is included in the Application Device Checklists. 

These checklists include all devices, equipment, and Know If A Radon Mitigation System Is Working instruments that EPA is currently aware of that have been used by a Program participant in passing the RPP performance test. All ofthe devices, equipment, and instruments included on the checklists are associated with one or more methodcategories. Appendix A includes brief definitions of the method categories currently accepted in the Program.

EPA's Indoor Radon and Radon Decay Product Measurement Device Protocols provides a detailed explanation of these Know If A Radon Mitigation System Is Working methods.An applicant who wishes to enroll in the RPP with a device that is not included in the Application Device

How To Remove Lead Paint From Wood

There are several ways to remove lead-based paints: Wire brushing or wet hand scraping with the aid of a non-flammable solvent or abrasive compound. Liquid paint removers can be used on small areas, such as windowsills, doors and woodwork. Read and follow the manufacturer's instructions and warning   read more..

Requirements For Workers Exposed To Lead

Requirements for Workers Exposed to Inorganic Lead Under the standard for inorganic lead in the construction industry, initial medical surveillance consisting of biological monitoring to include blood lead and ZPP level determination shall be provided to employees exposed to lead at or Lead Paint Removal Requirements For Workers Exposed To Lead abo  read more..

How To Remove Smoke Damage From Mirrors And Glass

During this process they will ingest the soot and Smoke Damage How To Remove Smoke Damage From Mirrors And Glass other byproducts of the fire which maybe quite harmful. A cat that has been in a fire should be carefully and thoroughly shampooed in lukewarm water with a mild baby shampoo. You may do this yourself but many pet owners find it less st  read more..

Remove Black Toxic Mold From The Attic

Although the level of personal protection suggested in these guidelines is based on the total surface area contaminated and the potential for remediator and/or occupant exposure, professional judgment should always play a part in remediation decisions. These remediation guidelines are based on the s  read more..

Grants For Asbestos Removal

Because asbestos was used so frequently and because of the dangers of asbestos it is possible to secure grants for Asbestos Abatement Grants For Asbestos Removal. Now the cannot be used in every case it only a select few will be eligible and the regulations will be different depending on which state you live in and which area of the   read more..

Ceilling Leak From Rain

GLOSSARY OF USEFUL TERMS Affected air the space within in a room or building which is influenced by or can influence the moisture content level of material inside that room or building. AHAM (Association of Home Appliance Manufacturers) an industry association which publishes test results for wate  read more..

Methamphetamine Cleanup

Each week an average of 300 unlawful methamphetamine laboratories are found across the United States. After law enforcement intercede, a hazardous mess still remains. From cocaine to methamphetamine, each week an average of around 300 laboratories intended to make methamphetamines are found a  read more..

The Advantages And Disadvantages Of Flood Defenses

If the code permits, it is probably best to throw away switches and outlets that were flooded and replace them with new ones. (See Step 5).

3.Check your water system for leaks from pipes that may have moved. (See Step 5). Even if your water supply is not safe to drink, it  read more..

Remove Smoke Odor After A Fire

How can I remove the smell of smoke from my books/documents? The odor from smoke is hard to eliminate, but the following tips may be helpful in removing it from your materials: Carefully wipe books with a soft cosmetic brush to remove any dirt or other particles. Dirt holds the smell to the pages. S  read more..

How To Remove Radon From A Basement

Category I Course Work As stated above, participants in the Residential Mitigation Service Provider component of the RPP must earn a minimum of eight (8) of the required sixteen (16) hours of continuing education every two years through approved Category I course work. Those with dual listings are r  read more..