In the United States, flammability requirements for electrical equipment are most commonly specified in the National Electrical Code (NEC) [12]. Specific testing requirements are then defined by testing laboratory standards (e.g., Underwriters Laboratories, Canadian Standards Association, etc.). Such standards are essentially voluntary until required by a building code,regulatory agency, Effects Of Smoke On Electronic Equipment or by the building owner as part of the bid process for construction of a facility. 

Such requirements are included in the specifications of various organizations such as the U.S. Nuclear Regulatory Commission (NRC), the Department of Defense, transportation authorities, and other large organizations. These specifications include requirements governing the allowable ignition, Effects Of Smoke On Electronic Equipment flame spread, and smoke production of materials, along with the design,installation, and use of electrical devices and systems.

In addition to direct regulation of the flammability and smoke generation properties of materials and Effects Of Smoke On Electronic Equipment equipment, there is also interest in indirect effects on the operational capabilities of personnel and equipment that may be exposed to a fire environment resulting from a fire. 

In NPP applications, Effects Of Smoke On Electronic Equipment operators must be able to perform appropriate safe shutdown operations and equipment may be critical to plant monitoring or to safe shutdown procedures so that both the direct effects of fire and indirect effects of fire generated smoke are of interest to ensure safe plant shutdown.

Considerable research has been conducted on the direct effects of fire in NPP applications [11].Recent studies have reviewed potential sub lethal effects of fire effluent [13]. A review of both direct and Effects Of Smoke On Electronic Equipment indirect effects of fire on electrical equipment [7] was also a resource for this report.

This chapter provides a review of Effects Of Smoke On Electronic Equipment studies of indirect fire effects on electrical equipment including studies specific to NPPs plus a significant base of research related to telecommunications equipment.2.1 Nuclear Power Plant Equipment 2.1.1 Susceptible Components in NPP Applications The earliest treatment of indirect fire damage to nuclear power facilities is a report prepared for the NRC by the NUS Corporation in 1985 [14]. 

The report evaluates the damaging aspects of fire environments, Effects Of Smoke On Electronic Equipment the susceptibility of various components to damage and the importance of those components to plant safety. Of particular interest was the impact of conditions associated with suppression activities (high humidity or liquid water effects).

Elevated temperatures below ignition temperatures of typical materials, and corrosion due to products from cable fire or Effects Of Smoke On Electronic Equipment gaseous suppression agents.Components were selected for evaluation based on the Fire Hazards Analysis (FHA) reports from four NPPs. Those components necessary to achieve and maintain safe-shutdown were evaluated based on Environmental Qualification (EQ) test reports and hydrogen burn tests. 

The EQ reports were used to judge resistance to elevated temperatures and high humidity or liquid water effects. The hydrogen burn tests and Effects Of Smoke On Electronic Equipment numerical simulations subjected a variety of electrical and electromechanical components to elevated temperatures, pressures and humidity caused by hydrogen fires in confined spaces. 

The hydrogen burn results indicated functionality of specific components and likely causes of failure. Based on the sources above and extensive use of engineering judgment, Effects Of Smoke On Electronic Equipment components were assigned ratings in a number of distinct categories describing damage ability and significance to plant operability. 

These ratings were weighted according to relative importance and Effects Of Smoke On Electronic Equipment combined into a single value to describe the overall hazard produced by exposing a given component to adverse environmental conditions. The primary result of these experiments is a relative ranking of components by both importance and susceptibility to fire damage. 

This information, shown in Table 1, is expressed for each component as a single number ranging from 0 to 1, Effects Of Smoke On Electronic Equipment with higher values indicating greater importance and risk of damage. Because the tests used clean burning hydrogen, the applicability of these results is limited with respect to smoke damage, but does provide guidance for identifying components that are both important to plant operation and sensitive to environmental conditions. 

It is also worth noting that this assessment applies almost exclusively to analog technology. Equipment Exposure to Full-Scale Fire Environments In response to reports of significant damage caused by so called "secondary environments”created by fires in NPP and other applications, Effects Of Smoke On Electronic Equipment Sandia National Laboratories (SNL) performed a number of cabinet burn tests aimed to better understand the safety issues associated with fires in NPPs. 

These environments include elevated temperatures and humidity and the presence of particulates and Effects Of Smoke On Electronic Equipment corrosive gases. The primary goal was to determine functionality of components when exposed to these environments. Data were also collected to characterize the environments to which those components were exposed. In addition to the burn tests, a small number of thermal failure and long term corrosion tests were included.

The components used in the tests were selected to represent the most easily damaged NPP electrical components, as identified in Ref. [14]. Some of these were powered during the test and subject to active monitoring, while others were unpowered and Effects Of Smoke On Electronic Equipment evaluated for functionality after the test was complete. 

In order to add conservatism and represent a wider variety of designs, Effects Of Smoke On Electronic Equipment some components were placed in non-standard orientations or modified (such as by removal of protective cases) to increase susceptibility to expected causes of failure.Five burn tests were performed, all using unqualified 1 polyvinyl chloride (PVC)-insulated cable as the fuel package. 

Room size and cabinet configuration were varied as was the arrangement of components. The fires lasted between 15 minutes and 40 minutes, Effects Of Smoke On Electronic Equipment and exhibited peak heat release rates between 185 kW and 995 kW. The fires were allowed to burn completely; no suppression was used. Component failures and degradation due to the room-scale burn test were as follows: Switches exhibited slight sensitivity to fire exposure. 

For some, a small number of voltage stresses (at most 15 Vac) were required to resume conduction while others had only slight increases in contact resistance. Fire size and Effects Of Smoke On Electronic Equipment exposure were seen as the most significant factors contributing to degradation. Overall, fire exposure did not impede normal operation of the switches tested. 

Relays (powered and unpowered) showed minor signs of corrosion after testing but did not suffer any loss of functionality. Meters did not suffer any loss of functionality. It is noted that these are generally well sealed, Effects Of Smoke On Electronic Equipment making them less susceptible to infiltration by products of combustion. Pen-based chart recorders suffered mechanical failure due to particulate deposition. 

There was no indication of electrical failure. Electronic counters did not fail during the burn test, Effects Of Smoke On Electronic Equipment despite significant particulate deposition. Some power supply and amplifiers responded adversely to increased temperatures, but were not affected by the products of combustion and functioned properly after the test. 

How To Clean Mold On Shower Grout

Always handle bleach with caution. Bleach can irritate the eyes, nose, throat and skin. Never mix bleach with ammonia – toxic chlorine gas may result. Open a window or door to provide fresh air while disinfecting. Protect skin and eyes from contact with bleach. Test solution on a small area befor  read more..

Dust From Removing Lead Paint

Get Ahead of Lead! Encapsulants: A Teachnique to Control Lead Paint Hazards A complete copy of the Get Ahead of Lead! Encapsulants: A Technique to Control Lead Paint Hazards brochure is available in Adobe Portable Document Format (PDF, 175 KB). Lead-based paint is a health hazard to children and adu  read more..

After Flood Waters Recede

Flood water may be contaminated with sewage or other hazards, so everyone in a flooded area should take precautions to avoid exposure, especially during cleanup. You can be exposed to sewage through hand-to-mouth contact such as eating or drinking, or through cuts, scratches or
wounds, or Water Damage After Flood Waters Recede  read more..

How To Sand And Remove Lead Paint

What is Lead? Lead is a metal that can be found in sources such as paint used in homes built before 1978, soil,water and old painted furniture and toys. Approximately 38 million homes in the United States still contain lead-based paint. Four million of these are home to one or more young childr  read more..

Learn Water Damage Electronic Restoration

All magnetic parts processed to the Class S requirements of MIL-STD-981 are acceptable as level 1 parts. Magnetics processed to Class B requirements of MIL-STD-981 are acceptable as level 2 parts. All level 1 and 2 custom magnetics shall be processed to the Electronic Restoration Learn Water Damage Electronic Restoration applicable requirements of   read more..

How To Kill Mold In A Crawl Space

A properly sealed, moisture-protected, and insulated crawlspace will increase comfort, save on energy costs, improve the durability of the home, and reduce entry of moisture, radon, and other potential irritants or pollutants into the home. Crawl Space Drying How To Kill Mold In A Crawl Space Whichever design is followed, the keys to an  read more..

FEMA Map

If my community is not participating in the CRS, what can I do to have my community join? The decision to join the CRS is a voluntary action of a community's elected officials. As with many community actions, citizens can contact their local elected officials and encourage the community to consider   read more..

How To Clean Up Smoke And Soot From A Fire

How to Clean Up Smoke and Soot from a Fire Smoke and soot can travel and penetrate into other rooms affecting paint, carpet,upholstery, drapes, clothing and any other belongings. Ventilation of the fire scene or debris removal is an effective first step to clean up after fire. Thorough cleaning and   read more..

Guidelines For Fire And Smoke Damage Repair

The National Fire Protection Association (NFPA) has joined forces with theInternational Council on Active Aging(ICAA) to launch this year's Active Aging Week, September 25 to October 1. In celebration of this national health observance, NFPA and ICAA will work with older adults at venues across the   read more..

How To Remove Soot Stains From Stucco

In a final report in the series of non-thermal damage experiments, SNL reports on previously unpublished results including tests of conformal coatings, digital throughput, memory chips, hard disk drives, and electrical properties of fire smoke [19].2.1.7.1 Conformal Coatings In order to gauge the ab  read more..