Smoke Damage >> Fire Smoke Restoration Procedures

Recommendations for the Selection and Use of Protective Clothing and Respirators Against Biological Agents Resulting from a Suspected or Known Terrorism Event The recommendations for personal protective equipment, including respiratory protection and protective clothing, are based upon the anticipated level of exposure risk associated with different response situations, Fire Smoke Restoration Procedures as follows: 

Responders should use a NIOSH-approved, CBRN SCBA in conjunction with a Level A, protective ensemble (use equipment certified to NFPA 1991 when available as a first choice) in responding to a suspected biological incident where any of the following information is unknown or Fire Smoke Restoration Procedures the event is uncontrolled.

The type(s) of airborne agent(s);o The dissemination method(s);o If dissemination via an aerosol-generating device still is occurring, Fire Smoke Restoration Procedures or it has stopped but there is no information on the duration of dissemination or what the exposure concentration might be; Other conditions may present a vapor or splash hazard. 

Responders may use a Level B protective ensemble (use equipment certified to NFPA 1994 Class 2, NFPA 1992, or NFPA 1971 CBRN protective ensembles when available as a first choice) with an exposed or Fire Smoke Restoration Procedures enclosed NIOSH-certified CBRN SCBA if the situation can be defined in which: The suspected biological aerosol is no longer being generated.

Other conditions may present additional hazards, such as a splash hazard. (Note: NFPA 1994 Class 4 does not have a requirement to provide limited protection against liquid or Fire Smoke Restoration Procedures chemical hazards). Responders may use a level C protective ensemble (use equipment certified to NFPA 1994 class 3 or 4 or certified as NFPA 1999 protective ensemble when available as a first choice) with a CBRN full face piece APR or CBRN full face piece powered air-purifying respirator (PAPR) when it can be determined that.

The suspected biological aerosol is no longer being generated; The biological agent and Fire Smoke Restoration Procedures hazard level have been defined;o Dissemination was by a letter or package that can be easily bagged.When a risk assessment has been conducted by qualified safety and health experts, responders may use alternate PPE.

Including non-CBRN level C protective ensembles with a full facepiece particulate respirator (N100 or P100 filters) or PAPR with high efficiency particulate air (HEPA) filters, in conjunction with disposable hooded coveralls, gloves, and Fire Smoke Restoration Procedures foot coverings as appropriate.In certain specialized situations.

Half-mask filtering facepiece respirators in conjunction with reduced levels of dermal protection may be considered, Fire Smoke Restoration Procedures but it should be recognized that this level of PPE may not provide sufficient exposure reduction for many situations. Several parameters must be assessed when making a decision to downgrade the ensemble. 

These include knowledge of the source and extent of contamination, the level of uncertainty in the risk assessment, specific activities to be conducted, investigator experience, Fire Smoke Restoration Procedures contingency/backup plans, length of time in the contaminated area, provision for immunization and post-exposure prophylaxis, etc. 

A decision of this nature should be carefully evaluated and made by industrial hygiene, safety, and medical personnel in conjunction with the incident commander and Fire Smoke Restoration Procedures other appropriate public health authorities. NIOSH recommends against wearing standard firefighter turnout gear into potentially contaminated areas when responding to reports of terrorist activities involving biological agents, provided there are no other hazards that would require turnout gear.

Proper decontamination of protective equipment and Fire Smoke Restoration Procedures clothing will ensure that any particles that might have settled on the outside of protective equipment are removed before taking off gear. Decontamination sequences currently used for hazardous material emergencies should be used as appropriate for the level of protection employed and agent encountered. 

For example, PPE can be decontaminated using soap and water, Fire Smoke Restoration Procedures and 0.5% hypochlorite solution (one part household bleach to 10 parts water) with an appropriate contact time can be used. Note that bleach may damage some types of firefighter turnout gear (one reason why it should not be used for biological agent response actions). 

After taking off gear, Fire Smoke Restoration Procedures response workers should shower using copious quantities of soap and water. Bleach should not be used to decontaminate response workers. Note that all NFPA 1994 ensembles are intended to be disposable after a single exposure use.

This document was prepared by the staff of the National Institute for Occupational Safety and Health (NIOSH) with input from the Fire Smoke Restoration Procedures Occupational Safety and Health Administration (OSHA), Environmental Protection Agency (EPA), and the National Fire Protection Association (NFPA). Les Boord, Director, NIOSH National Personal Protective Technology Laboratory (NPPTL) had overall responsibility for the document.

William Haskell (NIOSH) was the project director.The following Fire Smoke Restoration Procedures contributors are acknowledged: John Decker (NIOSH), Nadia ElAyouby (NIOSH), Debra Flagg (EPA), Robert Koedam (NIOSH), Andrew Levinson(OSHA), Angie Shepherd (NIOSH), Judi Coyne (NIOSH) and Bruce Teele (NFPA).

The members of the InterAgency Board (IAB)—Personal Protective & Operational Equipment (PP&OE) Subgroup are acknowledged for their expertise and guidance inthe development of this document.The Department of Homeland Security (DHS) and Fire Smoke Restoration Procedures the National Institute of Standards and Technology (NIST) are acknowledged for endorsing the need for this document to aid emergency responders.

Vanessa Becks provided editorial support and contributed to the design, graphics, and layout of this document. This Fire Smoke Restoration Procedures guidance document provides local, State and Federal emergency response entities with comparison information on the Occupational Safety and Health Administration/Environmental Protection Agency (OSHA/EPA) 

Protection Levels A, B, and C to Department of Homeland Security (DHS) adopted Personal Protective Equipment (PPE) Fire Smoke Restoration Procedures performance based standards for response to terrorism incidents involving Chemical, Biological, Radiological, and Nuclear (CBRN) hazards Definitions CBRN: An abbreviation for chemicals, biological agents, and radiological particulate hazards.

CBRN terrorism agents: Chemicals, biological agents, and Fire Smoke Restoration Procedures radiological particulates that could be potentially released as an act of terrorism. (See Chemical Terrorism Agents, Biological Terrorism Agents, Radiological Particulate Terrorism Agents).

Chemical terrorism agents: Liquid, solid, gaseous, and vapor chemical warfare agents and Fire Smoke Restoration Procedures industrial chemicals used to inflict lethal or incapacitating casualties as a result of a terrorist attack. Biological terrorism agents: Liquid or particulate agents that can consist of a biologically-derived toxin or pathogen used to inflict lethal or incapacitating causalities as aresult of a terrorist attack.

Thunderstorm Damage

The forces of mother nature, the wind, water, earthquake and even the extremes of temperature  could leave behind debris scattered places, contaminated water, spoiled food, displaced wildlife and overall conditions which, if not treated properly, might lead to major health problems. In t  read more..

How To Get Rid Of Crawl Space Mold

In time,shingles deteriorate from weathering, mechanical wear, and decay. Roof decay due to rain leaks and improper flashing sometimes is troublesome in sheathing and fascia boards. Leaks may also occur near the eaves from the water that backs up under melting snow, Crawl Space Drying How To Get Rid Of Crawl Space Mold unless flashing is  read more..

Floods Are The 1 Natural Disaster In The United S

Flood Facts WARNING: How Flood Smart are YOU? Floods are the #1 natural disaster in the United States. Why Care About Flooding Floods are the most common natural disaster in the United States. From 2003 to 2012, total flood insurance claims averaged more than $3.0 billion per year. In high-risk area  read more..

Radon Gas

What is Radon gas? Radon gas is a gas produced by the radioactive decay of the element radium. Radioactive decay is a natural, spontaneous process in which an atom of one element decays or breaks down to form another element by losing atomic particles (protons, neutrons, or electrons). When solid ra  read more..

Find Out How To Hire Professional Cleaners

The way notice is delivered is very important. A landlord's notice to quit to a tenant must either be delivered personally, or by registered or certified mail. If notice is mailed, a landlord should send the notice to the address of the premises rented by the tenants. If the landlord is not abl  read more..

Water Remediation

When a major natural disaster damages or completely destroys your home or entire neighborhood, everything changes. Whether it’s a massive flood, a stove Flood Damage Water Remediation, hurricane, tornado, earthquake, or winter ice storm, suddenly many things will not work and some things now are not available like   read more..

Waterproof A Basement For Severe Flooding

Remove water trapped within your walls. To check for water,take off the baseboard. Stick an awl or knife into the wall about 2 inches above the floor (just above the 2 X 4 wood sill plate). If water drips out, cut or Flood Damage Waterproof A Basement For Severe Flooding drill a hole large enough to allow water to drain freely. (Use a hand or cordl  read more..

Flood Maps

Why is participation in the NFIP on a community basis rather than on an individual basis? The National Flood Damage Flood Maps Insurance Act of 1968 allows FEMA to make flood maps insurance available only in those areas where the appropriate public body has adopted adequate flood maps management regulations for its fl  read more..

Storm Damage Building Demolition Removal Cost

Local governments manage the debris collection process. They can either perform debris collection work with local employees or use debris collection contractors.If contractors are used, their work and charges should be monitored to ensure the contract costs are eligible for FEMA funding and [ME  read more..

Get Rid Of A Rotten Meat Smell From A Freezer

Although odor from open lots is highly subject to climate changes. A number of things that can be done. Dust from feedlots is a primary concern because dust can absorb and concentrate odor compounds. Dust can also be carried long distances by wind, and tends to Odor Control Get Rid Of A Rotten Meat Smell From A Freezer stay closer to the grou  read more..