Smoke Damage >> Fire Smoke Restoration Procedures

Recommendations for the Selection and Use of Protective Clothing and Respirators Against Biological Agents Resulting from a Suspected or Known Terrorism Event The recommendations for personal protective equipment, including respiratory protection and protective clothing, are based upon the anticipated level of exposure risk associated with different response situations, Fire Smoke Restoration Procedures as follows: 

Responders should use a NIOSH-approved, CBRN SCBA in conjunction with a Level A, protective ensemble (use equipment certified to NFPA 1991 when available as a first choice) in responding to a suspected biological incident where any of the following information is unknown or Fire Smoke Restoration Procedures the event is uncontrolled.

The type(s) of airborne agent(s);o The dissemination method(s);o If dissemination via an aerosol-generating device still is occurring, Fire Smoke Restoration Procedures or it has stopped but there is no information on the duration of dissemination or what the exposure concentration might be; Other conditions may present a vapor or splash hazard. 

Responders may use a Level B protective ensemble (use equipment certified to NFPA 1994 Class 2, NFPA 1992, or NFPA 1971 CBRN protective ensembles when available as a first choice) with an exposed or Fire Smoke Restoration Procedures enclosed NIOSH-certified CBRN SCBA if the situation can be defined in which: The suspected biological aerosol is no longer being generated.

Other conditions may present additional hazards, such as a splash hazard. (Note: NFPA 1994 Class 4 does not have a requirement to provide limited protection against liquid or Fire Smoke Restoration Procedures chemical hazards). Responders may use a level C protective ensemble (use equipment certified to NFPA 1994 class 3 or 4 or certified as NFPA 1999 protective ensemble when available as a first choice) with a CBRN full face piece APR or CBRN full face piece powered air-purifying respirator (PAPR) when it can be determined that.

The suspected biological aerosol is no longer being generated; The biological agent and Fire Smoke Restoration Procedures hazard level have been defined;o Dissemination was by a letter or package that can be easily bagged.When a risk assessment has been conducted by qualified safety and health experts, responders may use alternate PPE.

Including non-CBRN level C protective ensembles with a full facepiece particulate respirator (N100 or P100 filters) or PAPR with high efficiency particulate air (HEPA) filters, in conjunction with disposable hooded coveralls, gloves, and Fire Smoke Restoration Procedures foot coverings as appropriate.In certain specialized situations.

Half-mask filtering facepiece respirators in conjunction with reduced levels of dermal protection may be considered, Fire Smoke Restoration Procedures but it should be recognized that this level of PPE may not provide sufficient exposure reduction for many situations. Several parameters must be assessed when making a decision to downgrade the ensemble. 

These include knowledge of the source and extent of contamination, the level of uncertainty in the risk assessment, specific activities to be conducted, investigator experience, Fire Smoke Restoration Procedures contingency/backup plans, length of time in the contaminated area, provision for immunization and post-exposure prophylaxis, etc. 

A decision of this nature should be carefully evaluated and made by industrial hygiene, safety, and medical personnel in conjunction with the incident commander and Fire Smoke Restoration Procedures other appropriate public health authorities. NIOSH recommends against wearing standard firefighter turnout gear into potentially contaminated areas when responding to reports of terrorist activities involving biological agents, provided there are no other hazards that would require turnout gear.

Proper decontamination of protective equipment and Fire Smoke Restoration Procedures clothing will ensure that any particles that might have settled on the outside of protective equipment are removed before taking off gear. Decontamination sequences currently used for hazardous material emergencies should be used as appropriate for the level of protection employed and agent encountered. 

For example, PPE can be decontaminated using soap and water, Fire Smoke Restoration Procedures and 0.5% hypochlorite solution (one part household bleach to 10 parts water) with an appropriate contact time can be used. Note that bleach may damage some types of firefighter turnout gear (one reason why it should not be used for biological agent response actions). 

After taking off gear, Fire Smoke Restoration Procedures response workers should shower using copious quantities of soap and water. Bleach should not be used to decontaminate response workers. Note that all NFPA 1994 ensembles are intended to be disposable after a single exposure use.

This document was prepared by the staff of the National Institute for Occupational Safety and Health (NIOSH) with input from the Fire Smoke Restoration Procedures Occupational Safety and Health Administration (OSHA), Environmental Protection Agency (EPA), and the National Fire Protection Association (NFPA). Les Boord, Director, NIOSH National Personal Protective Technology Laboratory (NPPTL) had overall responsibility for the document.

William Haskell (NIOSH) was the project director.The following Fire Smoke Restoration Procedures contributors are acknowledged: John Decker (NIOSH), Nadia ElAyouby (NIOSH), Debra Flagg (EPA), Robert Koedam (NIOSH), Andrew Levinson(OSHA), Angie Shepherd (NIOSH), Judi Coyne (NIOSH) and Bruce Teele (NFPA).

The members of the InterAgency Board (IAB)—Personal Protective & Operational Equipment (PP&OE) Subgroup are acknowledged for their expertise and guidance inthe development of this document.The Department of Homeland Security (DHS) and Fire Smoke Restoration Procedures the National Institute of Standards and Technology (NIST) are acknowledged for endorsing the need for this document to aid emergency responders.

Vanessa Becks provided editorial support and contributed to the design, graphics, and layout of this document. This Fire Smoke Restoration Procedures guidance document provides local, State and Federal emergency response entities with comparison information on the Occupational Safety and Health Administration/Environmental Protection Agency (OSHA/EPA) 

Protection Levels A, B, and C to Department of Homeland Security (DHS) adopted Personal Protective Equipment (PPE) Fire Smoke Restoration Procedures performance based standards for response to terrorism incidents involving Chemical, Biological, Radiological, and Nuclear (CBRN) hazards Definitions CBRN: An abbreviation for chemicals, biological agents, and radiological particulate hazards.

CBRN terrorism agents: Chemicals, biological agents, and Fire Smoke Restoration Procedures radiological particulates that could be potentially released as an act of terrorism. (See Chemical Terrorism Agents, Biological Terrorism Agents, Radiological Particulate Terrorism Agents).

Chemical terrorism agents: Liquid, solid, gaseous, and vapor chemical warfare agents and Fire Smoke Restoration Procedures industrial chemicals used to inflict lethal or incapacitating casualties as a result of a terrorist attack. Biological terrorism agents: Liquid or particulate agents that can consist of a biologically-derived toxin or pathogen used to inflict lethal or incapacitating causalities as aresult of a terrorist attack.

Lead Paint Removal Requirements

Where any employee is exposed to lead above the permissible exposure limit for more than 30 days per year, the employer shall implement engineering, work practice, and administrative controls to reduce and maintain employee exposure to lead in accordance with the following implementation schedule ex  read more..

Leaking Water Heater

Use (undamaged) HVAC system and de-humidifiers to aid in reducing relative humidity levels to below 50% if possible to aid in drying of wetted materials Water Damage Leaking Water Heater and to prevent unaffected materials from absorbing moisture in the air. Remove undamaged paper items from affected area if high humi  read more..

How To Restore Water Damaged Pictures

Libraries, archives, museums, and historical societies are responsible not only for collecting, interpreting, and exhibiting significant materials that document history, but also for the long-term preservation, security, and accessibility of these Document restoration How To Restore Water Damaged Pictures materials.

The American Associa  read more..

How Do I Restore Old Documents And Pictures

Although it is neither necessary nor desirable to remove all dirt or discoloration from old papers, surface cleaning sometimes improves the appearance of an artifact. Surface cleaning can also remove substances that might eventually damage paper, Document restoration How Do I Restore Old Documents And Pictures  r that could be transferred to o  read more..

Basement Water Damage

The best way to face any Basement Drying Basement Water Damage problem is to first, do the obvious things, you know the things that are easy and least expensive. Then continue in a rational order doing the next least expensive thing with the most positive result. With a basement moisture problem, the best way to start is alw  read more..

EPA Clean Up Lead Contaminated Soil

For an employee removed due to a final medical determination, when a subsequent final medical determination results in a medical finding, determination, or opinion that the employee no longer has a detected medical condition which places the employee at increased risk of material impairment to healt  read more..

Treatments For Air Duct Mold

There are no laws about mold, but there ARE building codes and public health codes that make sure everyone has safe and healthy housing in Michigan. There are also laws that help protect consumers in Michigan.On the following pages you will find some Mold Remediation Treatments For Air Duct Mold suggestions that may help you addr  read more..

Abatement Asbestos

The following asbestos control program rules, shall apply to all asbestos abatement activities occurring within the City of New York. (b) Every owner of a building where asbestos abatement activity occurs shall be responsible for the performance of the asbestos abatement activities by his/her agent,  read more..

WATER DAMAGE AND MOLD FROM FLOOD RESPONSE

WATER DAMAGE AND MOLD FROM FLOOD RESPONSE FLOOD RESPONSE - WATER DAMAGE AND MOLD HOW DO I PROPERLY CLEAN UP MY HOME IF IT HAS BEEN FLOODED OR HAS WATER DAMAGE? First, Water Damage WATER DAMAGE AND MOLD FROM FLOOD RESPONSE make sure electricity and natural gas or propane tanks are shut down. 

The Centers fo  read more..

Flood Prevention Tips

This is a manual on safe, healthy, green, and affordable rebuilding of water-damaged homes that will: Serve as a workbook for seminars Be distributed to people working on their own homes, volunteers, and other workers as a guide and reference manual Develop work protocols for contractors This manual  read more..