Smoke Damage >> How To Remove Smoke Odor From A Kitchen Fire

Comparison of Fire Performance and Corrosion Work by Chapin et al. [25] evaluated the ability of a variety of standard test methods to evaluate the impact of smoke from local area network (LAN) cables on electrical equipment. Their concern was that the specialized and controlled nature of these tests may prevent them from realistically predicting corrosion and, more importantly, How To Remove Smoke Odor From A Kitchen Fire overall functionality of electronics exposed to smoke. 

They examined correlation among the standard tests and provided a discussion of the sensitivities and possible sources of error.Although the discussion and findings address a larger number of tests, How To Remove Smoke Odor From A Kitchen Fire the authors performed experiments with only three previously existing test methods. ASTM test D5485, International Standards Organization (ISO) test DIS 11907-3 and International Electrotechnical Commission(IEC) test 60754-2 are described in section 3.2 of this report. 

These tests burn complete products, individual conductors, or raw materials (individual components of wire insulation) to classify their tendency to cause corrosion. Both the ASTM and ISO tests subject electrically conductive copper corrosion probes to the smoke produced. The change in conductivity of these copper surfaces is used to estimate the amount of metal lost, How To Remove Smoke Odor From A Kitchen Fire and results are expressed as thickness consumed (ASTM) or percent consumed. 

The IEC test measures pH of gases produced in the burning of a material. Note that the IEC test evaluates individual materials, How To Remove Smoke Odor From A Kitchen Fire and as such, cable coatings must be separated into their jacket and insulation materials for isolated testing. To complement results from the corrosivity standard, other measurements were made to evaluate the fire behavior of the cable samples. 

The chemical compositions of the cable jacket and insulation materials were determined. Each variety of cable was subjected to the ASTM E1354 cone calorimeter. This uses the same combustion apparatus as the ASTM D5485, but produces heat How To Remove Smoke Odor From A Kitchen Fire and smoke release measurements rather than capturing corrosive gasses. 

This information is used in more traditional analysis of flammability How To Remove Smoke Odor From A Kitchen Fire and fire hazards. The smoke release data provide interesting context for the corrosivity measurements by allowing one to evaluate the likelihood and severity of fires involving those materials.The authors report that, in the course of previous work, they have observed that smoke most often causes the failure of digital electronic systems by decreasing surface resistivity. 

In an effort to quantify this behavior relative to the corrosivity tests, How To Remove Smoke Odor From A Kitchen Fire the authors developed a test apparatus to measure changes of surface resistivity of a circuit board exposed to smoke. The tube furnace used in the IEC 60754-2 test was fitted with an exposure chamber into which the products were driven by forced air flow. 

The chamber was used to expose printed circuit boards with an inter digitated comb pattern (similar to those used by SNL for the circuit bridging tests described in Section 2.2). After exposure, How To Remove Smoke Odor From A Kitchen Fire the targets were tested for current flow with an applied 50 V potential. Leakage currents were tested in a controlled humidity chamber over a range of relative humidity from 30 % to 90 %.

Seven commercially available LAN cables were used in these tests. Three of the varieties were rated for plenum use according to Underwriters Laboratories (UL) test 910, indicating a very low fire hazard. The other cables were rated for other use under different UL and IEC tests. All of the plenum rated cables and How To Remove Smoke Odor From A Kitchen Fire some of the non-plenum cables contained large quantities of halogens, which are often cited as a major contributing factor in corrosion caused by smoke [20 -22].

For the purposes of comparison, results have been normalized by the average value from each test method, and How To Remove Smoke Odor From A Kitchen Fire the pH measurements for the IEC 60754-2 have been inverted such that higher values indicate higher acidity. Comparisons of the test results and the correlation between tests are shown in Table 7 and Figure 4 calculated as correlations coefficients from the data in reference [25]. 

The plenum-rated cables (cables A,F,I) are easily differentiated from the non-plenum cables by the leakage current test. Leakage currents caused by the plenum cables were 3 to 7 orders of magnitude lower than the highest performing non-plenum cable (K). It may also be possible to make such distinctions based upon smoke load, How To Remove Smoke Odor From A Kitchen Fire which was higher for non-plenum cables. 

The correlation between smoke load and leakage current is consistent with the premise that leakage currents are the result of circuit bridging by particulates in smoke, as has been found by Chapinet al. [25] and Tanaka [18].This low smoke load produced by plenum cables is not surprising, How To Remove Smoke Odor From A Kitchen Fire as UL 910, which is based on the method developed by Steiner [26], includes criteria for smoke production as well as heat release rate (HRR) and flame spread. 

UL 910 was specifically designed to limit smoke production from cables in a plenum configuration [27]. Products that pass can be expected to produce very small amounts of smoke.The simple calculation of correlation coefficients could suggest that ASTM D5484 is sensitive to smoke load. However, How To Remove Smoke Odor From A Kitchen Fire a more careful examination of material composition would indicate that the presence of PVC is the more important factor. 

The three cable products (cables I,G,B) which caused significant corrosion in this test all used PVC in their jacket and/or insulation, How To Remove Smoke Odor From A Kitchen Fire while the other cables did not. It is interesting to note that cable F contained a low smoke PVC-based compound but produced negligible corrosion in ASTM D5484. The amount of smoke actually produced by this cable was slightly higher than the highly corrosive cable I. 

As both contained similar amounts of chlorine, this suggests that the mechanism used for smoke suppression may also serve to decrease the corrosivity of the combustion products. A larger sample size and How To Remove Smoke Odor From A Kitchen Fire a more detailed treatment of the chemistry involved would be required to develop a full understanding of any role that fire retardant compounds may play in corrosion.

Results of the ISO DIS 11907-3 test are more difficult to explain. The three cables which caused corrosion in the ASTM D5484 (cables I,G,B) did so in this test as well. The smoke suppressed PVC cable (F), How To Remove Smoke Odor From A Kitchen Fire was comparable to one of the ordinary PVC cables (G). Further, the two non halogenated cables caused between 25 % to 50 % as much corrosion as the PVC cables in this test as opposed to less than 10 % in the ASTM test. 

Chapin et al. [24] argue that the corrosion target used in the ISO test may produce inaccurate results, How To Remove Smoke Odor From A Kitchen Fire due to circuit bridging. The target tracks material loss in the form of increased resistivity in a closely packet serpentine copper trace on a circuit board. 

They express concern that connections across the board could decrease effective resistance, resulting in underestimation of total mass loss. The only consistent behavior from the IEC 754-2 pH tests was that halogenated polymers produced low pH, How To Remove Smoke Odor From A Kitchen Fire while non-halogenated polymers did not. There was no strong correlation toeither of the direct corrosion tests.

Leaking Hot Water Heater Bottom

Without a thermal expansion tank, the water pressure in a water heater could build to a very high level and cause leakage at the pressure relief valve (or pop-off valve) located on the water heater. Lime deposits could build up on a leaking pop-off valve and clog this safety device, Water Damage Leaking Hot Water Heater Bottom w  read more..

How To Clean Fire Smoke Damage

Tips on how to handle the fire damage There are companies that are experts in cleaning and/or restoring your personal items.Whether you or your insurer buys this type of fire service, Fire Damage How To Clean Fire Smoke Damage be clear on who will pay for it. 

Be sure to ask for an estimate of cost for t  read more..

Once A Hurricane Or Major Storm Hits

Once a hurricane or major storm hits, it's too late to protect your home and property. But there are things you can do now to limit future wind damage. Some are fairly simple and inexpensive; others will require a contractor. You'll need to consider the characteristics of your home, Wind Damage Once A Hurricane Or Major Storm Hits y  read more..

Drug Laboratory Cleanup

Methamphetamine labs are more than just hazardous and unlawful. They leave a huge mess, and ecological hazard that, according to the law, must be cleaned up. And it takes a special procedure, authorization and inspectors who search the Meth Lab Cleanup Drug Laboratory Cleanup property in full-gear Hazmat suits and bre  read more..

Remove Asbestos Tile In The Home


Minerals consist of atoms that may be arranged in random order or in a regular arrangement. Amorphous materials have atoms in random order while crystalline materials have long range order. Many Asbestos Abatement Remove Asbestos Tile In The Home materials are transparent to light, at least for small particles or  read more..

How To Clean Carpet After A Rain Flood

Foundations, cross bracing and tiedowns are thethree basics of the proper elevation and anchoringof a manufactured home. Each is essential for a safe and Jefrsecure mobile home installation.ey MarkhaMSlab Anchor - feMaThis type of anchor is embedded in aFoundationscement foundations slab. Flood Damage How To Clean Carpet After A Rain Flood
  read more..

Sewage Backup During Flooding

Protecting Your Home From Back Flow The sewage/septic system is designed to remove sewage from a house. If flood water enters the system, the sewage can backup and enter your home. To help prevent this, install a backflow valve in the sewer line. The backflow valve is opened by the flow of sewage ex  read more..

Grants For Flood Damage Tree Removal

By the end of the program, the city had recycled almost 56 percent of all materials collected since the day of the earthquake for less than the cost of disposal. The city demonstrated that when sufficient recycling facility capacity exists, a recycling rate of over 86 percent can be achieved. T  read more..

Water Removal

Did you know the average residential house loses 14% of the water delivered to leaks? In an average home, 22 gallons of water are lost to leakage every day, and the usual suspects are leaking toilets or dripping faucets. This daily leakage amount is about eq  read more..

Certified In Lead Paint Removal

Is Lead Certification Required for the type of work I do? You may need to be certified! There are some situations in which you are legally required to be CDPH Lead-Related Construction (LRC) certified. Even if certification is not required in your situation, CDPH encourages you to become trained and  read more..