Smoke Damage >> Smoke Damage Cleanup Tips

This report presents a review of smoke production measurement, prediction of smoke impact as part of computer-based fire modeling, and measurement and prediction of the impact of smoke through deposition of soot on and  Smoke Damage Cleanup Tips corrosion of electrical equipment. 

Equipment damage from smoke stems primarily from an increased resistance in circuits and connections by corrosive metal loss, and creating conductive paths for current leakage due to smoke deposition. The former Smoke Damage Cleanup Tips may take hours or days after the fire is extinguished to manifest itself in equipment failure, while the latter may occur at failure levels any time soon after initial smoke exposure. 

The literature review on smoke corrosivity testing and damage due to smoke deposition emphasizes (despite extensive research on smoke corrositity) the lack of validated and widely Smoke Damage Cleanup Tips applicable prescriptive or performance-based methods to assure electrical equipment survivability given exposure to fire smoke. 

Corrosion failures following smoke exposure take days or longer to manifest themselves, and Smoke Damage Cleanup Tips corrective actions in the interim time can take place if the exposure is not too severe and intervention is timely. Circuit bridging via current leakage through deposited smoke was identified as an important mechanism of electronic and electrical equipment failure during NPP fires. 

In order to assess the Smoke Damage Cleanup Tips potential for damage due to smoke exposure, relationships between smoke exposure and the failure of real electronic components need to be established. A smoke damage routine developed for a fire model could then assess the near term (during and soon after exposure) damage potential of electronics and electrical components design fire exposures. 

Understanding of absorption of acid gases by smoke and its deposition on surfaces (as a function of temperature, humidity, and smoke reactivity) would be necessary to develop models that could estimate the Smoke Damage Cleanup Tips deposition behavior of smoke. 

EFFECT OF CORROSION PROBE THICKNESS In the longer term, better understanding of combustion, gas-phase, and liquid chemistry could allow Smoke Damage Cleanup Tips estimates of the formation rate of smoke and acid gases as a function of the ventilation, thermal, and fire environments.

In Part 4 [78] of the PFPC study, it is noted that for the cone corrosimeter that the amount of corrosion lost as measured by the 2500 … probe was always higher than that measured by the 45 000 … probe for the same Smoke Damage Cleanup Tips material. Since corrosion is a localized phenomenon, it is possible for different parts of a conductor to have different amounts of material removed. 

Considering the test probe as a series of resisters with different heights (due to local pitting) but the same width and length, the total Smoke Damage Cleanup Tips resistance of the probe can be quite different than that of a probe of average thickness throughout. 

To show the impact of the thickness of the probe and the local variability of the corrosion, consider Figure B-1. It shows a range of Smoke Damage Cleanup Tips probes with thicknesses from 2500 Å to 40 000 Å exposed to the same test environment. 

The "average loss” numbers are from the original data and are determined by calculation from total probe mass loss assuming mass is lost uniformly across the Smoke Damage Cleanup Tips probes. Modeled measures of metal loss (indicated by resistance change) with pitting. 

To estimate the impact of random pitting of a probe, a hypothetical probe was divided into a number of Smoke Damage Cleanup Tips sections with the same width and height, but with a random variation in section height chosen such that the total mass lost was consistent with the average value. 

As can be seen the thicker the probe, the closer the average of the experiments matches the average mass loss calculation. For thinner probes, this results in individual Smoke Damage Cleanup Tips sections particularly thin with higher resistance values. When the whole probe is considered as resistances in series, this results in a higher overall resistance. 

ANALYSIS OF GAS COLLECTION IN A CORROSION TEST APPARATUS To extend the type of analysis of Gandhi [97,98] to consider the withdrawn ASTM E05 test, this Smoke Damage Cleanup Tips section provides an idealized analysis of the gas volume within an arbitrary test chamber. 

The difficulty modeling the ASTM E05 test is the expansion bag, because that leads to a changing volume. Assuming an idealized expansion bag that keeps the pressure in the Smoke Damage Cleanup Tips chamber constant leaves three state variables to describe the chamber.

Mass in chamber, M, the volume of the chamber V and the temperature in the chamber T. Because the chamber captures and holds all the effluent the change in mass can be described by where mb is the rate of the mass of the Smoke Damage Cleanup Tips sample burning and  is the ratio of mass entrainment rate to mass burned rate as a function of height above the sample and the HRR of the sample. 

An energy balance can be used to calculate the temperature where E is the enthalpy in the chamber, c p is the heat capacity of air at constant pressure and Tin is the temperature of the mass entering the Smoke Damage Cleanup Tips chamber from the burning sample. Solving for rate of change of temperature yields. 

Differentiating the volume using the ideal gas law gives where P0 is the constant pressure in the Smoke Damage Cleanup Tips chamber and R R Mave with R being the ideal gas constant and Mave is the average mass of a molecule of air. 

Notice that the rate of change in the volume is directly proportionally to the rate of change in the enthalpy in the chamber so that Calculating P0 in terms of initial conditions, making the Smoke Damage Cleanup Tips substitution in the previous equation and grouping terms results in which interestingly enough is virtually the nondimensionalized differential equation for the volume. 

The three state equations that govern the gas collection system have now been defined. To understand the Smoke Damage Cleanup Tips impact of a gas collection system on the corrosion test, it is important to look at factors that control corrosion, in this case the products produced by burning a test sample. 

Gandhi’s analysis focuses on the mass fraction, Ya, of a species a given that some fraction, y a, of the mass burned becomes a. While this  Smoke Damage Cleanup Tips  assumption ignores details of any reaction chemistry, it is appropriate for a simple analysis of these gas collection systems. 

For the ASTM E05, test, consider what happens if a constant fraction of the mass burned, mb goes to producing a. That produces the following equation for the mass of a in the chamber, which Smoke Damage Cleanup Tips can be written as M·Ys with Ys being the mass fraction of a Solving forgives Since corrosion is based on the concentration, which can be very different from the mass fraction.

Especially if the volume of the chamber changes, the change in concentration is given by Combining and simplifying gives Gandhi non dimensionalizes the Smoke Damage Cleanup Tips equations using the initial conditions to result in the following equations for the ASTM E05 gas collection system

FEMA Flood Maps And Debris Disposal

Management and Disposal of Flood Debris In response to the flood disaster, the Colorado Department of Public Health and Environment ("Department”) is providing guidance and regulatory relief for the Flood Damage FEMA Flood Maps And Debris Disposal management and disposal of damaged or destroyed structures, vegetation debris, vehicles,  read more..

Clean Up Procedures For Mold In A Crawl Space

Crawl spaces and basements can become moisture laden, supporting the growth of mold and the decay of building materials and providing ideal conditions for insect pests and even rodents. Moisture and contaminants can be driven into living spaces by the differences in air pressure between the crawl sp  read more..

Black Mold Removal

Coccidioidomycosis is caused by Coccidioides immitis, a dimorphic fungus that grows as a mold in the soil. The mold forms arthroconidia within the hypha, a type of conidia formation known as enteroarthric development (Figure 1) (4). C. immitis is the only species within the primary pathogenic fungi   read more..

Lead Paint Exposure To Workers In California

Occupational Safety and Health Administration (OSHA) Welding Safety Orders for hot work on painted steel structures require that lead-based paint be stripped back "a sufficient distance from the area to be heated to ensure that the temperature of the unstripped metal will not be appreciably raised."  read more..

Water Damage

Water is by far the single most long-term destructive substance in any indoor environment. It will dissolve or weaken many building materials and supports the growth of microorganisms like mold. Because it can flow, Sewage Cleanup Water Damage has the unique capability to carry with it a wide variety of hazardous p  read more..

Wind Proof Your House

During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds inside the home. In extreme storms, Wind Damage Wind Proof Your House such as Hurricane Andrew, the force of the wind alone can cause weak places in your home to fail.    read more..

Ozone Generators What You Need To Know

Ozone Generators What You Need to Know Many people who want to improve the quality of the air inside of their homes are unknowingly making it worse by using air purifiers that intentionally produce ozone, also called ozone generators.The Connecticut Department of Public Health (CT DPH) recommends th  read more..

Finger Print Dust Cleanup And Hazard Cleanup

Testimony from other lifeguards pointed out other conditions that injure swimmers or other beach patrons and require the assistance of the lifeguard, thereby resulting in occupational exposure to the lifeguard. Patrons suffer lacerations from rocks, shells, broken glass, fish hooks, Crime Scene Cleanup Finger Print Dust Cleanup And Hazard Cleanup o  read more..

Storm Damage Building Demolition Removal Cost

Local governments manage the debris collection process. They can either perform debris collection work with local employees or use debris collection contractors.If contractors are used, their work and charges should be monitored to ensure the contract costs are eligible for FEMA funding and [ME  read more..

How To Dehumidify A Water Damaged Basement

Purified water and feed water samples from cooper tubing condenser test was analyzed in Dehumidification How To Dehumidify A Water Damaged Basement this experiment. The ion removal efficiency is defined as ion concentration difference of the feed and purified water versus feed ion concentration. It present as equation as follow: 
  read more..