Electronic Restoration >> Troubleshoot An Electronic Circuit Board

Optical fiber cable assemblies consist of a combination of two or more of the following parts: optical fiber, cable, connectors, and assemblies. In most cases optical fiber is not used without some type of interconnection. Some of the test methods presented here have been developed at the GSFC Code 562 Technology Validation Assurance (TVA) Laboratory for Photonics Troubleshoot An Electronic Circuit Board and are noted as such. 

The TVA has developed these methods over the past 8 years to address the specific needs of space flight projects at GSFC and to address the failure modes that are common Troubleshoot An Electronic Circuit Board to Commercial-Off-the-Shelf (COTS) optical fiber devices. A references column is provided in Table 4 to provide insight into known failure modes and the test methods used to characterize them. 

All references cited hereare available at http://nepp.nasa.gov/photonics web site. It is important to note Troubleshoot An Electronic Circuit Board that military products cannot in general be assumed to be qualifiedfor space flight. Military specifications are not typically written to accommodate spaceflight requirements. The choice of military qualified fiber components is also verylimited. 

Therefore most of the parts and assemblies used for space flight are COTS.Many of the listed tests are common to commercial and space applications and can beconducted economically only by the manufacturer. In those cases, Troubleshoot An Electronic Circuit Board the manufacturer'scertified results are acceptable. Tests that are critical to determining the suitability ofproduct for space flight are either verified independently or performed in addition tomanufacturers' tests.

Table 3 summarizes the tests to be performed on optical fiber, optical fiber cable, opticalfiber connectors, and optical fiber assemblies that include either optical fiber terminatedto connectors or optical cable terminated by connectors. For each test and part type, a symbol letter is used to designate the entity by which the test is to be conducted: themanufacturer, Troubleshoot An Electronic Circuit Board end user, or both. 

A key is included at the bottom of the table.The Fiber Optic Test Procedures (FOTP-XXX) listed in Table 4 correlate directly to theEIA/TIA 455-XXX series. EIA/TIA 455 has been replaced by FOTP for brevity.Although more tests are done, Troubleshoot An Electronic Circuit Board those specified here are performed typically by the vendor. The tests presented here are required by NASA projects for validation purposes on allgrade levels (i.e., levels 1, 2, and 3). 

There are no distinctions in the validation andqualification of fiber optic components at this time between the grade levels. Testing offiber optics for space flight applications should be determined from the application andreliability requirements of the project. It is the responsibility of the user to specify detailed test conditions and Troubleshoot An Electronic Circuit Board pass/fail criteria for each test. 

These values shall be based on the nearestequivalent military specifications, manufacturer's specification, or the application, Troubleshoot An Electronic Circuit Board whichever is most severe.2/ The group 1A samples shall be subdivided as specified in the table for groups 2 to 6, inclusive. These minimum sample sizes are needed for qualification: Level 1 to 12 fuses Level 2 to 8 fuses Level 3 to 4 fuses3/ 

External visual examination required after testing to verify no evidence of mechanical damage.4/ The power supply shall have Troubleshoot An Electronic Circuit Board an open-circuit voltage not less than the specified voltage rating of the fuse under test.5/ Fuses rated < +125 °C shall be tested to condition A.6/ Materials listed in NASA Reference Publication 1124 that meet TML and CVCM limits are acceptable for use without further testing.7/ 

Not applicable for SMT fuses.8/ Not applicable for SMT fuses utilizing thick or Troubleshoot An Electronic Circuit Board thin film technologies. Hollow SMT fuses constructed with wire-in-air technology shall be subjected to the group 4 inspections. Fuses are specified to interrupt within a maximum of 5 seconds when driven at 200% of their rated current for nominal ratings up to and including 10 amperes. 

A fuse with a nominal rating of 15 amperes is specified to interrupt within a maximum of 10 seconds when driven at 200% of its rated current.The power supply shall be capable of delivering appropriate levels of current to achieve short fusing times.2/ In a space environment, Troubleshoot An Electronic Circuit Board the possible escape of air from inside the fuses reduces the filament cooling mechanism (heat transfer by conduction). 

Thislowers the blow current rating and decreases current capacity with time, making it necessary to derate current ratings on fuses used in space applications.3/ Fuses rated at 1/2 ampere or below are especially affected by loss of air; thus, Troubleshoot An Electronic Circuit Board their derating factors are larger.4/ Current derating factors are based on data from fuses mounted on printed circuit boards and conformally coated. 

Other types of mountings require Troubleshoot An Electronic Circuit Board project office approval. It should be noted that the lifetime of the fuses is controlled by two factors: cold resistance of the fuse and the heat sinkingprovided by the installer. The thermal resistance of the fuse to the thermal ground is very important, as is the case with power transistors and power diodes mounted on circuit boards.5/ 

Recent studies have shown the occurrence of enduring arcs in fuses rated at 125 volts when the applied voltage is greater than 50 volts. Therefore, Troubleshoot An Electronic Circuit Board the voltages on these fuses should be derated to 50 volts or less.6/ Electrical transients produce thermal cycling and mechanical fatigue that could affect the life of the fuse. 

For each application, Troubleshoot An Electronic Circuit Board the capability of the fuse to withstand the expected pulse conditions should be established by considering the pulse cycle withstanding capability for nominal I2t (energy letthrough the fuse) specified by the manufacturer. Any test that has been performed during screening on the samples selected for qualification tests need not be repeated.2/ 

Generic data may be used in lieu of testing as long as the data meets the following requirements:i) It is obtained on parts built to S-311-P-079 specifications using the same materials and Troubleshoot An Electronic Circuit Board similar construction and design, andbuilt in the same facility as the flight parts.ii) The data is less than 2 years old relative to the lot date code of the flight parts.3/ Samples for Groups 2, 3, and 4 should be selected from parts that have passed Group 1 tests.

Certifications For Asbestos Pipe Removal

Analytical Procedure: A portion of the sample filter is cleared and prepared for asbestos fiber counting by Phase Contrast Microscopy (PCM) at 400X. Commercial manufacturers and products mentioned in this method are for descriptive use only and do not constitute endorsements by USDOL-OSHA. Similar p  read more..

What To Do If Hardwood Floors Have Flood Damage

If your house is being flooded by lowing waters entering through windows, doors or other openings, you can temporarily seal those openings to keep the water out.Make or purchase metal or wooden shields to it the openings. Secure the shields to the openings with bolts or Flood Damage What To Do If Hardwood Floors Have Flood Damage slide them into special   read more..

Hurricane Flooding Facts

Do I need the Hepatitis A vaccine?There is no indication for the Hepatitis A vaccine given the anticipated conditions in the region Water Damage Hurricane Flooding Facts and low probability of exposure. No transmission from contaminated water has been identified in the U.S. since the 1980's. 

<  read more..

Tree Removal From Flood Damage

Monitoring costs in operations we reviewed ranged from 20% to 33% of the total cost of debris operations. Other reviews have reported monitoring costs of as FEMA's Oversight and Management of Debris Removal Operations Page 23 much as 50% of total debris costs. Having enough FEMA, state, or local off  read more..

How To Remove Radon From A Basement

Category I Course Work As stated above, participants in the Residential Mitigation Service Provider component of the RPP must earn a minimum of eight (8) of the required sixteen (16) hours of continuing education every two years through approved Category I course work. Those with dual listings are r  read more..

Get The Smell Of Raw Sewage Out Of The House

The overall performance of a lift station depends on the performance of the pumps. All pumps have four common performance characteristics: capacity,head, power, and overall efficiency. Capacity (flowrate) is the quantity of liquid pumped per unit of time, typically measured as gallons per minute(gpm  read more..

Water Removal 2

Clean mold off hard surfaces with water and detergent, and dry completely. Absorbent materials such as ceiling tiles, that are moldy, may need to be replaced. Prevent Water Damage Water Removal 2 condensation: Reduce the potential for condensation on cold surfaces (i.e., windows, piping, exterior walls, roof, or flo  read more..

Storm Damage

Applying for a reimbursement grant from FEMA can be a time-consuming but worthwhile process. Like many government agencies there are endless types of forms and finding the correct one may be difficult. Like any type of reimbursement there are deadlines where the forms would have to be submitt  read more..

Signs Of Animal Damage And Useful Animal Informati

Can deer with EHD (Epizootic Hemorrhagic Disease) be harmful to humans? The most important thing for hunters, landowners, and the public to know is that this is a regular and natural event that routinely afflicts white-tailed deer and that it is not transmissible to humans or Animal Damage Signs Of Animal Damage And Useful Animal Informati any othe  read more..

Debris Removal

Did you know that nearly 3,500 children are injured or lose their life due to fires annually?  Some of these fires are a result of children playing with matches, lighters or candles. Without a doubt we need to educate our children about the dangers of Fire Damage Debris Removal. But we must be careful not to frig  read more..