Emergency Board up >> How To Make Children Aware Of Disaster Management

    Cut plywood to fit over the window and dooropenings, flush with outside of the molding.Note: For buildings with metal door andwindow frames the alternative is tocut the plywood and 2x4s to fit theinside of the door frame buffed upagainst the band molding.2. Cut the 2x4s to fit the horizontal dimensionof the plywood.
    You will need two 2x4exterior and two interior braces for eachwindow and three sets for each door.For buildings with metal doors and windowframes the 2x4s for the outside will be cut tothe dimensions of the plywood, fitting insidethe door frame, against the band molding. Forthe inside the 2x4s will be cut to the outsidedimension of the door or window frame.3.
    Pre drill 3/8th inch holes in the plywood andthe braces.4. The holes will be placed approximately 1/3of the length of the brace from each outsideedge of the door and window jam.5. The two window braces will be placed 1/3of the distance from the top and the bottomof the window.6.The three door braces will be placed; onein the center of the doorway, and one halfthe distance from the center to the top andto the bottom of the doorway.
    Place the plywood over the exterior openingand nail to the frame.For metal frames place the plywood andbraces inside the frame against the bandmolding.8. Place the 2x4 braces over the interior andexterior of the door or window.9. Place the large washer over the carriage boltand place the bolt through the holes.10.Place washer and nut inside and tightensecurely.
    Torque the nut so that it slightlycompresses the interior 2x4. After all entrances are secured,the interior worker should exitthe building, using a ladder,through a window, if such exists,at least 10 feet above the ground.Nail or screw a plywood sheetover the worker's exit. Patrol thebuilding periodically to checkthe security. MATERIALS NEEDED
    A . 1/2" plywood, grade CDX and 2" x 4" by 8'construction grade lumber.B . 3/8" by 12" carriage bolts (rounded head onweather side).C. 3/8" construction grade nuts.D . Flat washers with an inside diameter largeenough to bypass the wrench neck insidethe carriage bolt head so no lift edge isavailable beneath an installed carriagebolt head.E. 1/2" diameter flat washers for installationbeneath the nut inside the building.
    F . 1-5/8" (6d) galvanized or stainless steel ringshank nails or comparable deck nails.WINDOWSWindows raisedand lowered tocenter of the frameView from inside bldg.Note: Outside view of window is same as viewfrom outside door except with two 2x4braces instead of three.
    DOORSNut & WasherOPTIONALscrew anadditional 2x4to the thresholdbutting againstthe inside ofthe plywoodView from inside bldg.Bolt's to inside 2x4View from outside bldg2x4's cut tofit insidePlywoodcut to sizeand 2x4's cutto fit againstinside doorband moldingAlternate Method:cut plywoodand 2x4s tocover the outsideof the door frame.
    3) The car and counterweight shall be located to the lowest landing.4) All ropes removed.5) Main line fuses removed.6) Service switch opened and the cabinet sealed with a padlock.7) Where landing doors are in use, the doors shall be bolted securely to the closedposition from the hoistway side.
    8) When landing gates are in place, the landing openings shall be totally enclosedand strongly reinforced.EXCEPTION: The lowest landing door shall be locked from the landingside.Fire Alarm and Fire Protection Systems1. All fire alarm and fire protection systems must remain active until specificinstructions are provided by local Fire Department.
    2. The shutting down of fire sprinklers requires a permit signed by the local firedepartment. The Department or Agency will obtain this permit. Shutting down fireprotection systems without a permit is in violation of MGL Chapter 148, Section 27Aand is considered a criminal offense.
    3. In the event that the local Fire Department will not allow the shut down of thesprinkler system:Note to the Fire Department that there will be no heat in the building as it is being"cold secured", therefore any active wet sprinkler system would freeze.Drain interior sprinkler system to prevent freezing, install an exterior PIV betweenthe street shut off valve and the exterior face of the building.
    Leave water mainactive to PIV. In the event of a fire, the local fire Department can open the PIV andflood the interior sprinkler system.Convert existing system to some form of dry pressure activated system.Discuss and agree with the local Fire Department any and all alternative methods ofachieving fire protection.
    4. Water mains supplying the fire hydrants, PIV and other fire protection systems shallnot be turned off.5. Department or Agency personnel will meet with the local fire department and willprovide them with site-specific fire protection requirements.6. Do not remove fire hoses, fire detectors or fire extinguishers from the buildings.
    Power PlantThe power plant shall be shut down in a condition of long-term storage (one year) with the intentionof restart with minimum deterioration. The "dry lay-up" method shall be used in which all systemsare drained. The following are the minimum steps required:1. Power down in accordance with standard operating procedures.
    Check the boilermanufacturer's operating manual for specific instructions.2. Oil delivery should be scheduled prior to shut down, so that a minimum of oil is left ineach tank. The Department should arrange to have all residual oil pumped out by theirsupplier as soon after shut down as possible.3. Allow boiler water to return to room temperature and drain the boiler water.
    4. Clean fire and watersides of boilers to remove scale and soot.5. Install drying agent in both water and fire side of units. Leave manhole access coverson the boiler open.

How To Stop Hoarding Things

Hoarding is the acquisition of, and failure to discard a large number of possessions in a residence which appear to be useless or of limited value. Living spaces, furniture, appliances and utilities are sufficiently cluttered as to prevent their intended use, which could pose a significant risk to h  read more..

Water Heater Leaking From The Bottom

After floods, excess moisture and standing water contribute to the growth of mold in homes and other buildings. When returning to a home that has been flooded, be aware that mold may be present and may be a health risk for your family. People at Greatest Risk from Mold People with asthma, allergies   read more..

How To Stop Sewage Backup In Toilets

Sewage Back-Ups:Information for Residents Severe rainstorms, floods, and even spring thaws can put a strain on sanitary sewers and septic systems. Large volumes of storm water and ground water entering sewage systems can inundate them, causing back-ups into basements and Sewage Cleanup How To Stop Sewage Backup In Toilets on to private  read more..

Worker Safety During Fire Cleanup

Worker Safety During Fire Cleanup FACT SHEET On This Page Electrical Hazards Carbon Monoxide Poisoning Musculoskeletal Hazards Heavy Equipment Extreme Heat and Cold Unstable Structures Hazardous Materials Fire Working in Confined Spaces Worker Fatigue Respiratory Hazards First Aid Protective Equipme  read more..

How To Clean Up After Sewage Backups

Occasionally a blockage in a sewer line will result in a backup of sanitary sewage into a private home. If you experience a backup, immediately contact your city's public works department. The following information will answer the basic questions about what to do if you experience a backup and   read more..

How To Strip Lead Paint Off Wood

Methods for Removing Lead Paint Mechanical Methods: Mechanical (abrasive) methods of treating lead-painted surface shave two major drawbacks. They produce high levels of dangerous residue, and they have potential to damage the underlying substrate.SCRAPING: Traditional scraping with hand tools is a   read more..

Tornado Damage

During a typhoon, houses might get wind damage or destroyed by high wind damage and high undulations. Debris could smash windows and doors, permitting high wind damage inside the house. In tremendous storms, such as Typhoon Andrew, the force of the Wind Damage Tornado Damage alone could cause weak spots in your ho  read more..

Servpro

Name of Product: Notus air movers/blowers Units: About 24,000 Manufacturer: EDIC, of Los Angeles, Calif. Hazard: The air mover/blower's internal electrical capacitor can fail and overheat, posing a fire hazard. Incidents/Injuries: Fire Damage Servpro has received four reports of overheating incidents with the reca  read more..

Contamination From Lead Paint

Checking Your Home for Lead You can get your home tested for lead in several different ways: A lead-based paint inspection tells you if your home has lead  based paint and where it is located. It won't tell you whether your home currently has lead hazards. A trained and certified testing profes  read more..

Basement Flood Cleanup

When returning to your home after a hurricane or flood, be aware that flood water may contain sewage. Protect yourself and your family by following these steps:Inside the Home Keep children and pets out of the affected area until cleanup has been completed. Wear rubber boots, rubber gloves, and Water Damage Basement Flood Cleanup  read more..