Emergency Board up >> How To Make Children Aware Of Disaster Management

    Cut plywood to fit over the window and dooropenings, flush with outside of the molding.Note: For buildings with metal door andwindow frames the alternative is tocut the plywood and 2x4s to fit theinside of the door frame buffed upagainst the band molding.2. Cut the 2x4s to fit the horizontal dimensionof the plywood.
    You will need two 2x4exterior and two interior braces for eachwindow and three sets for each door.For buildings with metal doors and windowframes the 2x4s for the outside will be cut tothe dimensions of the plywood, fitting insidethe door frame, against the band molding. Forthe inside the 2x4s will be cut to the outsidedimension of the door or window frame.3.
    Pre drill 3/8th inch holes in the plywood andthe braces.4. The holes will be placed approximately 1/3of the length of the brace from each outsideedge of the door and window jam.5. The two window braces will be placed 1/3of the distance from the top and the bottomof the window.6.The three door braces will be placed; onein the center of the doorway, and one halfthe distance from the center to the top andto the bottom of the doorway.
    Place the plywood over the exterior openingand nail to the frame.For metal frames place the plywood andbraces inside the frame against the bandmolding.8. Place the 2x4 braces over the interior andexterior of the door or window.9. Place the large washer over the carriage boltand place the bolt through the holes.10.Place washer and nut inside and tightensecurely.
    Torque the nut so that it slightlycompresses the interior 2x4. After all entrances are secured,the interior worker should exitthe building, using a ladder,through a window, if such exists,at least 10 feet above the ground.Nail or screw a plywood sheetover the worker's exit. Patrol thebuilding periodically to checkthe security. MATERIALS NEEDED
    A . 1/2" plywood, grade CDX and 2" x 4" by 8'construction grade lumber.B . 3/8" by 12" carriage bolts (rounded head onweather side).C. 3/8" construction grade nuts.D . Flat washers with an inside diameter largeenough to bypass the wrench neck insidethe carriage bolt head so no lift edge isavailable beneath an installed carriagebolt head.E. 1/2" diameter flat washers for installationbeneath the nut inside the building.
    F . 1-5/8" (6d) galvanized or stainless steel ringshank nails or comparable deck nails.WINDOWSWindows raisedand lowered tocenter of the frameView from inside bldg.Note: Outside view of window is same as viewfrom outside door except with two 2x4braces instead of three.
    DOORSNut & WasherOPTIONALscrew anadditional 2x4to the thresholdbutting againstthe inside ofthe plywoodView from inside bldg.Bolt's to inside 2x4View from outside bldg2x4's cut tofit insidePlywoodcut to sizeand 2x4's cutto fit againstinside doorband moldingAlternate Method:cut plywoodand 2x4s tocover the outsideof the door frame.
    3) The car and counterweight shall be located to the lowest landing.4) All ropes removed.5) Main line fuses removed.6) Service switch opened and the cabinet sealed with a padlock.7) Where landing doors are in use, the doors shall be bolted securely to the closedposition from the hoistway side.
    8) When landing gates are in place, the landing openings shall be totally enclosedand strongly reinforced.EXCEPTION: The lowest landing door shall be locked from the landingside.Fire Alarm and Fire Protection Systems1. All fire alarm and fire protection systems must remain active until specificinstructions are provided by local Fire Department.
    2. The shutting down of fire sprinklers requires a permit signed by the local firedepartment. The Department or Agency will obtain this permit. Shutting down fireprotection systems without a permit is in violation of MGL Chapter 148, Section 27Aand is considered a criminal offense.
    3. In the event that the local Fire Department will not allow the shut down of thesprinkler system:Note to the Fire Department that there will be no heat in the building as it is being"cold secured", therefore any active wet sprinkler system would freeze.Drain interior sprinkler system to prevent freezing, install an exterior PIV betweenthe street shut off valve and the exterior face of the building.
    Leave water mainactive to PIV. In the event of a fire, the local fire Department can open the PIV andflood the interior sprinkler system.Convert existing system to some form of dry pressure activated system.Discuss and agree with the local Fire Department any and all alternative methods ofachieving fire protection.
    4. Water mains supplying the fire hydrants, PIV and other fire protection systems shallnot be turned off.5. Department or Agency personnel will meet with the local fire department and willprovide them with site-specific fire protection requirements.6. Do not remove fire hoses, fire detectors or fire extinguishers from the buildings.
    Power PlantThe power plant shall be shut down in a condition of long-term storage (one year) with the intentionof restart with minimum deterioration. The "dry lay-up" method shall be used in which all systemsare drained. The following are the minimum steps required:1. Power down in accordance with standard operating procedures.
    Check the boilermanufacturer's operating manual for specific instructions.2. Oil delivery should be scheduled prior to shut down, so that a minimum of oil is left ineach tank. The Department should arrange to have all residual oil pumped out by theirsupplier as soon after shut down as possible.3. Allow boiler water to return to room temperature and drain the boiler water.
    4. Clean fire and watersides of boilers to remove scale and soot.5. Install drying agent in both water and fire side of units. Leave manhole access coverson the boiler open.

How To Clean Sewer Overflows In Your House

Do you have a chronic sanitary sewer backup problem? The City of Decatur has a program to help stop sewer backups in your home. The Sewage Cleanup How To Clean Sewer Overflows In Your House program is available to homeowners within the City of Decatur city limits. This brochure gives overview of the "Sanitary Sewer Backup Prevention Program"  read more..

Black Mold And Asthma Attacks

Nocturnal asthma refers to asthma symptoms that seem worse in the middle of the night, typically between 2AM and 4AM. Interestingly, nocturnal asthma can affect someone with any type of asthma. Factors that can cause your asthma symptoms to worsen at night may include sinus infections or postna  read more..

Tenant Left Unwanted Junk

The Fairfax County Zoning Ordinance says that no more than four unrelated people may live in a house. Following are other zoning rules that govern how many people can live in a house: One family, which may consist of one person or two or more persons related by blood or marriage with any number of   read more..

Vermiculite Insulation

Protect Your Family from Asbestos Abatement Vermiculite Insulation Asbestos-Contaminated Vermiculite insulation Insulation This page provides important information on how to protect yourself and your family i  read more..

Asbestos Siding Removal

Asbestos siding was installed on thousands of homes in the early to the middle 1900s. This siding looked almost like concrete, some of it had texture that had lines running vertically, the bottom of the tile looked kind of wavy. Some people call it asbestic, which is just another form made of   read more..

How To Clean Sewer Discharge In Basements

CLEANING UP THE MESS.....After the Flood or Sewage Backup If you have a sewer backup in your house, Sewage Cleanup How To Clean Sewer Discharge In Basements you MUST clean properly to prevent you and your family from becoming sick or injured. Do Not bring children into the flooded area during clean-up! The following are suggestions on how to cleanup   read more..

What Are Some Signs Of A Meth Lab

In a Tier 1 decontamination response, adult clothing and small washable fabricitems such as curtains, rugs and linens can be machine-washed twice with hot water anddetergent. After washing contaminated items, Meth Lab Cleanup What Are Some Signs Of A Meth Lab the washer shall be run once empty of clothing.
 
  read more..

How To Prevent Basement Condensation

Perlite is a mined volcanic glass material. When heated, water trapped in the glass matrix vaporizes. As it does so, it expands the heat-softened glass Basement Drying How To Prevent Basement Condensation material, creating a particle with a rough outer surface and an interior composed of closed-cell glass bubbles. He recommends use of this   read more..

Best Way To Remove Hurricane Damage Debris

FEMA concurs with this recommendation. FEMA encourages PA applicants to use force account labor to conduct their debris removal operations. FEMA currently reimburses PA applicants for force account overtime hours. FEMA also reimburses applicants for the use of Debris Removal Best Way To Remove Hurricane Damage Debris equipment. Current FEMA   read more..

How To Get Rid Of Sewer Smells

In general, the TRS concentration was high from the noon to the evening, with several intermittent high peaks (Figure 4(D)). In fact, the shops and jewelers in the district were open late in the morning at 9:00 to 11:00; so low TRS emission could be observed in the early morning. After the shops wer  read more..