Emergency Board up >> Hurricane Safety Procedures

The contractor must submit drawings to DCAM through the Department or Agency for approval of any windows or openings to be sealed by any method other than that shown in sketches listed in number 1 above.9. For windows over 48 inches wide or 96 inches in height, the contractor must submit drawings to DCAM through the Department or Agency for approval showing method of framing the plywood enclosure and Hurricane Safety Procedures the method of securing to the building. 

Such method shall comply with the intent of attached sketches. Doors 1. An emergency access/egress door shall be provided at the front and rear of each building, or Hurricane Safety Procedures as otherwise determined by the local fire and public safety officials inconjunction with DCAM. Each emergency access/egress door shall be installed as perattached sketch #7. 

All locks shall be keyed alike with three (3) keys. Keys shall beturned over to the local fire department one (1) and DCAM Office of Surplus Propertytwo (2).2. Emergency access/egress doors are to be painted fire engine red. The building number Hurricane Safety Procedures and location of the door are to be painted in red on a yellow background as perattached sketch #7.3. 

Doors designated emergency access/egress doors shall be shown on the plot plan, and Hurricane Safety Procedures a copy of this plot plan shall be given to the local fire department.4. Note: Emergency access/egress doors must open without binding or sticking.Contractor shall replace any hinges or hardware on these doors so they shall operateproperly. 

Any doors designated as access/egress doors which cannot be repaired shall be replaced.5. All other exterior doors up Hurricane Safety Procedures to a height (bottom of threshold) less than 12’ above gradeshall be permanently sealed with 3/4” exterior grade plywood, type CDX per below. A. Remove and dispose of all screen doors.B. Remove doorknob.

C. Existing mortised lock to remain and be secured in the locked position.D. Cut plywood to overlap door, hinges and Hurricane Safety Procedures doorjamb.E. Secure plywood with minimum 2" long galvanized screwnails 6" on center aroundthe perimeter of door into the doorjamb and through the center of the door bothhorizontally and vertically.

F. If doorframe is rotted, contractor shall provide new nailing strip (2 x 4s) to replaceframe.6. Plywood shall be stained on all edges and both faces with a combination exteriorgrade stain and Hurricane Safety Procedures sealer. For doors to be permanently sealed, color of stain shall matchthe building exterior. Fire Escapes Remove from all buildings, fire escapes and ladders attached to buildings up to aheight of 12 feet above grade.2. 

Doors and windows above the first floor level shall also be sealed per these procedures if they are accessible from outside stairs and landings or Hurricane Safety Procedures if required by Department of Public Safety or the local Fire Department. Building Interior General Notes For:Electricity/Water/Telephone/Gas:The intent of cold securing a building is to completely discontinue electrical power, water service, telephone service and gas service to the building by terminating the services at the street.

Make arrangements with DCAM to pay all utility bills. All utility bills must be paidin full prior to acceptance of property by DCAM.If unable to comply with this policy based on conditions beyond the control of theDepartment or Agency (due to requirements of the Department of Public Safety orthe local Fire Department), Hurricane Safety Procedures the Department or Agency must notify DCAM and attempt to discontinue, internally, as many service as possible as per below.1. 

Turn off the water supply to the building. Close the shut-off valve located directly outside of the building. If the outside valve does not shut off the water flow completely, Hurricane Safety Procedures install new valve. If no exterior valve exists and electrical power is toremain on, close internal shut off valve, install heat tracing and insulation around thewater main from the inside of the building wall up to and encase the inside shut-offvalve. 

If no electrical power exists, a new exterior shut off valve must be installed.2. Drain all sanitary plumbing systems and pump out by a suction pump or compressedair, Hurricane Safety Procedures all residual water in each plumbing fixture trap. Back fill all traps, includingclean-out traps, with anti-freeze.3. Drain all hot water heaters, water storage tanks and other tanks containing water. 

Donot back fill with anti-freeze any tanks or Hurricane Safety Procedures lines used for domestic water use.4. Turn off the electric service to all electric motors operating HVAC equipment. Drainall HVAC systems of water. Remove all window units and re-seal windows.5. Turn off the electric service to all electric motors operating compressor pumps, etc.

Note: If required, and only after approval by DCAM, do not turn off electric serviceto sump pumps used to keep tunnels, cellars, etc. from flooding. Deactivate electrical systems in the building including lighting, Hurricane Safety Procedures power and electricmotor systems. This can be done by shutting down the main building power circuitand disconnection from the street. 

Power systems shall be left in a condition thatthey can easily be restarted.7. Notify local Telephone Company to disconnect phone service. 8. Turn off the main gas shut-off inside the building and the individual shut-offs to each appliance. For safety reasons, Hurricane Safety Procedures the local Gas Company must turn off the gas at thestreet.9. 

Remove all trash and Hurricane Safety Procedures debris and all personal property which has been declared worthless. Follow Department of Procurement and General Services Regulations.10. Properly archive all pertinent records. Notify the Secretary of the Commonwealth,Archives Division, 220 Morrissey Boulevard, Boston, MA 02125, telephone number(617) 727-2816. 

Do not leave any records stored within building.11. Remove all locksets and latching devices from interior doors, Hurricane Safety Procedures which may hinderaccess/egress. This is a Fire Department requirement.Elevator Shutdown 1. Provide for elevator shutdown in accordance with 524 CMR 11.00 Elevators Placed Out of Service.Elevators Placed Out of Service

All elevators and dumbwaiters placed out of active service for a period exceeding one year shall comply with the following:1) The owner or his agent shall notify the authorized elevator inspector in writing, Hurricane Safety Procedures giving the date when the elevator or dumbwaiter will be placed out of service.2) If the out of service period exceeds one year from the date of notice received,the complete installation shall be subject to a complete inspection and safetytest before again being placed in service.

EPA Radon

RADON MITIGATION STANDARDS 1.0 BACKGROUND The 1988 Indoor Radon Abatement Act (IRAA) required the Environmental Protection Agency (EPA) to develop a voluntary program to evaluate and provide information on contractors who offer radon control services to homeowners. The Radon Contractor Proficiency (  read more..

OSHA Requirements For Meth Lab Cleanup

The decontamination standard set by Kentucky’s meth cleanup law is 0.1 micrograms of meth per100 square centimeters (0.1 ug/100 cm2) of surface materials. See Section V. InteriorDecontamination Procedures for the decontamination procedures for each tiered cleanup response.When states originall  read more..

Mold Remediation Protocol

If the remediation job disturbs mold and mold spores become airborne, then the risk of respiratory exposure goes up. Actions that are likely to stir up mold include: breakup of moldy porous materials such as wallboard; invasive procedures used to examine or remediate mold growth in a wall cavity; ac  read more..

How To Choose A Professional Dehumidifier

Flat-plate heat exchangers consist of a series of flat Dehumidification How To Choose A Professional Dehumidifier or nearly flat heat exchange surfaces arranged in such a way that alternating air passages are connected to one air stream with remaining passages connected to the second air stream. the recuperative application of the air-to-air   read more..

How To Sand And Remove Lead Paint

What is Lead? Lead is a metal that can be found in sources such as paint used in homes built before 1978, soil,water and old painted furniture and toys. Approximately 38 million homes in the United States still contain lead-based paint. Four million of these are home to one or more young childr  read more..

Decontamination Specialists Clean Up In Ohio

The following descriptions outline the occupational exposures that are common to Public Safety Officers and Emergency Medical Services personnel. Emergency Medical Services: Individuals who render emergency medical services are clearly at risk for blood  exposure incidents.  Crime Scene Cleanup Decontamination Specialists Clean Up In Ohio Pre-  read more..

What Are Molds?

What are molds? Molds are microscopic organisms that live on plant or animal matter. They aid in the break down of dead material and recycle nutrients in the environment. Present virtually everywhere, they can be found growing on organic material such as soil, foods, and plant matter. In order to re  read more..

Use A Crawlspace Dehumidifier In Your Crawlspace

Select an appropriate winter vacation temperature setting: 37. When leaving your home unoccupied during periods of both mild and severe winter temperatures, finding the right temperature setting can be a challenge. Crawl Space Drying Use A Crawlspace Dehumidifier In Your Crawlspace. It requires balancing the need to minimize the amount of heat added t  read more..

Mold Remediation

The following are the minimum steps that shall be applied to all Document restoration Mold Remediation projects, and for smaller, minor restorations that could be in non-sensitive, unoccupied areas such as the flooded regions that have involved personal, single dwelling homes. This information will help you understand how a p  read more..

How To Care For Antique Paper

Prepare a work surface by covering a sheet of clean blotting paper with a sheet of nonwoven polyester such as Reemay or Hollytex to prevent the documents being repaired from sticking to the paper because of stray or Document restoration How To Care For Antique Paper extruded paste. 

Begin by mending th  read more..