Dehumidification >> Structural Drying

Convalescent heat substitute is a worldwide skill appropriate to vapor-density, direct-growth, and cooled-water air-handling-unit (AHU) coils; heat-driven desiccant Structural Drying equipment; dehumidifiers; supermarket, ice-rink, and natatorium air-conditioning and dehumidification systems; and bundled 100-percent-outside-air conditioners. This portion talks about five kinds of restorative sensible-heat trials overcooling while still meeting the dehumidification requirements of a conditioned area.

  1. The energy features of this skill are clarified in great detail. The general reason for this is that many Structural Drying proprietors and  creators are under the wrong assumption that there are no consequences that go along with the use of hot-gas or condensed-water reheat. This is not to say that one must always use some kind of restorative heat substitute in partiality to hot-gas or condensed-water reheat. It merely is to say that proprietors and creators must be aware that there is a far more energy-efficient way to achieve reheat while also lowering the required cooling amount. Also spoken in this portion are the four consequences related with the usual “new-energy” reheat and a Structural Drying skill that is used to evade one of those consequences: reheat using hot refrigerant gas.
  2. Restorative-dehumidification development are good answers for 100-percent-outdoor-air cooling units. Each of the first four development involves one heat-transferal expedient is situated upstream from the chief chilling coil and one heat-transfer expedient located downstream from the chief cooling coil. The upstream  expedient precools air as it enters the chief cooling coil, while the downstream  expedient reheats the air by the same change as it leaves the chief cooling coil. Other than a small Structural Drying upsurge in fan energy to overwhelm the added air resistance of the reheating sections and a fractional-hp  drive for the coil-loop enhancement, no external power is used.
  3.  If the heat exchange expedients are active for only a small time of the annual working hours, try the bypass dampers to minimize the annual energy impact. The first five development could be useful to any kind of primary cooling coil: chilled water, chilled glycol, or refrigerant. If the primary coil is of the refrigerant type, then the of the cooling system should be confirmed at mild- and cool-weather entering-air conditions to make sure that the  cooling system will function without compressor cycling or liquid slugging and with proper oil return. If the suction temperatures above 30 F are essential to pre-frost or ice buildup on the chief cooling coil.
  4. The performance of 100-percent outside-air restorative-Structural Drying development may vary from a maximum temperature differential at peak cooling to no temperature difference at an outside temperature of about 50 F. This performance generally is allowed because the dormant load of the outdoor air goes down with the outside temperature. Functions should be analyzed to decide if another reheat from hot refrigerant gas, the electric heating coils, thermal heating coils, or in-space heat sources is required to chieftain acceptable area conditions. Extra reheat coils, if needed, should be positioned downstream from the restorative-dehumidification reheat coil. Heating, restorative-reheat, and conservative reheat coils should be divided from the chief cooling coil to allow the Structural Drying condensed moisture to drain.

Occupational Exposure To Lead

This section applies to all occupational exposure to lead, except as provided in paragraph (a)(2). (2) This section does not apply to the construction industry or to agricultural operations. (b) Definitions. Action Level. Employee exposure, without regard to the use of respirators, to airborne lead   read more..

Fire Damage

When your tenants have been careless and they may have caused a Tenant Move Out Cleanup Fire Damage, who do you turn to for help? Expert fire and water damage restoration services are an outstanding resource of Tenant Move Out Cleanup Fire Damage and restoration information of your personal possessions. Local fire restoration businesses offering this ki  read more..

How To Do Radon Testing

REGIONAL RADON TRAINING CENTERS (RRTCS)The EPA supports four Regional Radon Training Centers. Each RRTC is either an individual university or a consortium of universities that offer a variety of radon-related training courses. The EPA strongly encourages participants to be trained in all aspects of   read more..

Fire Damage Electronic Restoration Classes

Some Micro-miniature and Nano-miniature type connectors have the option of pre-terminated cross linked ETFE (TefzelTM) insulated wire pigtails. Users are advised that some ETFE insulations are known to out-gas trace amounts of corrosive fluorine over time. When this wire is used with nickel coated m  read more..

About Radon

You want to take good care of your family. You try to eat healthy foods. You take your children to the doctor for regular checkups. You try your best to protect your family from accidents and illness. You want to live in a safe neighborhood and home. But did you know your home might have hidden Radon Mitigation About Radon  read more..

Structural Drying

Convalescent heat substitute is a worldwide skill appropriate to vapor-density, direct-growth, and cooled-water air-handling-unit (AHU) coils; heat-driven desiccant Dehumidification Structural Drying equipment; dehumidifiers; supermarket, ice-rink, and natatorium air-conditioning and dehumidification systems; and bundled   read more..

Roof Damage Insurance Claim Tips

Roofing systems commonly rely on roof sheathing and bottom chords to provide lateral support for the roof trusses. Oliver and Hanson (1994) and Riba et al. (1994), agree that roofing systems could be considerably improved if simple secondary bracing were installed between Wind Damage Roof Damage Insurance Claim Tips trusses.&nbs  read more..

Hurricane Safety Procedures

The contractor must submit drawings to DCAM through the Department or Agency for approval of any windows or openings to be sealed by any method other than that shown in sketches listed in number 1 above.9. For windows over 48 inches wide or 96 inches in height, the contractor must submit drawings to  read more..

Basement Drying

Waste that begins in the erected milieu is deposited or flows past the confines of the edifice's disposal systems. In that instance, there is smaller or confined flooding, but water and waste entered the structure and furniture of the edifice. For example, flooding happens in a men's lavatory  read more..

Emergency Board Up

Plywood shutters that you create yourself, if placed correctly, could provide a high degree of Wind Damage Emergency Board Up coverage from flying debris during a storm. Plywood shutters could be placed on all kinds of houses. Measure every window and every door that has glass, and add 8 inches to all the height and w  read more..