Meth Lab Cleanup >> Chemicals Used In Meth Labs

Another meth cooking method that is not that common, but can be found is the Amalgam or P2P method,which primarily uses phenyl-2-propanone (P2P) and methylamine along with lead acetate and mercuricchloride. Other chemicals used in this method include Chemicals Used In Meth Labs aluminum, hydrochloric acid, isopropyl alcohol,methanol, ethanol, acetone, benzene, chloroform and ether. Elevated levels of lead and mercury can bepresent following this type of lab.
 
The "cooking" of meth can involve a large variety of chemical reagents depending on the specific methodof manufacture. In general, the process involves precursor reagents, organic solvents, and reactivereagents that facilitate the conversion of the precursor into meth. The Chemicals Used In Meth Labs chemicals used are typicallypurchased, stolen, or illegally manufactured. Even though many of these chemicals are commonly foundin households and can be "safe" if used appropriately, their inherent dangers are exacerbated when usedinappropriately or in combination with other chemicals during the meth production process. Improperstorage and disposal of these chemicals and mixtures also creates hazards.
 
Exposures and health concerns are greatest during the cooking processes. The levels of airbornechemicals vary greatly with the different cooking methods, the specific chemicals used, and the Chemicals Used In Meth Labs scale ofthe production, the size of the room or structure, and the ventilation of the cooking area. Generalconcerns include the risk of fires or explosions due to usage of flammable solvents, respiratory difficultiesfrom breathing toxic or corrosive vapors, and skin irritations from strongly acidic and basic solutions.
 
Chronic exposure to meth production may cause long-term health problems. Drug paraphernalia such asneedles present possible exposure to infectious agents such as HIV and Hepatitis B and other bloodborne pathogens. After the cooking Chemicals Used In Meth Labs process has stopped, most of the hazards decrease. In addition, proper removalof the production wastes and bulk chemical supplies eliminates many of the risks associated withclandestine meth labs. Volatile chemicals and solvents such as ammonia, methanol, ether, or acetonewill move into air and will be readily removed from the structure by ventilation.
 
However, some residual contamination created from repeated "cooks" can persist long after allproduction has ceased. Semi- or non-volatile production chemicals such as acids, bases, and othercorrosives, precursor chemicals, Chemicals Used In Meth Labs and products used or created in the manufacturing processes are morepersistent. These residual chemicals can be volatilized or aerosolized during the cooking process anddeposit on surfaces and in materials (such as carpeting, fabrics, and building structure materials).
 
Meth can be found on most surfaces, building materials, and home furnishings of a clandestine lab. Research done by National Jewish Hospital suggest that re-volatilization of meth may Chemicals Used In Meth Labs occur after theinitial deposition. Meth and other fine particle contaminates can be aerosolized and dispersed throughoutthe former lab. Refer to Table A, Meth Production Chemicals Present in Active and Former Meth Labs (below) forcomparison of active meth lab dangers to residual contaminants remaining after meth production ceases. Regarding Table A:
 
• The former meth lab environment is much less hazardous than the active lab environment. Asindicated in the last column, the solvents have dissipated and the reactive materials have Chemicals Used In Meth Labs beenmostly reduced or depleted; existence of either is far less in the former meth lab than in an activemeth lab.
 
• Not all the chemicals listed in Table A will be found in every meth lab. Reaction materials useddepend upon the Chemicals Used In Meth Labs method of production. The solvent(s) used in each cooking process may varydue to availability, cook's preference, etc.
 
Extracting Precursor Drug Use: Cold tablets, Chemicals Used In Meth Labs solvents and coffee filters
Wastes: Solvent vapors, ephedrine or pseudoephedrine, binder from tablets, and coffee filters. Solvent evaporates or may be reused.
 
Red Phosphorus (Red P)
 Method Use: Iodine, red phosphorus, filters, heat, sodium hydroxide, and ether or othersolvent(e.g., hexane, toluene).Wastes: Iodine, red phosphorus, sodiumhydroxide, coffee Chemicals Used In Meth Labs filters, and solvent gasesand possible other by-products. solventvapors, Iodine sublimation
 
Anhydrous Ammonia (Nazi)
Method Use: Sodium, potassium, or lithium metal, Chemicals Used In Meth Labs anhydrous ammonia, water, ether or othersolvent.(Heat may be used to expedite solventevaporation. Exothermic reaction can causegaseous by-products)Wastes: Coffee filters, excess metal.
 
"Salting Out‚”
Use: Rock salt or table salt, sulfuric or muriatic acid, filters. Wastes: Excess salt, sulfuric or muriatic acid, hydrochloric Chemicals Used In Meth Labs acid, hydrogen chloride gas, coffeefilters, meth, solvent from above phases, possibly acetone.- 43 -Appendix B.1:Methamphetamine 
 
Surface Wipe Sampling Procedure
Wipe sampling is performed to establish the presence of meth on non-porous surfaces. Samples shall betaken using methanol-dampened wipes. Wipe material can be sterile filters, gauze Chemicals Used In Meth Labs pads or swabs andcan be obtained pre-prepared from an environmental laboratory.Water-dampened wipes shall not be approved by this guidance due to the lack of meth capture by waterdampened samples. The sampler shall have clean hands and shall wear gloves during each samplingevent to prevent the introduction of contamination or cross contaminating sample areas.
 
 The sampling area shall be a relatively dry surface. Post-decontamination wipe sampling shall be performed afterwashing and painting or sealing of walls and surfaces. Procedure includes:
1. Sampler dons a clean pair of latex or other chemically-protective gloves.
2. Sampler attaches 10 centimeter (cm) by 10 cm template or measures with a ruler and marks byusing tape a pre-designated Chemicals Used In Meth Labs sampling location or area. (Sampler shall avoid touching the areawithin tape/template as to not disturb sampling area.) The sampler can either mark one sample ata time, or mark off all areas to be sampled within the structure at once. Photograph sample siteswith an identifying reference point.
 
3. Sampler dons a clean pair of gloves Chemicals Used In Meth Labs to begin sampling.
4. Either soak the sampling wipe (filter or gauze pad) with 2 mL methanol or take the wipe out of apre-soaked container. Use dampened wipe within 5 seconds of applying methanol to ensure that the wipe is damp. A dry wipe shall not capture a representative meth sample.
 
5. Applying firm pressure, wipe the surface area within the template/taped area by starting at theoutside Chemicals Used In Meth Labs edge working towards the center of the surface area by wiping in concentric squares ofdecreasing size until the area inside the template has been wiped. Avoid wiping the marking tapeor template. Fold the wipe so the sampled side is folded in.
 
6. Insert the wipe into the sample jar and close the lid tightly.
7. Record the exact location, including the room and the approximate height (from the floor), dateand time of the sample Chemicals Used In Meth Labs on the sample container, the chain of custody form and sampling notebook.
8. Properly dispose of gloves and marking tape and proceed to the next sampling location.

Remove Toxic Smoke Damage From An Apartment Fire

The newly-created Coalition for Fire-Safe Cigarettes issued a call to the tobacco companies today to produce and sell only "fire-safe ” cigarettes nationwide. Fire Damage Remove Toxic Smoke Damage From An Apartment Fire

The Coalition, which is being launched today, is a national group of fire service members, consumer, e  read more..

How To Get Ready For A Hurricane

Flash floods can occur within a few minutes or hours of excessive rainfall, a dam or levee failure, or a sudden release of water held by an ice jam. Flash floods often have a dangerous wall of roaring water carrying rocks, mud and other debris. Overland flooding, Emergency Board up How To Get Ready For A Hurricane the most common type   read more..

Flood Water Management Act

What should I do with the sample?Fill out the sample label and form provided by the lab. Place the bottle in a clean cooler or othercontainer with ice in a sealed plastic bag or with blue ice to keep the sample chilled. Deliver orship the sample to your chosen laboratory within the time period Water Damage Flood Water Management Act&  read more..

Mold Remediation

Meth Lab Cleanup Mold Remediation, that are used to make the unlawful drug methamphetamine, are found manufacturing in houses, rented apartments, motel rooms, side sheds, and even motor vehicles. Federal, state and local law enforcement were credited in the appropriation of thousands of meth labs across the country, and   read more..

Roof Damage

Home damage and loss from hurricanes have amplified with population progression in coastal areas, and climatic issues point to more common and powerful hurricanes in the upcoming. This article explains potential hurricane dangers from wind and water. Wind Damage Roof Damage to residential homes from three lates  read more..

How To Restore Smoke Damaged Pictures

Outside Surveyor/Disadvantages

1. An outside surveyor does not know the history or institutional framework in which situations exist. A consultant is unfamiliar with institutional traditions and idiosyncrasies and, as a result, may make recommendations that are unrealistic or Document restoration How To Restore Smoke Damaged Pictures ou  read more..

Carpet Cleaning After Water Damage

The Federal Emergency Management Agency and the city of New Orleans recently announced additional Katrina-related grants totaling nearly $7 million that will directly benefit two recovery projects within the city – the Joe Brown Center in New Orleans East and Water Extraction Carpet Cleaning After Water Damage the Municipal Yacht Harb  read more..

Spot A Meth House In Your Neighborhood

 
Handling of Furnishings and Porous MaterialsAbsorbent materials can accumulate vapors that are created and dispersed during thecooking pr  read more..

Detoxify From Radon Exposure

An applicant who wishes to enroll in the RPP with a device that is not included in the Application Device Check lists must follow EPA's procedure for entering new devices into the Program. This procedure has three stages: (1) the applicant submits an Application to enter the new Radon Mitigation Detoxify From Radon Exposure devic  read more..

Small Contractors And Lead Paint

Small contractors are an especially difficult audience to reach with a safety message, and yet there are thousands of them across the United States who, on a daily basis, direct thousands of employees in their work. Most construction companies are small, and the way in which health and safety practi  read more..