Another meth cooking method that is not that common, but can be found is the Amalgam or P2P method,which primarily uses phenyl-2-propanone (P2P) and methylamine along with lead acetate and mercuricchloride. Other chemicals used in this method include Chemicals Used In Meth Labs aluminum, hydrochloric acid, isopropyl alcohol,methanol, ethanol, acetone, benzene, chloroform and ether. Elevated levels of lead and mercury can bepresent following this type of lab.
 
The "cooking" of meth can involve a large variety of chemical reagents depending on the specific methodof manufacture. In general, the process involves precursor reagents, organic solvents, and reactivereagents that facilitate the conversion of the precursor into meth. The Chemicals Used In Meth Labs chemicals used are typicallypurchased, stolen, or illegally manufactured. Even though many of these chemicals are commonly foundin households and can be "safe" if used appropriately, their inherent dangers are exacerbated when usedinappropriately or in combination with other chemicals during the meth production process. Improperstorage and disposal of these chemicals and mixtures also creates hazards.
 
Exposures and health concerns are greatest during the cooking processes. The levels of airbornechemicals vary greatly with the different cooking methods, the specific chemicals used, and the Chemicals Used In Meth Labs scale ofthe production, the size of the room or structure, and the ventilation of the cooking area. Generalconcerns include the risk of fires or explosions due to usage of flammable solvents, respiratory difficultiesfrom breathing toxic or corrosive vapors, and skin irritations from strongly acidic and basic solutions.
 
Chronic exposure to meth production may cause long-term health problems. Drug paraphernalia such asneedles present possible exposure to infectious agents such as HIV and Hepatitis B and other bloodborne pathogens. After the cooking Chemicals Used In Meth Labs process has stopped, most of the hazards decrease. In addition, proper removalof the production wastes and bulk chemical supplies eliminates many of the risks associated withclandestine meth labs. Volatile chemicals and solvents such as ammonia, methanol, ether, or acetonewill move into air and will be readily removed from the structure by ventilation.
 
However, some residual contamination created from repeated "cooks" can persist long after allproduction has ceased. Semi- or non-volatile production chemicals such as acids, bases, and othercorrosives, precursor chemicals, Chemicals Used In Meth Labs and products used or created in the manufacturing processes are morepersistent. These residual chemicals can be volatilized or aerosolized during the cooking process anddeposit on surfaces and in materials (such as carpeting, fabrics, and building structure materials).
 
Meth can be found on most surfaces, building materials, and home furnishings of a clandestine lab. Research done by National Jewish Hospital suggest that re-volatilization of meth may Chemicals Used In Meth Labs occur after theinitial deposition. Meth and other fine particle contaminates can be aerosolized and dispersed throughoutthe former lab. Refer to Table A, Meth Production Chemicals Present in Active and Former Meth Labs (below) forcomparison of active meth lab dangers to residual contaminants remaining after meth production ceases. Regarding Table A:
 
• The former meth lab environment is much less hazardous than the active lab environment. Asindicated in the last column, the solvents have dissipated and the reactive materials have Chemicals Used In Meth Labs beenmostly reduced or depleted; existence of either is far less in the former meth lab than in an activemeth lab.
 
• Not all the chemicals listed in Table A will be found in every meth lab. Reaction materials useddepend upon the Chemicals Used In Meth Labs method of production. The solvent(s) used in each cooking process may varydue to availability, cook's preference, etc.
 
Extracting Precursor Drug Use: Cold tablets, Chemicals Used In Meth Labs solvents and coffee filters
Wastes: Solvent vapors, ephedrine or pseudoephedrine, binder from tablets, and coffee filters. Solvent evaporates or may be reused.
 
Red Phosphorus (Red P)
 Method Use: Iodine, red phosphorus, filters, heat, sodium hydroxide, and ether or othersolvent(e.g., hexane, toluene).Wastes: Iodine, red phosphorus, sodiumhydroxide, coffee Chemicals Used In Meth Labs filters, and solvent gasesand possible other by-products. solventvapors, Iodine sublimation
 
Anhydrous Ammonia (Nazi)
Method Use: Sodium, potassium, or lithium metal, Chemicals Used In Meth Labs anhydrous ammonia, water, ether or othersolvent.(Heat may be used to expedite solventevaporation. Exothermic reaction can causegaseous by-products)Wastes: Coffee filters, excess metal.
 
"Salting Out‚”
Use: Rock salt or table salt, sulfuric or muriatic acid, filters. Wastes: Excess salt, sulfuric or muriatic acid, hydrochloric Chemicals Used In Meth Labs acid, hydrogen chloride gas, coffeefilters, meth, solvent from above phases, possibly acetone.- 43 -Appendix B.1:Methamphetamine 
 
Surface Wipe Sampling Procedure
Wipe sampling is performed to establish the presence of meth on non-porous surfaces. Samples shall betaken using methanol-dampened wipes. Wipe material can be sterile filters, gauze Chemicals Used In Meth Labs pads or swabs andcan be obtained pre-prepared from an environmental laboratory.Water-dampened wipes shall not be approved by this guidance due to the lack of meth capture by waterdampened samples. The sampler shall have clean hands and shall wear gloves during each samplingevent to prevent the introduction of contamination or cross contaminating sample areas.
 
 The sampling area shall be a relatively dry surface. Post-decontamination wipe sampling shall be performed afterwashing and painting or sealing of walls and surfaces. Procedure includes:
1. Sampler dons a clean pair of latex or other chemically-protective gloves.
2. Sampler attaches 10 centimeter (cm) by 10 cm template or measures with a ruler and marks byusing tape a pre-designated Chemicals Used In Meth Labs sampling location or area. (Sampler shall avoid touching the areawithin tape/template as to not disturb sampling area.) The sampler can either mark one sample ata time, or mark off all areas to be sampled within the structure at once. Photograph sample siteswith an identifying reference point.
 
3. Sampler dons a clean pair of gloves Chemicals Used In Meth Labs to begin sampling.
4. Either soak the sampling wipe (filter or gauze pad) with 2 mL methanol or take the wipe out of apre-soaked container. Use dampened wipe within 5 seconds of applying methanol to ensure that the wipe is damp. A dry wipe shall not capture a representative meth sample.
 
5. Applying firm pressure, wipe the surface area within the template/taped area by starting at theoutside Chemicals Used In Meth Labs edge working towards the center of the surface area by wiping in concentric squares ofdecreasing size until the area inside the template has been wiped. Avoid wiping the marking tapeor template. Fold the wipe so the sampled side is folded in.
 
6. Insert the wipe into the sample jar and close the lid tightly.
7. Record the exact location, including the room and the approximate height (from the floor), dateand time of the sample Chemicals Used In Meth Labs on the sample container, the chain of custody form and sampling notebook.
8. Properly dispose of gloves and marking tape and proceed to the next sampling location.

Landlord Tenant Eviction Notice

Residential service is provided once a week on your designated day of collection. If you need to know your collection day, we have provided a zone collection map on this web site. You can contact customer service at 864-467-4345 for further assistance. Please place all household garbage and other mi  read more..

Flood Prevention Technology

Generally, physical damage to your building or personal property "directly” caused by a flood is covered by your flood insurance policy. For example, damages caused by a sewer backup are covered if the backup is a direct result of flooding. However, if the backup is caused by some other problem,   read more..

Remove Smoke Odor From Fabric

Anaerobic digesters are designed to optimize waste degradation and capture the gaseous by-products, primarily carbon dioxide and methane. Methane can be used on-farm for heating through a furnace or in electricity production. Mesophilic digesters are the most common type, and support a bacterial pop  read more..

How To Rebuild Fire Damaged Homes

Pressure wash, scrub or disinfect all exterior surfaces including walls, walks, drives, decks, window and Fire Damage How To Rebuild Fire Damaged Homes deck screens, etc. Wash and disinfect all interior walls and hard surfaces with mild soap or other appropriate cleaning solutions or products, and rinse thoroughly.

Don't   read more..

Asbestos Abatement

If you are reading this article, it is most likely that an Tenant Move Out Cleanup Asbestos Abatement will be performed nearby to your home or office in the future. While not inclusive, this article will try to answer many of the usual inquiries that most people might have under these conditions. Asbestos-containing building mater  read more..

Homicide Cleanup

Crime scene cleanup, homicide cleanup


People that talk to a crime scene cleanup professional, usually say the same thing. You've probably seen it all. Horrific Crime Scene Cleanup Homicide Cleanup like shotgun suicides, violent double homicides, decomposing bodies from su  read more..

Basement Drying

When a Fire Damage Basement Drying strikes, many lives could be suddenly turned upside down, many times the hardest part is knowing exactly where to start and who you should contact. The Federal Emergency Management Agency’s (FEMA) along with the United States Fire Administration (USFA) has collected the foll  read more..

How To Fix A Wet Crawl Space From Mold

Set your home's thermostat at the coolest level you can without making your rooms uncomfortable. For most homes, the heating bill drops by about 2 percent for every 1 degree the thermostat is lowered. Crawl Space Drying How To Fix A Wet Crawl Space From Mold Lower your home's thermostat at bedtime or while you're away during the day.     read more..

Mold And Mildew From Flash Floods

Following a widespread flooding disaster, many questions arise from citizens within the communities affected and from the many volunteers and organizations that are working in the devastated area. Personal health and safety is a priority for everyone. The following information is aimed at preventing  read more..

How To Clean Up Cigarette Smoke Odor

Saitoh and Inukai contend that humidity is probably the most important factor in determining the amount of corrosion that occurs [80]. They also note that the combustion gases from materials such as wood and asphalt that are not expected to produce HCl still produce corrosion. They surmise the prese  read more..