Meth Lab Cleanup >> Drug Lab Clean-Up

Burning a meth-contaminated structure in lieu of decontamination is prohibited, unless priorapproval has been granted. Approval shall be obtained from the Kentucky Division for Air Quality Drug Lab Clean-Up prior to a training or practice burn. Safety of firefighter entry into a former meth lab structure and effectivenessof decontamination of firefighter equipment cannot be assured. In all cases of a practice or training burn,the burn shall be done in accordance with demolition and asbestos regulations.
 
VI. POST-DECONTAMINATION SAMPLINGA.
 General Sampling IssuesPost-decontamination samples shall be taken after washing and sealing/painting of surfaces. The Drug Lab Clean-Up certified contractor may take wipe samples after washing of surfaces only if the decontamination standardhas been achieved. However, the sealing/painting step helps to provide an additional layer of protection.Some studies have shown that elevated levels of meth may "wick” through the paint, but if the doublewashing is done, it is anticipated that the main meth mass shall be removed before painting or sealing
 
B. Sampling ProtocolsEach room and space in the inhabitable property shall be sampled. Procedures for meth wipe samplingare provided in Appendix B.1. In all cases, a representative number of discrete samples shall be biasedand collected in the areas of Drug Lab Clean-Up suspected cooking, observed chemical spills, or waste storage areasidentified during the Preliminary Assessment of the inhabitable property. Table 3 lists the minimumnumber of composite samples that shall be required for post-decontamination sampling. All samples shallbe collected from cleaned surfaces and not new materials.
 
 If a wall or material identified below isremoved and replaced as part of the decontamination, the contractor can designate another location forsampling and document in the Contractor’s Certificate of Decontamination, DEP 5035, January 2009.Table 3Post-Decontamination Sampling ProtocolsArea Sampling ProtocolEach Room (4) ten cm x ten cm samples for total of 400 sq. cmconsisting of :(1) sample from location at or near center of floor*(1) sample from Drug Lab Clean-Up location at or near center of ceiling(1) sample from location at or near center of (2) walls(Samples can make up one (1) composite sample foreach room) + the following samplesKitchen (4) ten cm x ten cm samples for total of 400 sq. cmconsisting of:(1) sample from countertop(1) sample from stovetop(1) Range hood above stovetop (if present).
 
 If notpresent from a cabinet above the stovetop. ) Floor in front of the stovetop(Samples can make up one composite sample)Bathroom(s) (4) ten cm x ten cm samples for total of 400 sq. cm Drug Lab Clean-Up consisting of:(1) sample from countertop(1) sample from sink(1) sample from toilet(1) sample from shower or bathtub(Samples can make up one composite sample)HVAC System (4) ten cm x ten cm samples for total of 400 sq. cm atfour (4) different locations in the ventilation system.
 
Mustsample cold air returns or plenums. (Samples can makeup one composite sample)Appliances(Cleaned)One (1) ten cm x ten cm sample from exposed surfaceof each cleaned appliance. If multiple appliances arepresent, up to four (4) wipes can be Drug Lab Clean-Up combined into onecomposite sample representing 400 sq. cm.* If the flooring is carpeting that has only been cleaned and not removed, the floor sample can betaken from the lowest point on one wall nearest the cooking area, or just above the baseboard innon-cooking rooms.
 
All samples collected and analyzed shall be below the decontamination standard of 0.1 µg/ 100cm2. Inaddition to the samples noted in Table 3, the certified contractor shall also collect Drug Lab Clean-Up quality assurance andquality control wipe samples and field blanks in accordance with standard sampling and analyticalpractices. The contractor shall log all samples collected at the site and any QA/QC samples on a chain ofcustody form, maintain proper temperature and maintain records of sample shipment to the laboratory.
 
C. Analytical Laboratory RequirementsCertified contractors shall be required to use an EPA or otherwise nationally-accredited analyticallaboratory to ensure that all analytical data are reliable and reproducible. For methamphetamineanalyses, the laboratory must utilize Method 8270C-Modified, "Semi-volatile Organic Drug Lab Clean-Up Compounds byLiquid Chromatography or Gas Chromatography/Mass Spectroscopy”, from "Test Methods for EvaluatingSolid Waste, Physical/Chemical Methods”, U.S. EPA SW-846, Third Edition (Nov. 1986), Revision 3(Dec. 1996), or other accredited laboratory methods to achieve a detection limit of at least 0.1 µg/ 100cm2, and include all quality assurance/quality control documentation required by the method.
 
 Many laboratories are certified in other states to analyze for meth and other precursors or are using updatedmethods and equipment that are equivalent to Method 8270. Data from these laboratories shall Drug Lab Clean-Up beaccepted. For all other waste or chemical analyses requiring an off-site environmental laboratory, EPASW-846 methods must be utilized. It is the responsibility of the certified contractor to ensure thatthe laboratory used is an accredited laboratory and is capable of performing the requiredanalyses.
 
VII. EXTERIOR EVALUATIONA.
Septic System EvaluationLarge volumes of meth lab wastes can pose a problem if they are flushed and end up in a septic Drug Lab Clean-Up system.It is believed that the micro-organisms present in the septic system can biologically break down many of the chemicals, however if a meth lab operated for a long period of time, under extreme pH conditions, itcould cause damage to the operation of the system.
 
 If there is evidence that meth lab wastes may havebeen disposed into the septic system, field screening of the septic tank must be performed by thecertified contractor. Evidence of waste disposal may include the following: witness statements; stained oretched sinks, bathtubs, toilets; chemical odors coming from plumbing or septic tank; or visualobservations of unusual conditions within the tank (dead tank); or stressed or dead vegetation in a drainfield; or if identified on Tier Assessment form.
 
 Initial field screening during a Tier 3 response selection shall include monitoring the septic tank for VOCsusing a PID or FID; and testing the pH of the liquid in the septic tank using pH paper or pH meter.Additional screening or testing shall be performed according to the Tier response level. Samples shall becollected of the septic wastes in the tank for toxicity characteristic leaching procedure (TCLP) and otherwaste characterization parameters Drug Lab Clean-Up to determine if the wastes are hazardous, and arrangements shallneed to be made with an approved waste handling contractor, transporter, and disposal facility to havethe septic tank contents pumped out and properly disposed in accordance with state and federalregulations. Do not remove or dispose of the tank contents until proper testing has been done.

Mold In Apartemens Mold In Rentals

Separation of rents and obligations to maintain property forbidden.A rental agreement, assignment, conveyance, trust deed, or security instrument may not permit the receiptof rent free of the obligation to comply with AS 34.03.100 (a).Sec. 34.03.060. Sublease Tenant Move Out Cleanup Mold In Apartemens Mold In Rentals and assignment.(a) Unless  read more..

Waterproof A Basement For Severe Flooding

Remove water trapped within your walls. To check for water,take off the baseboard. Stick an awl or knife into the wall about 2 inches above the floor (just above the 2 X 4 wood sill plate). If water drips out, cut or Flood Damage Waterproof A Basement For Severe Flooding drill a hole large enough to allow water to drain freely. (Use a hand or cordl  read more..

Leaking Toilet Base

Burst Pipe Floods Basement Areas On the front page...Late Tuesday evening, June 26, the Clinical Center experienced one of the worst floods in its history when a water booster pump vibration eliminator on a chilled- water pipe burst and ran for 40 minutes before it was detected Water Damage Leaking Toilet Base and st  read more..

Compulsive Hoarding Safety

Until the last few years, people didn't know much about hoarding, the since television has started to show people's homes and the different conditions of Hoarding Compulsive Hoarding Safety. Now everyone is beginning to take notice, even to the point that some cases have been deemed, illegal because of the obvious threat t  read more..

Asbestos Exposure

What is asbestos exposure? Asbestos exposure is the name given to a group of minerals that occur naturally in the environment as bundles of fibers that can be separated into thin, durable threads. These fibers are resistant to heat, fire, and chemicals and do not conduct electricity. For these reaso  read more..

Desiccant Vs Mechanical Dehumidification

System description and operation principle Various low-temperature desalination units have been constructed base on the principle of humidification-dehumidification. The basic principle of all these techniques is to convert salt water to humidified air and Dehumidification Desiccant Vs Mechanical Dehumidification then condense the water vapo  read more..

Hail Damage

Hurricane waves move near shore until the water becomes shallow enough to start wave breaking. The extreme breaker height in shallow water is a purpose of water depth; bottom slope; and Wind Damage Hail Damage event wave height and phase. Larger waves originally break some expanse offshore, then restore and per  read more..

Crime Trauma Scene Decontamination Training

CRIME SCENE WASTE A. If the crime has occurred on an Individual Parcel, the Police Department will advise the responsible party to contact a private cleanup company. Crime Scene Cleanup Crime Trauma Scene Decontamination Training The list of city approved cleanup firms may be provided upon request. 

If a police inc  read more..

Structural Drying Log

If an intrusive/penetrating moisture meter is not available, a non-intrusive, penetrating moisture meter (Figure 3b) may be used; however, keep in mind that the material moisture results measured from non-intrusive meters may be less accurate than intrusive meters. Kitchen cabinets, bathroom vanitie  read more..

Tenant Junk Removal

Housing codesThe primary purpose of housing codes is to protect the health and safety of the people who live in housesand apartments.A minimum standard of maintenance is set, making the landlord (not the tenant) responsible for keeping Tenant Move Out Cleanup Tenant Junk Removal rental property in decent shape. (See: "The landl  read more..