Meth Lab Cleanup >> How To Report Meth Labs

Dispose of all contaminated contents in a sanitary landfill. Structural Cleaning: (a) HEPA vacuum porous building materials such as concrete block, brick,raw wood studs, wooden floors and all floors under How To Report Meth Labs removed carpeting. (b) Double wash withdetergent and hot water, followed by a thorough rinse with clean water. Alternatively, concreteand raw wood can be steam cleaned with extraction.
 
 Area Segregation: After each room is cleaned, cordon off doors and openings to other roomsusing (at least) 4-mil plastic sheeting to avoid recontamination. HVAC Cleaning: Clean heating, ventilation and air conditioning (HVAC) system. Replace filtersat the end of the decontamination process. Encapsulation: Encapsulate residual contaminants with two coats of sealant or paint. Paintshould be How To Report Meth Labs sprayed and not brushed or rolled.
 
 Paint should be allowed to cure for therecommended time between coats. Final Ventilation: Ventilate structure for at least two days after cleaning. Exterior (Outdoors) Evaluation: Perform outdoor investigation including the septic system andcontact KDWM if evidence of dumping or releases of hazardous substances are noted. See Sec.VII Exterior Evaluation. entilation of the structure is recommended before, during and after How To Report Meth Labs the decontamination processexcept when ventilation may interfere with air sampling.
 
Open all windows and use exhaust fans,blowers and/or negative air machines for a minimum of two (2) days for a Tier 1 Response to five (5)days for a Tier 3 Response, before and after cleaning. Take care that vented contaminants are notexhausted to air intakes of adjacent How To Report Meth Labs structures. Do NOT operate the HVAC system until the entirestructure is decontaminated in order to prevent spread of contaminants. Also take care to provideadequate ventilation during sampling and painting.
 
Respiratory protection may be necessary as part ofPPE during decontamination, if adequate ventilation cannot be achieved (e.g., in very cold weather); during the use of solvent cleaners or sampling materials; while removing carpeting and other highlycontaminated materials.I. Indoor Air Quality TestingIndoor ambient air should be screened before and after the decontamination process (or during theprocess as deemed How To Report Meth Labs necessary by the certified contractor) using a Photoionization Detector (PID), FlameIonization Detector (FID) or similar instrument.
 
Initially, a sweep through the entire building shall bemade with an accurate record kept of all readings in every room. VOC sampling shall be conducted inaccordance with the procedures in Appendix B.2. This will also assist the certified contractor indetermining the proper level How To Report Meth Labs of PPE for the workers. Additionally, each septic system drain (floor, tubs,sinks) shall be tested with the PID to determine if any chemicals have accumulated in the drain trap.
 
J. Heating Ventilation and Air Cooling (HVAC) SystemAssessment of HVAC system shall be performed early in the decontamination process. Do NOT operatethe HVAC system until the entire structure is decontaminated in order to prevent spread ofcontaminants. Depending on the recommended Tier Response level, assessment and the system, thefollowing steps may be required: During the decontamination of How To Report Meth Labs each room or area:o Remove and clean, or replace all vents.o Thoroughly HEPA-vacuum the ductwork and clean the entire HVAC system.
 
 Flexible ductwork may be difficult to clean, and in some cases may promote mold growth if thewater used during cleaning is not completely removed. Therefore, it is recommended thatthis ductwork be removed and replaced. Remove and clean, or replace supply diffusers. Replace all filters in the system at the end of the decontamination process and How To Report Meth Labs after all dustdisturbances have occurred.K. Evaluation of Chemical SpillsAll food preparation counter-tops, stained materials, powders and liquids throughout the structure shallbe pH tested (see Appendix B2) to determine their corrosivity.
 
An accurate record of findings should bemade. Surface pH sampling shall be conducted in accordance with the procedures in Appendix B2.Acids shall be neutralized with sodium bicarbonate (baking soda); and bases with weakly acidic washsolutions (e.g., vinegar, citric or acetic acid). Solids shall be containerized for proper waste disposal.Liquids shall be How To Report Meth Labs adsorbed with clay or another non-reactive material and packaged for proper wastedisposal. Litmus paper shall be used to check a surface after neutralization.
 
Stained or visiblycontaminated materials shall be removed and disposed.L. Structure Contents and FurnishingsAs a rule, most personal belongings found in a former meth lab structure are presumed contaminatedand shall be discarded. At the discretion of the property owner in consultation with the certifiedcontractor, some items may be: (a) cleaned without sampling, (e.g., eye glasses, adults’ clothing, majorappliances) or (b) cleaned and sampled (e.g., high-cost, low contact large furniture and appliances, andother items). Decisions shall be based not only on cost-effectiveness and value of the item, but also onthe potential future use of the items, How To Report Meth Labs and potential for contact.
 
 Table 2 and the following text providesome guidance and recommendations for evaluating the contents of the structure. Evaluation of Personal ItemsHigh Value – High Contact ItemsE.G., Mattresses, carpeting, large upholstereditems should almost always be discarded.(See exceptions in text.)High Value – Low Contact ItemsE.G., In some circumstances, photographs may besalvaged without cleaning, or large appliances maybe cleaned and saved.Low Value – High Contact ItemsE.G., clothing, plastic toys and toothbrushshould always be discarded.(See exceptions in text.)Low Value – Low Contact ItemsE.G., A How To Report Meth Labs screw driver, garden rake or other metal orhard material item may be cleaned in some circumstances.
 
Household contents and guidance for their disposition are listed below. This list is not exhaustive.Recommendations for household How To Report Meth Labs contents are divided into three categories:1) Always Discard, 2) Disposal Strongly Recommended and 3) Disposal Recommended. Infants’ and Small Children’s Clothes, Toys, Furniture and Personal Items:Always Discard.
 
Exceptions: Metal or other hard medical devices such as glasses or orthopedic devices that canbe cleaned may be exempted in consultation with the contractor regarding decontamination How To Report Meth Labs options. Other Fabric Goods:Disposal Strongly Recommendedwater. Any item that shows evidence of use for meth cooking (e.g. acid etching, chemicalstaining) must be discarded.

Animal Damage Control

To be eligible for the State Wildlife Grants (SWG) Program each state was required to develop a Wildlife Action Plan (WAP) and submit it to the National Advisory Acceptance Team (composed of staff from the states and the U.S. Fish and Wildlife Service) by October 2005. Each Plan was required to incl  read more..

Remove The Smell Of Fire Damage From Wood Furnitur

TheFire Protection Research Foundation, an affiliate of theNational Fire Protection Association (NFPA), Fire Damage Remove The Smell Of Fire Damage From Wood Furnitur  resented the William M. Carey Award to the authors of a paper titled "Results of a Clinical Study of the Waking Effectiveness of Fire Signaling Devices.” 

  read more..

Protecting Your Home

Wind can tear the roofs from buildings, rip siding from exterior walls, and throw debris through windows. Falling trees can crush roofs and walls. Of course, hurricanes and Wind Damage Protecting Your Home tornadoes generate exceptionally destructive winds that can turn buildings into piles of rubble. But high winds   read more..

Mold Symptoms

Kern County, in the San Joaquin Valley, California, is one of the most highly coccidioidomycosis-endemic regions. The number of new cases of coccidioidomycosis in the area has varied widely from year to year; a low incidence of coccidioidomycosis from 1987 to 1990 (<500 reported cases a year in K  read more..

Asbestos Tile

Yes No Top of Form How can we make better? (250 Character max.) We are collecting this info under OMB clearance number 1225-0059 Bottom of Form Thank you for your feedback! Please Contact Us if you have any other Asbestos Abatement Asbestos Tile comments or questions!  Thank you for your July 27 letter regarding the   read more..

How To Clean After Tenants

When the tenant moves out of a rental unit, the landlord has thirty (30) days in which to either return the entire security deposit plus interest if appropriate, or send a written statement of any deductions made from the deposit for repairs, cleaning, etc., the cost of each repair (supported by cop  read more..

Will Acrylic Primer Seal Lead Paint

The engineering controls and work practices associated with the employee's job assignment including training of employees to follow relevant good work practices described in Appendix B of this section; The contents of any compliance plan and Lead Paint Removal Will Acrylic Primer Seal Lead Paint the location of regulated areas in effect.   read more..

Risks Of Being A Crime Scene Clean Up Technician

Crime scene processing will begin after incident stabilization of the scene. Incident command priorities of life safety, search and rescue, and security precede crime scene preservation and processing. (05/15/96) Only the Watch Commander or Crime Scene Cleanup Risks Of Being A Crime Scene Clean Up Technician on-scene investigative supervisor can relinq  read more..

Radon Maps

Biological Air Pollutants Provide adequate outdoor air ventilation. Keep equipment water reservoirs clean. Eliminate standing water, wash bedding and soft toys frequently in hot water. Vacuum carpets and upholstered furniture regularly. Read more at www.epa.gov/iaq/biologic.html Volatile O  read more..

Freeze Drying Documents For Water Restoration

The best method of protecting vital records is through duplication and dispersal. The record's storage medium will dictate how it should be duplicated. Paper records may be photocopied or microfilmed on silver-halide film . (This is the only film type acceptable for preservation under ANSI/AIIM stan  read more..