Meth Lab Cleanup >> How To Report Meth Labs

Dispose of all contaminated contents in a sanitary landfill. Structural Cleaning: (a) HEPA vacuum porous building materials such as concrete block, brick,raw wood studs, wooden floors and all floors under How To Report Meth Labs removed carpeting. (b) Double wash withdetergent and hot water, followed by a thorough rinse with clean water. Alternatively, concreteand raw wood can be steam cleaned with extraction.
 
 Area Segregation: After each room is cleaned, cordon off doors and openings to other roomsusing (at least) 4-mil plastic sheeting to avoid recontamination. HVAC Cleaning: Clean heating, ventilation and air conditioning (HVAC) system. Replace filtersat the end of the decontamination process. Encapsulation: Encapsulate residual contaminants with two coats of sealant or paint. Paintshould be How To Report Meth Labs sprayed and not brushed or rolled.
 
 Paint should be allowed to cure for therecommended time between coats. Final Ventilation: Ventilate structure for at least two days after cleaning. Exterior (Outdoors) Evaluation: Perform outdoor investigation including the septic system andcontact KDWM if evidence of dumping or releases of hazardous substances are noted. See Sec.VII Exterior Evaluation. entilation of the structure is recommended before, during and after How To Report Meth Labs the decontamination processexcept when ventilation may interfere with air sampling.
 
Open all windows and use exhaust fans,blowers and/or negative air machines for a minimum of two (2) days for a Tier 1 Response to five (5)days for a Tier 3 Response, before and after cleaning. Take care that vented contaminants are notexhausted to air intakes of adjacent How To Report Meth Labs structures. Do NOT operate the HVAC system until the entirestructure is decontaminated in order to prevent spread of contaminants. Also take care to provideadequate ventilation during sampling and painting.
 
Respiratory protection may be necessary as part ofPPE during decontamination, if adequate ventilation cannot be achieved (e.g., in very cold weather); during the use of solvent cleaners or sampling materials; while removing carpeting and other highlycontaminated materials.I. Indoor Air Quality TestingIndoor ambient air should be screened before and after the decontamination process (or during theprocess as deemed How To Report Meth Labs necessary by the certified contractor) using a Photoionization Detector (PID), FlameIonization Detector (FID) or similar instrument.
 
Initially, a sweep through the entire building shall bemade with an accurate record kept of all readings in every room. VOC sampling shall be conducted inaccordance with the procedures in Appendix B.2. This will also assist the certified contractor indetermining the proper level How To Report Meth Labs of PPE for the workers. Additionally, each septic system drain (floor, tubs,sinks) shall be tested with the PID to determine if any chemicals have accumulated in the drain trap.
 
J. Heating Ventilation and Air Cooling (HVAC) SystemAssessment of HVAC system shall be performed early in the decontamination process. Do NOT operatethe HVAC system until the entire structure is decontaminated in order to prevent spread ofcontaminants. Depending on the recommended Tier Response level, assessment and the system, thefollowing steps may be required: During the decontamination of How To Report Meth Labs each room or area:o Remove and clean, or replace all vents.o Thoroughly HEPA-vacuum the ductwork and clean the entire HVAC system.
 
 Flexible ductwork may be difficult to clean, and in some cases may promote mold growth if thewater used during cleaning is not completely removed. Therefore, it is recommended thatthis ductwork be removed and replaced. Remove and clean, or replace supply diffusers. Replace all filters in the system at the end of the decontamination process and How To Report Meth Labs after all dustdisturbances have occurred.K. Evaluation of Chemical SpillsAll food preparation counter-tops, stained materials, powders and liquids throughout the structure shallbe pH tested (see Appendix B2) to determine their corrosivity.
 
An accurate record of findings should bemade. Surface pH sampling shall be conducted in accordance with the procedures in Appendix B2.Acids shall be neutralized with sodium bicarbonate (baking soda); and bases with weakly acidic washsolutions (e.g., vinegar, citric or acetic acid). Solids shall be containerized for proper waste disposal.Liquids shall be How To Report Meth Labs adsorbed with clay or another non-reactive material and packaged for proper wastedisposal. Litmus paper shall be used to check a surface after neutralization.
 
Stained or visiblycontaminated materials shall be removed and disposed.L. Structure Contents and FurnishingsAs a rule, most personal belongings found in a former meth lab structure are presumed contaminatedand shall be discarded. At the discretion of the property owner in consultation with the certifiedcontractor, some items may be: (a) cleaned without sampling, (e.g., eye glasses, adults’ clothing, majorappliances) or (b) cleaned and sampled (e.g., high-cost, low contact large furniture and appliances, andother items). Decisions shall be based not only on cost-effectiveness and value of the item, but also onthe potential future use of the items, How To Report Meth Labs and potential for contact.
 
 Table 2 and the following text providesome guidance and recommendations for evaluating the contents of the structure. Evaluation of Personal ItemsHigh Value – High Contact ItemsE.G., Mattresses, carpeting, large upholstereditems should almost always be discarded.(See exceptions in text.)High Value – Low Contact ItemsE.G., In some circumstances, photographs may besalvaged without cleaning, or large appliances maybe cleaned and saved.Low Value – High Contact ItemsE.G., clothing, plastic toys and toothbrushshould always be discarded.(See exceptions in text.)Low Value – Low Contact ItemsE.G., A How To Report Meth Labs screw driver, garden rake or other metal orhard material item may be cleaned in some circumstances.
 
Household contents and guidance for their disposition are listed below. This list is not exhaustive.Recommendations for household How To Report Meth Labs contents are divided into three categories:1) Always Discard, 2) Disposal Strongly Recommended and 3) Disposal Recommended. Infants’ and Small Children’s Clothes, Toys, Furniture and Personal Items:Always Discard.
 
Exceptions: Metal or other hard medical devices such as glasses or orthopedic devices that canbe cleaned may be exempted in consultation with the contractor regarding decontamination How To Report Meth Labs options. Other Fabric Goods:Disposal Strongly Recommendedwater. Any item that shows evidence of use for meth cooking (e.g. acid etching, chemicalstaining) must be discarded.

How Do I Encapsulate And Dehumidify The Crawl Spac

This Guide for Home Energy Raters presents Guide Details that serve as a visual reference for each of the line items in the Water Management System Builder Checklist. Crawl Space Drying How Do I Encapsulate And Dehumidify The Crawl Spac The details are great tools for Rater education and will help Raters answer contractor and subcontractor questions.&nb  read more..

How To Remove Black Mold From Moldings

If mold is a problem in your home, clean up the mold and get rid of the excess water or moisture. Fix leaky plumbing or other sources of water. Wash mold off hard surfaces with detergent and water, Mold Remediation How To Remove Black Mold From Moldings and dry completely. Absorbent materials (such as ceiling tiles & carpet) that becom  read more..

Asbestos Insulation

Asbestos insulation in Vermiculite Insulation Some residential vermiculite insulation may contain asbestos insulation. What is asbestos insulation? Asbestos insulation is a mineral fiber. Asbestos insulation fibers are long, thin, and very strong, Asbestos Abatement Asbestos Insulation yet flexible enough to be woven toget  read more..

Effects Of Smoke On Electronic Equipment

In the United States, flammability requirements for electrical equipment are most commonly specified in the National Electrical Code (NEC) [12]. Specific testing requirements are then defined by testing laboratory standards (e.g., Underwriters Laboratories, Canadian Standards Association, etc.). Suc  read more..

Fire Damage Electronic Restoration Classes

Some Micro-miniature and Nano-miniature type connectors have the option of pre-terminated cross linked ETFE (TefzelTM) insulated wire pigtails. Users are advised that some ETFE insulations are known to out-gas trace amounts of corrosive fluorine over time. When this wire is used with nickel coated m  read more..

Withstanding Wind And Lightning

Rooftop Attachment of Lightning Protection Systems in High-Wind Regions Hurricane Katrina Recovery AdvisoryFEMA May 2006, Revised July 2006 Purpose: To recommend practices for installing lightning protection systems (LPS) that will enhance Wind Damage Withstanding Wind And Lightning wind resistance in high-wind regions. Key Iss  read more..

Do It Yourself Restoration Of Mold Damage On Paper

Although it is neither necessary nor desirable to remove all dirt or discoloration from old papers, surface cleaning sometimes improves the appearance of an artifact. Surface cleaning can also remove substances that might eventually damage paper, or that could be transferred to other papers during h  read more..

How To Stop A Basement Water Leak Waterproofing

The hydrologic cycle is the continuous circulation of water from land and sea to the atmosphere and back again : water evaporates from oceans, lakes, and rivers into the atmosphere. This water later precipitates as rain or snow onto the land where it evaporates or runs off into streams and rive  read more..

Ceiling Leak Repair Cost

If the water level was less than 2½ feet, the wall material should be removed to a height of 4 feet to facilitate reinstallation of full sheets of drywall. If the water level was greater than 2½ feet, the wall material should be removed to a height of 8 feet or the ceiling junction, whichever is h  read more..

Mold Poisonng Symptoms

Four Steps for Responding to Mold Problems 1. Respond quickly with appropriate actions to stop water damage and limit potential exposure to occupants 2. Identify: The cause of the moisture problem The extent of contamination The safety precautions for remediation 3. Implement remediation Remove   read more..