Meth Lab Cleanup >> Meth Manufacturing Labs

Once decontamination is completed, the certified contractor must perform the post-decontaminationsampling to determine compliance with the decontamination standard. It is also the responsibility of thecertified contractor to arrange for disposal of all waste materials, Meth Manufacturing Labs inspect the dumpster, truck, roll-off boxor other container of structure contents and waste prior to the waste leaving the site. Inspection is doneto ensure that no hazardous chemicals, containers of anhydrous ammonia, or biohazards (sharps, etc.)are improperly disposed.
 
The certified contractor must also ensure that all furniture, clothing, carpeting,and other items disposed have been destroyed Meth Manufacturing Labs or rendered unusable to prevent scavenging of theseitems. All wastes must be disposed of in accordance with state and federal EPA and DOT regulations.A Contractor’s Certificate of Decontamination (CCD) must be submitted to the Kentucky Division ofWaste Management by the certified contractor within sixty (60) days after decontamination services areperformed on a property.
 
 The CCD report, documents the assessment, decontamination, actions taken ata site, and chemical screening results. Electronic Meth Manufacturing Labs version can be requested from KDWM.KDWM reserves the right to conduct oversight, either with its own staff or a qualified contractor,of the meth lab decontamination activities performed by the certified contractor and to collect itsown post-decontamination samples to verify that the decontamination standard was met.
 
The certified contractor and the property owner shall retain all records related to the decontamination ofthe inhabitable property for a period of at least five (5) years after the CCD has been issued. Thisincludes the CCD, preliminary assessment findings, all data and laboratory Meth Manufacturing Labs analytical results of the postdecontamination sampling and quality assurance/quality control records, and field sampling logs.B. Lab Site EntryOnce notified by the local health department, law enforcement shall post signs on the exterior doors ofthe property with Notice of Meth Contamination signs warning of possible chemical contamination.
 
 The notice will remain on the property until it has been decontaminated by a certified contractor in accordancewith the law and this guidance document.Before entering the site, the certified contractor shall carefully consider the hazard potential fromexposure to chemical residues, confined spaces or other physical hazards, and proper Meth Manufacturing Labs personal protective equipment (PPE) to perform the decontamination. It is the contractor’s responsibility to ensurethat all personnel under their supervision have the necessary safety equipment and that their workactivities are conducted safely in accordance with KyOSH regulations in 803 KAR 2:403, and 29 CFR1926.50 to 1926.65, the construction industry standard and the federal HAZWOPER regulations forGeneral Site Worker.
 
 Keep in mind many of the spaces that shall require entry and cleaning could meetthe definition of a Confined Space per 803 Meth Manufacturing Labs KAR 2:200, and may require specialized training. The certified contractor shall always wear the appropriate personal protective equipment (PPE) includingrespiratory protection if needed, based on site conditions and air monitoring data, and based on the typeof work they are performing.
 
Monitoring/sampling equipment should include, but not be limited to:
• A photo-ionization detector (PID), flame ionization detector (FID) or similar device to check for thepresence of organic vapors in the air. The instrument must be properly calibrated and maintained,
• pH paper,
• De-ionized water,
• Camera (for documentation),
• Ruler and masking tape or pre-fabricated 10 cm by Meth Manufacturing Labs 10 cm template,
• Sample collection supplies including gauze pads, methanol, sample containers and cooler.
 
One hazard that shall not be overlooked when assessing or decontaminating a meth lab is hypodermicneedles. Needles can sometimes be mixed in with the trash and other wastes Meth Manufacturing Labs and can be found infurniture or intentionally hidden in unexpected places. The potential for transmission of blood-bornepathogens including HIV/AIDS or hepatitis through needle "sticks” can be a significant hazard for siteswhere "users” were present. Because of the possibility that the needles can penetrate personal protectiveequipment (PPE), extra caution should be taken by the certified contractor and their staff.
 
 Also, somelabs may have "booby traps” in place to make it difficult for law enforcement or others to access parts ofthe property. Caution should be taken when entering or investigating any Meth Manufacturing Labs former meth lab property.C. Preliminary AssessmentThe certified contractor shall conduct a preliminary assessment of the property and all structures onthe property. This information will be critical to how the property should be effectively and safely decontaminated.
 
Pre-decontamination sampling is not required, but samples may be collected ofsuspected cooking areas, spills or stained Meth Manufacturing Labs locations, waste disposal areas, HVAC system, plumbingfixtures, and other locations to determine the most effective plan for decontamination of the property.Once the property is decontaminated, post-decontamination samples are required.
 
The following shallbe collected and documented in the Contractor’s Certificate of Decontamination (CCD), DEP 5035,January 2009:
• Obtain copy of the KDWM Clandestine Drug Lab Meth Manufacturing Labs Preliminary Assessment Tier Selection Criteria,DEP 1016, January 2009 available by open records request to KDWM.
• Property description (i.e., physical address, latitude and longitude, legal description, physicallayout of the property, structural features, etc.)
• Photographic documentation of site
• During the initial walk-through the certified contractor shall note hazardous chemical use orstorage areas, waste disposal areas, cooking areas, chemical stains, fire damage, and otherobservable damage.
 
 
• Information about surfaces, furnishings, appliances, and other Meth Manufacturing Labs features
• Inspection of HVAC system
• Inspection of plumbing, septic system, sewer system
• Inspection of garages, barns, and other outbuildings on the property
• Identification of adjacent areas/units in multiple dwellings that may require cleaning
• Identification and documentation of areas of contamination
• Outdoor inspection for evidence of burn or trash pits, discolored soil, or dead vegetation,indicating possible contamination of water and/or soil.
 
 Site-Type Considerations
The layout of the lab, its structural characteristics and potential future use shall be considered whendesigning a decontamination plan. Lab sites may be loosely categorized as follows:
• Private occupancy structure, e.g., single family home and attached garage, apartment ormultiple dwelling
• Mobile residence, e.g., motor home, camper or manufactured Meth Manufacturing Labs home
• Non-occupancy structure, e.g., detached garage, barn, tool shed, etc.8) Articles of clothing and toys have the potential to be heavily contaminated withcontaminants of concern (COC), therefore they shall not be reused.
 
KDWM recommends that the certified contractor remove any clothing, children’s toysor other items left behind by the meth lab operator or their families, render themunusable, properly dispose of them, Meth Manufacturing Labs and provide disposal receipts. This step shall bephoto documented. Since removal and replacement of appliances is not anticipatedwith a Tier 1 Response, wash and clean all appliances thoroughly. For evaluatingpersonal items and contents of the structure, see Section L of this guidance.9) Please note all contaminated properties shall require at least a Tier 1 cleanupresponse.

Remove The Smoke Smell From Clothes After A House

The National Institute for Occupational Safety and Health (NIOSH) warns workers and volunteers of the potential dangers involved with cleanup operations following the devastation caused by forest fires. Because the level of experience varies among these workers, cleanup crews must work together and&  read more..

Professional Water Damage Carpet Cleaning

In the wake of Hurricane Isaac's recent recovery efforts, Louisiana's restoration from Hurricane Rita persists, enabled by approximately$1.3 billion in Federal Emergency Management Agency public assistance, hazard mitigation Water Extraction Professional Water Damage Carpet Cleaning and individual assistance funding since her landfall on Sept  read more..

Roof Leak Detection

Moldy surfaces should be cleaned first and then disinfected; some products do both in a single step. In all cases, mold spores should be removed as completely as possible since killing them does not eliminate their toxicity or allergenic properties.Application of Cleaners are most efficiently a  read more..

House Fire Exposure To Smoke

"Mask" means different things to different people. For example, to some people "dust mask" describes a P100 particulate respirator used in the construction industry, Smoke Damage House Fire Exposure To Smoke and to others it means a one-strap paper mask that is NOT a respirator. A disposable particulate respirator has been ce  read more..

Natural Repellents

Some people like to spend a lot of time and maybe a lot of money on their garden. But it can be frustrating when raccoons, rabbits, deer and other animal damage is destroying your garden. Animal control repellents might work, but they also might damage your plants. There are a number of natur  read more..

Flash Floods Mold And Mildew

Following a widespread flooding disaster, many questions arise from citizens within the communities affected and from the many volunteers and Flood Damage Flash Floods Mold And Mildew organizations that are working in the devastated area. Personal health and safety is a priority for everyone.

The following information i  read more..

How To Restore Fire Damaged Photos

When reviewing completed work, keep in mind that it is difficult to evaluate technical aspects of a treatment. A good rule of thumb is that all repairs should be discernable to a trained eye, Document restoration How To Restore Fire Damaged Photos  o that those consulting the materials in the future will not be misled about an item's   read more..

How To Clean An Electronic Circuit Board After It

In comparison with semiconductor devices, MnO2-based tantalum capacitors are generally considered to be insensitive to radiation. Small shifts of roughly 10 mV/krad (Si) are observed in the open-circuit voltage of previously discharged capacitors, but this effect is transient and generally only of i  read more..

Asbestosis

Abstract Asbestosis is defined as diffuse pulmonary fibrosis caused by the inhalation of excessive amounts of asbestos fibers. Pathologically, Asbestos Abatement Asbestosis both pulmonary fibrosis  read more..

Contracting FEMA For Debris Removal

A subgrant will be prepared at the appropriate cost share to reflect the amount of debris removal work completed during each operational time frame. If the Subgrantee agrees to this alternative procedure, no costs associated with debris removal that occur after 180 days from the start ofthe inc  read more..