Meth Lab Cleanup >> OSHA Requirements For Meth Lab Cleanup

The decontamination standard set by Kentucky’s meth cleanup law is 0.1 micrograms of meth per100 square centimeters (0.1 ug/100 cm2) of surface materials. See Section V. InteriorDecontamination Procedures for the decontamination procedures for each tiered cleanup response.When states originally established cleanup standards for meth, due OSHA Requirements For Meth Lab Cleanup to lack of health effects informationand toxicity data, they were based primarily on the lowest level an analytical laboratory could reliablyachieve. Many states currently use a cleanup standard ranging from 0.05 to 0.5 micrograms ofmethamphetamine per one hundred square centimeters (ug/100 cm2) for meth in surface wipe samples.
 
However, a 2005 study by the Colorado Department for Public Health and the Environment found that thecleanup standards used OSHA Requirements For Meth Lab Cleanup by several states including Kentucky are protective of human health based onexpected child and adult exposure. Furthermore, research from the State of Minnesota has shown that sampling for meth may not be areliable measure of the entire volume of meth in a structure. Therefore, this guidance focuses heavilyon a decontamination process that is practical and can be implemented coupled with thecollection of post-decontamination samples to confirm that the standard has been achieved.
 
The goal of the overall cleanup process is to reduce risk to future occupants by reducing exposure tocontamination, through a combination of cleaning, disposal, decontamination and OSHA Requirements For Meth Lab Cleanup encapsulation activitiesdescribed in this guidance.All contaminated properties that have been posted by the health department or law enforcementshall undergo decontamination actions based on the tiered response level that has been recommendedfor the property by law enforcement in the Clandestine Drug Lab Preliminary Assessment Tier SelectionCriteria, DEP 1016 January 2009.
 
 This is further discussed in Section V. Interior Decontamination.This guidance is based on the presumption that all rooms and all structures on a meth manufacturer’s property are considered potentially contaminated. Therefore, these are the standards set forth by this OSHA Requirements For Meth Lab Cleanup guidance:
• All inhabitable properties containing a meth lab or chemicals shall be decontaminated followingthe procedures in this guidance.
• All non-occupied structures on a property where meth labs or chemicals are found shall beinspected. They shall be decontaminated if necessary. This includes outbuildings, detachedgarages, and sheds. These structures are likely locations of storage of chemicals and finished products.
 
III. CHEMICAL SAMPLING/DECONTAMINATION STANDARDS
A. Meth Wipe Sampling(See Appendix B.1. for sampling procedures)Meth wipe samples are typically collected by wiping a wall or other hard surface with a solventdampened wipe. Gauze pads, sponges or filter paper wetted with methanol are often used for surfacewipes. For many OSHA Requirements For Meth Lab Cleanup building materials, the amount of meth removed by wipe collection from the surface is asmall fraction of the total amount of meth present in the building material due to the material’s surfacetexture and porosity.
 
Meth wipe samples may be taken as part of the Preliminary Assessment conductedby the certified contractor to help determine site conditions before decontamination and to possibly helpin guiding cleanup efforts. However, wipe samples of the surfaces most likely to be contaminated,shall be taken following decontamination activities to demonstrate compliance with thedecontamination standard of 0.1 ug meth per 100 square centimeters (0.1 ug/100 cm2). SeeAppendix B.1 for required procedures for wipe sampling and OSHA Requirements For Meth Lab Cleanup refer to Section VI. Post-DecontaminationSampling of this guidance for specific meth sampling locations, and analytical requirements.
 
Several meth wipe sampling kits are available by a OSHA Requirements For Meth Lab Cleanup number of vendors, and are useful in screening areas todetermine if additional decontamination may be necessary or if one should collect quantitative wipesamples to meet the standard. However, results from wipe sample kits cannot be used for finalpost-decontamination sampling to meet the decontamination standard. Decontamination StandardsIndoor chemical-specific testing and screening recommendations and requirements are listed in Table 1below and described further in the following text.
 
 All areas tested must be photographed to document thelocation of the sampled area. Chemical screening shall be OSHA Requirements For Meth Lab Cleanup conducted during the assessment anddecontamination.Table 1: Decontamination StandardsChemical Decontamination Standard**Methamphetamine 0.1 µg/ 100 cm2(all surface materials)Corrosives(Acids/Bases) pH 6-8Volatile Compounds < 1 ppm total volatiles in air (PID or FID)Lead* Contact KDWM for standards and sampling requirementsMercury* Contact KDWM for standards and sampling requirements*Testing for lead and mercury may only be necessary for P2P (Amalgam) labs.**Testing that is required for all discovered meth labs.
 
Corrosives: Commonly used corrosives include but are not limited to Hydrochloric Acid, Sulfuric Acid,Sodium Hydroxide, Anhydrous Ammonia, Phosphoric Acid and Muriatic Acid. Surface pH testing duringthe assessment and decontamination process may be conducted. See Appendix B.2 for requiredsampling procedure.Volatile Chemicals (VOCs): Commonly used VOCs (solvents) include but are not limited to Acetone,Benzene, Ether, Freon, Hexane, Isopropanol, Methanol, OSHA Requirements For Meth Lab Cleanup Toluene and Xylene. Ammonia also is a volatileinorganic compound that can be detected through screening.
 
 VOC screening should be conducted in allrooms of OSHA Requirements For Meth Lab Cleanup the structure, for the safety of workers as well as for assessment purposes and to verifydecontamination. VOC screening can also be used to detect sources of residual organic vaporcontamination, such as in heating vents, plumbing and sewers. See Appendix B.2 for required samplingprocedurePhosphorus and Iodine: Removal of stained materials is the best means of remediating contaminationinvolving red phosphorus, iodine crystals, and tincture of iodine. Spray starch can be used as a screenfor the presence of iodine residues.
 
 When removal of stained material is not a reasonable option (such ason a concrete floor), the surface can be power-washed, allowed to dry, and then sealed.Mercury and Lead: P2P (Amalgam) meth labs involve the use of lead acetate and mercuric chloride.Typically, the processes (methods using phenyl-2-propanine (P2P) precursor) that used lead andmercuric compounds have been abandoned in favor of simpler methods using lithium or sodium metal, orred phosphorus and OSHA Requirements For Meth Lab Cleanup iodine. Decontamination of an inhabitable property in Kentucky shall be completed by a contractor certified bythe Energy and Environment Cabinet.
 
 The certified contractor shall conduct meth lab assessment,sampling and decontamination using the procedures of this guidance, and in accordance with KRS224.01-410. In addition to OSHA Requirements For Meth Lab Cleanup other requirements, the certified contractor is required to attend KyOSHrequired HAZWOPER safety training. A number of states including Tennessee and Indiana, as well asprivate vendors offer meth lab cleanup training that would be beneficial in developing an understanding ofthe issues affecting meth lab sites and decontamination. See KDWM’s webpage for links to other states’ programs for information on upcoming training classes.

FEMA Flood Maps

What is a Conditional Letter of Map Revision (CLOMR)? A Conditional Letter of Map Revision (CLOMR) is FEM's formal review and comment on whether a proposed project complies with the minimum NFIP FEMA flood maps management criteria. NFIP maps are based on existing, rather than proposed, Flood Damage FEMA Flood Maps&nbs  read more..

Tsunamis

Tsunamis Tsunamis (pronounced soo-n¡-mees), also known as seismic sea waves (mistakenly called "tidal waves"), are a series of enormous waves created by an underwater disturbance such as an earthquake, landslide, volcanic eruption, Flood Damage Tsunamis or meteorite.

A tsunami can move hundreds of m  read more..

How To Clean Smoke Damage From Walls And Fixtures

The total amount of a given species released by a fire is thus dependent on the fuel consumed.This is most typically specified as a user input based on a combination of the burning object's heat release rate, mass loss rate, and heat of combustion (Hc) related as ܳ. The discussion above is ess  read more..

How To Secure Windows For A Hurricane

To prepare for a hurricane, you should take the following measures: To begin preparing, you should build an emergency kit and make a family communications plan. Know your surroundings. Learn the elevation level of your property and whether the land is flood-prone. This will help you know how your pr  read more..

How To Clean Fire Smoke Damage

Tips on how to handle the fire damage There are companies that are experts in cleaning and/or restoring your personal items.Whether you or your insurer buys this type of fire service, Fire Damage How To Clean Fire Smoke Damage be clear on who will pay for it. 

Be sure to ask for an estimate of cost for t  read more..

How To Dehumidify A Flooded Crawl Space

Intuitively, reheating a cooled air stream using hot discharge gas from a refrigerant compressor makes sense. However, it mitigates only the last of the four penalties of ordinary reheat systems mentioned in the sidebar. The refrigeration plant still must be larger by the amount of reheat. Also, the  read more..

Basement Flood Cleanup

When returning to your home after a hurricane or flood, be aware that flood water may contain sewage. Protect yourself and your family by following these steps:Inside the Home Keep children and pets out of the affected area until cleanup has been completed. Wear rubber boots, rubber gloves, and Water Damage Basement Flood Cleanup  read more..

How To Select The Right Size Of Dehumidifier

During the humidification process, organics will evaporate accompanying the water evaporation, forming an organic-containing humidified air. Generally, Dehumidification How To Select The Right Size Of Dehumidifier the organic concentration in humidified air is far below the saturation, particularly for the volatile organics. The subsequent cooli  read more..

Clean Smoke Damage From Walls And Fixtures After A

The U.S. Department of Homeland Security (DHS) today adopted five NFPA (National Fire Protection Association) Fire Damage Clean Smoke Damage From Walls And Fixtures After A standards for personal protective equipment for first responders. These adoptions will assist state and local procurement officials in selecting the best available protective equipment.  read more..

Storm And High Flood Damage Prevention Plan

Mold, mildew and bacteria are common following floods and other water damage. If unchecked they can lead to sanitation and health problems. The walls, floors, closets, shelves, contents-every flooded part of your house-should be thoroughly washed and disinfected.In most cases, Flood Damage Storm And High Flood Damage Prevention Plan household cleanin  read more..