Meth Lab Cleanup >> OSHA Requirements For Meth Lab Cleanup

The decontamination standard set by Kentucky’s meth cleanup law is 0.1 micrograms of meth per100 square centimeters (0.1 ug/100 cm2) of surface materials. See Section V. InteriorDecontamination Procedures for the decontamination procedures for each tiered cleanup response.When states originally established cleanup standards for meth, due OSHA Requirements For Meth Lab Cleanup to lack of health effects informationand toxicity data, they were based primarily on the lowest level an analytical laboratory could reliablyachieve. Many states currently use a cleanup standard ranging from 0.05 to 0.5 micrograms ofmethamphetamine per one hundred square centimeters (ug/100 cm2) for meth in surface wipe samples.
 
However, a 2005 study by the Colorado Department for Public Health and the Environment found that thecleanup standards used OSHA Requirements For Meth Lab Cleanup by several states including Kentucky are protective of human health based onexpected child and adult exposure. Furthermore, research from the State of Minnesota has shown that sampling for meth may not be areliable measure of the entire volume of meth in a structure. Therefore, this guidance focuses heavilyon a decontamination process that is practical and can be implemented coupled with thecollection of post-decontamination samples to confirm that the standard has been achieved.
 
The goal of the overall cleanup process is to reduce risk to future occupants by reducing exposure tocontamination, through a combination of cleaning, disposal, decontamination and OSHA Requirements For Meth Lab Cleanup encapsulation activitiesdescribed in this guidance.All contaminated properties that have been posted by the health department or law enforcementshall undergo decontamination actions based on the tiered response level that has been recommendedfor the property by law enforcement in the Clandestine Drug Lab Preliminary Assessment Tier SelectionCriteria, DEP 1016 January 2009.
 
 This is further discussed in Section V. Interior Decontamination.This guidance is based on the presumption that all rooms and all structures on a meth manufacturer’s property are considered potentially contaminated. Therefore, these are the standards set forth by this OSHA Requirements For Meth Lab Cleanup guidance:
• All inhabitable properties containing a meth lab or chemicals shall be decontaminated followingthe procedures in this guidance.
• All non-occupied structures on a property where meth labs or chemicals are found shall beinspected. They shall be decontaminated if necessary. This includes outbuildings, detachedgarages, and sheds. These structures are likely locations of storage of chemicals and finished products.
 
III. CHEMICAL SAMPLING/DECONTAMINATION STANDARDS
A. Meth Wipe Sampling(See Appendix B.1. for sampling procedures)Meth wipe samples are typically collected by wiping a wall or other hard surface with a solventdampened wipe. Gauze pads, sponges or filter paper wetted with methanol are often used for surfacewipes. For many OSHA Requirements For Meth Lab Cleanup building materials, the amount of meth removed by wipe collection from the surface is asmall fraction of the total amount of meth present in the building material due to the material’s surfacetexture and porosity.
 
Meth wipe samples may be taken as part of the Preliminary Assessment conductedby the certified contractor to help determine site conditions before decontamination and to possibly helpin guiding cleanup efforts. However, wipe samples of the surfaces most likely to be contaminated,shall be taken following decontamination activities to demonstrate compliance with thedecontamination standard of 0.1 ug meth per 100 square centimeters (0.1 ug/100 cm2). SeeAppendix B.1 for required procedures for wipe sampling and OSHA Requirements For Meth Lab Cleanup refer to Section VI. Post-DecontaminationSampling of this guidance for specific meth sampling locations, and analytical requirements.
 
Several meth wipe sampling kits are available by a OSHA Requirements For Meth Lab Cleanup number of vendors, and are useful in screening areas todetermine if additional decontamination may be necessary or if one should collect quantitative wipesamples to meet the standard. However, results from wipe sample kits cannot be used for finalpost-decontamination sampling to meet the decontamination standard. Decontamination StandardsIndoor chemical-specific testing and screening recommendations and requirements are listed in Table 1below and described further in the following text.
 
 All areas tested must be photographed to document thelocation of the sampled area. Chemical screening shall be OSHA Requirements For Meth Lab Cleanup conducted during the assessment anddecontamination.Table 1: Decontamination StandardsChemical Decontamination Standard**Methamphetamine 0.1 µg/ 100 cm2(all surface materials)Corrosives(Acids/Bases) pH 6-8Volatile Compounds < 1 ppm total volatiles in air (PID or FID)Lead* Contact KDWM for standards and sampling requirementsMercury* Contact KDWM for standards and sampling requirements*Testing for lead and mercury may only be necessary for P2P (Amalgam) labs.**Testing that is required for all discovered meth labs.
 
Corrosives: Commonly used corrosives include but are not limited to Hydrochloric Acid, Sulfuric Acid,Sodium Hydroxide, Anhydrous Ammonia, Phosphoric Acid and Muriatic Acid. Surface pH testing duringthe assessment and decontamination process may be conducted. See Appendix B.2 for requiredsampling procedure.Volatile Chemicals (VOCs): Commonly used VOCs (solvents) include but are not limited to Acetone,Benzene, Ether, Freon, Hexane, Isopropanol, Methanol, OSHA Requirements For Meth Lab Cleanup Toluene and Xylene. Ammonia also is a volatileinorganic compound that can be detected through screening.
 
 VOC screening should be conducted in allrooms of OSHA Requirements For Meth Lab Cleanup the structure, for the safety of workers as well as for assessment purposes and to verifydecontamination. VOC screening can also be used to detect sources of residual organic vaporcontamination, such as in heating vents, plumbing and sewers. See Appendix B.2 for required samplingprocedurePhosphorus and Iodine: Removal of stained materials is the best means of remediating contaminationinvolving red phosphorus, iodine crystals, and tincture of iodine. Spray starch can be used as a screenfor the presence of iodine residues.
 
 When removal of stained material is not a reasonable option (such ason a concrete floor), the surface can be power-washed, allowed to dry, and then sealed.Mercury and Lead: P2P (Amalgam) meth labs involve the use of lead acetate and mercuric chloride.Typically, the processes (methods using phenyl-2-propanine (P2P) precursor) that used lead andmercuric compounds have been abandoned in favor of simpler methods using lithium or sodium metal, orred phosphorus and OSHA Requirements For Meth Lab Cleanup iodine. Decontamination of an inhabitable property in Kentucky shall be completed by a contractor certified bythe Energy and Environment Cabinet.
 
 The certified contractor shall conduct meth lab assessment,sampling and decontamination using the procedures of this guidance, and in accordance with KRS224.01-410. In addition to OSHA Requirements For Meth Lab Cleanup other requirements, the certified contractor is required to attend KyOSHrequired HAZWOPER safety training. A number of states including Tennessee and Indiana, as well asprivate vendors offer meth lab cleanup training that would be beneficial in developing an understanding ofthe issues affecting meth lab sites and decontamination. See KDWM’s webpage for links to other states’ programs for information on upcoming training classes.

Symptoms Of Black Mold Removal

If you have an allergy that never ends when seasons change, you may be allergic to the spores of molds or other fungi. Molds live everywhere, and disturbing a mold source can disperse the spores into the air. What Is Mold Allergy? Mold and mildew are fungi. They differ from plants or animals in  read more..

Black Mold Removal

Coccidioidomycosis is caused by Coccidioides immitis, a dimorphic fungus that grows as a mold in the soil. The mold forms arthroconidia within the hypha, a type of conidia formation known as enteroarthric development (Figure 1) (4). C. immitis is the only species within the primary pathogenic fungi   read more..

Trauma Cleanup

The following information is a service to the public when you are confronted with the unfortunate situation of cleaning up some kind of crime scene in your home or business. This article can provide you with guidance for a biological Crime Scene Cleanup Trauma Cleanup but the reader should also be aware that some crime sc  read more..

Frozen Pipe Cost

Household Plumbing TipsThe City of Phoenix Water Services Department has almost 7,000 miles of water mains throughout the city.Phoenix Water Services is responsible for repairing all leaks, broken pipes, and water mains on the city, or Water Damage Frozen Pipe Cost street side of the water meters. 

  read more..

Derechos Tornadoes And Cyclones X

The rain produced by the newer storms reinforces the cold pool, strengthening the inflow of air from the back side of the developing storm complex and encouraging the downward transport of higher momentum air from aloft. These processes can enable the system Wind Damage Derechos Tornadoes And Cyclones X to attain a nearly steady-  read more..

Mold Tester Certification

There is substantial visible mold growth inside hard surface (e.g., sheet metal) ducts or on other components of your heating and cooling system. There are several important points to understand concerning mold detection in heating and cooling systems: Many sections of your heating and cooling syste  read more..

Do It Yourself Mold Mitigation

If abatement procedures are expected to generate a lot of dust (e.g., abrasive cleaning of contaminated surfaces, demolition of plaster walls) or the visible concentration of the mold is heavy (blanket coverage as opposed to patchy), Mold Remediation Do It Yourself Mold Mitigation it is recommended that the remediation procedures for Le  read more..

Water Damage Carpet Cleaning Hints

There is a lot of misinformation circulating on social networks regarding the response and recovery effort for Hurricane Sandy. Rumors spread fast: please tell a friend, share this page and help us provide accurate information about the types of assistance available.Check here often for an on-going   read more..

Water Lead Test

If your residence was built prior to 1978, have your residence tested for Lead Paint Removal Water Lead Test and learn about potential lead dangers. Fix any dangers that you might have. You could get your residence checked for in one or both of the following methods: 

A house paint inspection — this tell  read more..

Radon Mitigation

One of the more efficient ways to provide a drying mechanism to a Crawl Space Drying Radon Mitigation is to condition a crawl space by the use of heating and cooling and the crawl space as if the crawl space is just another part of the home. Crawl spaces need to always have a good ground cover that will prevent evaporation   read more..