Basement Drying >> Safely Get Water Out Of A Flooded Basement

Reinforce walls and footings to minimize shrinkage cracking and cracking due to uneven settlement. To retard movement of radon through hollow core masonry walls, the top and bottom courses of hollow masonry walls should be solid block, Safely Get Water Out Of A Flooded Basement or filled solid. 

If the top side of the bottom course is below the level of the slab, the course of block at the intersection of the bottom of the slab should be filled. Where a brick veneer or other masonry ledge is installed, the course immediately below that ledge should also be solid block. Safely Get Water Out Of A Flooded Basement Parge and seal the exterior face of below-grade concrete masonry walls in contact with the soil. 

Install drainage boards to provide an airway for soil gas to reach the surface outside the wall rather than being drawn through the wall. Safely Get Water Out Of A Flooded Basement Install a continuous damp proofing or waterproofing membrane on the exterior of the wall. Six-mil polyethylene-lapped, taped and placed on the exterior of the basement wall surface will retard radon entry through wall cracks. 

Seal around plumbing and other utility and service penetrations through the wall with polyurethane or similar caulking. Safely Get Water Out Of A Flooded Basement Both the exterior and the interior of concrete masonry walls should be sealed at penetrations. Install airtight seals on doors and other openings between a basement and adjoining crawl space. 

Seal around ducts, plumbing, and other service connections between a basement and a crawl space. Safely Get Water Out Of A Flooded Basement Do not place air supply or return ducts under the slab or in the footing. Intercepting Soil Gas. The most effective way to limit radon and other soil gas entry is through the use of active soil depressurization (ASD). 

ASD works by lowering the air pressure in the soil relative to the indoors. Safely Get Water Out Of A Flooded Basement Avoiding foundation openings to the soil, or sealing those openings, as well as limiting sources of indoor depressurization aid ASD systems. Sometimes a passive soil depressurization (PSD, with no fan) system is used. 

If post-occupancy radon testing indicates further radon reduction is desirable, a fan can be installed in the vent pipe (see Figure 2-10). Safely Get Water Out Of A Flooded Basement Subslab depressurization has proven to be an effective technique for reducing radon concentrations to acceptable levels, even in homesSafely Get Water Out Of A Flooded Basement  with extremely high concentrations (Dudney 1988). 

This technique lowers the pressure around the foundation envelope, causing the soil gas to be routed into a collection system, avoiding the inside spaces and discharging to the outdoors. Safely Get Water Out Of A Flooded Basement A foundation with good subsurface drainage already has a collection system. The under slab gravel drainage layer can be used to collect soil gas. 

It should be at least 4 inches thick, and of clean aggregate no less than 1/2 inch in diameter. Safely Get Water Out Of A Flooded Basement The gravel should be covered with a 6-mil polyethylene radon and moisture retarder. A 3- or 4-inch diameter PVC vent pipe should be routed from sub slab gravel layer through the conditioned portion of the building and through the highest roof plane. 

The pipe should terminate below the slab with a "tee” fitting. Safely Get Water Out Of A Flooded Basement To prevent clogging the pipe with gravel, ten-foot lengths of perforated drain tile can be attached to the legs of the tee, and sealed at the ends. Alternately, the vent pipe can be connected to the perimeter drain system, as long as that system does not connect to the outdoor environment. 

Horizontal vent pipes could connect the vent stack through below grade walls to permeable areas beneath adjoining slabs. Safely Get Water Out Of A Flooded Basement A single vent pipe is adequate for most houses with less than 2,500 square feet of slab area that also include a permeable subslab layer. The vent pipe is routed to the roof through plumbing chases, interior walls, or closets. 

A PSD system requires the floor slab to be nearly airtight so that collection efforts are not short-circuited by drawing excessive room air down through the slab and into the system. Safely Get Water Out Of A Flooded Basement Cracks, slab penetrations, and control joints must be sealed. Sump hole covers should be designed and installed to be airtight. 

Floor drains that discharge to the gravel beneath the slab should be avoided, but when used, should be fitted with a mechanical trap capable of providing an airtight seal. Safely Get Water Out Of A Flooded Basement Another potential short circuit can occur if the subdrainage system has a gravity discharge to an underground outfall. This discharge line may need to be provided with a mechanical seal. 

The subsurface drainage discharge line, if not run into a sealed sump, should be constructed with a solid-glued drainpipe that runs to daylight. Safely Get Water Out Of A Flooded Basement The standpipe should be located on the opposite side from this drainage discharge. 

While a properly installed passive soil depressurization (PSD) system may reduce indoor radon concentrations by about 50%, active soil depressurization (ASD) systems can reduce indoor radon concentrations by up to 99%. Safely Get Water Out Of A Flooded Basement A PSD system is more limited in terms of vent pipe routing options, and is less forgiving of construction defects than ASD systems. 

Furthermore, in new construction, small ASD fans (25-40 watt) may be used with minimal energy impact. Active systems use quiet, in-line duct fans to draw gas from the soil. Safely Get Water Out Of A Flooded Basement The fan should be located outside, and ideally above, the conditioned space so that any air leaks from the positive pressure side of the fan or vent stack are not in the living space. 

The fan should be oriented to prevent accumulation of condensed water in the fan housing. Safely Get Water Out Of A Flooded Basement The ASD stack should be routed up through the building or an attached garage or carport, and extend twelve inches above the roof. It can also be carried out through the band joist and up along the outside of wall.

To a point high enough so that there is no danger of the exhaust being redirected into the building through attic vents or other pathways. Safely Get Water Out Of A Flooded Basement Because PSD systems rely on natural buoyancy to operate, a PSD stack must be routed through the conditioned portion of the home. 

A fan capable of maintaining 0.2 inch of water suction under installation conditions is adequate for serving subslab collection systems for most houses (Labs 1988). Safely Get Water Out Of A Flooded Basement This is often achieved with a 0.03 hp (25W), 160 cfm centrifugal fan (maximum capacity) capable of drawing up to 1 inch of water before stalling. 

Under field conditions of 0.2 inch of water, such a fan operates at about 80 cfm. Safely Get Water Out Of A Flooded Basement It is possible to test the suction of the subslab system by drilling a small (1/4-inch) hole in areas of the slab remote from the suction point, and measuring the suction through the hole using a micromanometer or inclined manometer. 

The goal of a subslab depressurization system is to create negative air pressure below the slab, relative to the air pressure in the adjacent interior space. Safely Get Water Out Of A Flooded Basement A suction of 5 Pascals is considered satisfactory when the house is placed in a worst-case depressurization condition (i.e., house closed, all exhaust fans and devices operating, and with the HVAC system operating with interior doors shut). 

The hole must be sealed after the test. PSD systems require near perfection in sealing of openings to the soil, since the system relies on a 3- or 4-inch pipe to vent more effectively than the entire house. Safely Get Water Out Of A Flooded Basement Sealing openings to the soil is less critical for radon control with ASD systems.

Although it is highly desirable in order to limit the energy penalty associated with conditioned indoor air leaking into a depressurized subslab, and from there to the outdoors. Safely Get Water Out Of A Flooded Basement ASD fans have service lives averaging about ten years, with a higher life expectancy if the fan is protected from the elements. Since an ASD system may be turned off by occupants, service switches are usually located in areas with limited access.

Electronic Restoration

Smoke damage can cause considerable damage to your homes electronic equipment and your other appliances. It is very important to take immediate, appropriate action. Your Smoke Damage Electronic Restoration carpets, draperies, upholstered furniture and clothing usually could be refurbished   read more..

What Is Black Mold

Mold problems in buildings are a result of water and moisture problems. Renters need to operate the heating and ventilation systems to reduce water condensation. Renters need to notify landlords promptly, in writing, of any water leaks or moisture problems. If there is a water leak or moisture probl  read more..

Water Damage

A dampness in your home is usually the result from a water incursion either from an internal source, like leaking water pipes or an external sources, such as rainwater due to some kind of storm damage. The intrusion of the dampness becomes a real problem when the various materials in your bui  read more..

How To Remove Soot From A Painted Mantle

The results showed that when conditions were varied, different materials tested as the most corrosive. While all materials tested had a corrosive effect on the targets, there was not a consistent pattern in the reaction of the steel coupons to the test conditions. Enhancing condensation with ice typ  read more..

Hot Water Extration From Carpet

Benchmark locations were integrated with gener­alized maps of soils and geology covering parts ofOrleans Parish, which lies at the center of the NewOrleans MSA. It is important to note that the soil andgeology data sets were digitized from small-scale,paper, photocopied maps to test the initial con  read more..

Smoke Damage

First responders that come across what they suspect to be a working meth lab or who might be responding to an incident need to take extra special precautions before they enter the Meth Lab Cleanup Smoke Damage site. They should never enter the meth lab or touch anything outside the meth lab, like chemical containers   read more..

Enzyme Odor Removal

Reducing Urine-Marking Behavior in Dogs and Cats MUCH LIKE THE MINERS DURING THE GOLD RUSH, dogs and cats are territorial animals. They "stake a claim to a particular space, area, or object. They let other people and animals know about their claim by marking it using a variety of methods at diff  read more..

Electrical Systems In Flood damaged Buildings

Question: Do electrical systems and equipment submerged through flooding have to be replaced? Answer: Floodwaters are not just water; the water may also be contaminated with chemicals, sewage, oil and other debris. When the floodwater is salt water, its corrosive effects are particularly damaging. A  read more..

Radon Abatement

There are many methods that a Radon Mitigation Radon Abatement contractor could use to lower radon levels in your home. Some of these techniques prevent radon from entering your home while others reduce the radon levels after it has entered. The EPA usually recommends the methods which prevent the entry of radon gas, lik  read more..

Tenant Move Out

They moved out and left water damage causing mold If you have a a good lease you will be able to recoup some of your money. However most people do not have a thorough lease so water damage, and damage from mold, basic neglect are not covered in the lease. If you do have a good lease and the tenant f  read more..