Dehumidification >> How Long Should A Dehumidifier Run Per Day

Unit(s) shall be capable and designed for year-round, 24-hours-a-day operation; and requiring only connections of ducts, utilities, and remote sensors, controllers, How Long Should A Dehumidifier Run Per Day and monitors. 3. Unit(s) shall include active regeneration system for control of dehumidification processes. 

Casing: 1. Double-wall construction with corrosion-protective removable panelshinged access doors with neoprene gaskets, minimum 50-mm (2-inch) thick thermal insulation fill, stainless steel fasteners, knockouts for electrical How Long Should A Dehumidifier Run Per Day and piping connections through the side of the unit bottom of the unit without the roof curb, condensate drain connection, and lifting lugs. 

2. The unit housing the internal partitions shall be constructed of minimum 18 gage galvanized steel or aluminum pre-insulated double wall panels with a minimum of 50-mm (2-inch) thermal insulation. The base shall be all welded, structural steel or formed 14-gage, How Long Should A Dehumidifier Run Per Day galvanized steel. Units shall have cross supports for each major component and base channels and lifting eyes to facilitate rigging. 

The units shall be of water and air tight construction over all with interior air tight construction between various sections of the units. Adjoining panels shall be sealed with a silicon compound How Long Should A Dehumidifier Run Per Day or heavy duty compression type gaskets. Leakage rate shall not exceed 2 percent at a pressure of 746 Pa (3.0 inches water gage). 

3. All non-pre-insulated exterior panels shall be insulated with minimum 25-mm (1-inch) vinyl- or foil-faced fiberglass insulation without exposed edges, How Long Should A Dehumidifier Run Per Day and secured by permanent mechanical fasteners. 4. All exterior panels shall be embossed aluminum cabinet panels constructed with corrosion-protective coating on the manufacturer's standard coating. 

5. All internal air-processing and air-treatment components shall be removable through removable access panels without dismantling plenums or ductwork. Access panels shall be provided with resilient gaskets and quick-release hardware. 7. Access doors for filters and control adjustment shall have corrosion-resistant, How Long Should A Dehumidifier Run Per Day continuous hinge or heavy-duty, multiple hinges. 

8. Surfaces in contact with the airstream shall comply with requirements in ASHRAE 62.1-2007. C. Dehumidifier: 1. The dehumidifier shall include a desiccant wheel utilizing a fractional horsepower electric motor and a variable speed drive How Long Should A Dehumidifier Run Per Day and reactivation air flow indicating devices steam hot water electric direct gas fired indirect gas fired reactivation heater reactivation fan/motor assembly, reactivation energy modulation system. 

Electric/mechanical rotation fault circuitry and necessary manual and automatic dampers for proper functioning of the unit under all operating conditions. 2. Dehumidifier shall rotary type, designed for continuous operation, How Long Should A Dehumidifier Run Per Day and arranged to provide a counter flow of process and reactivation air streams with full-face pressure seals or low-friction contact seals on both sides to prevent cross leakage for external static pressure of up to 622 Pa (2.5 inches w.g.) 

3. Desiccant rotor shall have synthesized silica gel, enhanced with titanium, bonded to a ceramic matrix, with filled voids and encapsulating the ceramic. Driver shall be a motor with adjustable drive sheaves and belt-tensioning idler pulley How Long Should A Dehumidifier Run Per Day or adjustable motor mount. 4. The rotary desiccant shall transfer water in the vapor phase. 

The design and geometry shall provide for laminar flow over the operating range for minimum pressure loss with maximum transfer surface How Long Should A Dehumidifier Run Per Day and minimum power requirements. The desiccant shall be a permanent integral part of the structure. 

Heat Exchanger: 1. The heat exchanger shall be constructed of non-hygroscopic material with corrosion protection, described above for the coils and surfaces thermal wheel to prevent the transfer of water vapor or an air-to-air heat pipe with copper tubes and aluminum fins, How Long Should A Dehumidifier Run Per Day fabricated with capillary wick structure charged with ozone friendly refrigerant to be used in the process and reactivation air steams. 

Refrigerant shall comply with ASHRAE 15, Group 1. For thermal wheel, supply How Long Should A Dehumidifier Run Per Day and cooling air streams shall be counter flow and the component provided with full face contact seals on both sides to prevent leakage. The heat transfer effectiveness of the heat exchanger shall be minimum 80 percent with a maximum air pressure loss of 125 Pa (0.50 inch w.g.) 

2. Electric motor shall be fractional-horsepower with close-coupled speed reducer and a belt drive with belt tensioning system for the thermal wheel. E. Controls and Wiring: Factory-installed microprocessor type to control and monitor unit and communicate to central-control processor, How Long Should A Dehumidifier Run Per Day and shall operate dehumidification units and maintain humidity and temperature set points. 

The controller shall be connected to the building DDC control system via an open protocol BAC net interface. 1. The unit shall have a factory wired and unit mounted central, How Long Should A Dehumidifier Run Per Day electrical control panel with a single power supply connection. All internal wiring shall be in accordance with the National Electrical Code. 

Unit shall have a non-fused main power disconnect and control components required for automatic operation based on signals from space mounted duct mounted humidity How Long Should A Dehumidifier Run Per Day and temperature controls. Control panel shall have terminals for remote control devices. 2. Controls shall be capable of shutting down the dehumidifier when humidity loads are reduced and the process shall be reversed when there is an increase in humidity loads. 

3. Reactivation energy shall be automatically reduced at lower than design humidity loads. 4. Carbon dioxide sensor mounted in return air shall operate minimum outdoor-air damper position. Discharge-air, outdoor-air, conditioned-space, How Long Should A Dehumidifier Run Per Day control set-point-temperature, and outdoor-air enthalpy shall be displayed with a LCD in control panel. 

6. Filter pressure drop and alarm shall be displayed by an LCD in control panel. 7. Airflow, fans, system, unit operation, and operating mode status shall be displayed in control panel. SPEC WRITER NOTE Select a housed centrifugal fan How Long Should A Dehumidifier Run Per Day or a plenum fan to suit specific application. F. Fan Section: Housed Centrifugal Fans 

1. Supply and exhaust fans, shall be centrifugal, galvanized steel with baked enamel power coated finish, and shall be belt driven with adjustable sheaves and self-aligning, How Long Should A Dehumidifier Run Per Day grease-lubricated ball bearings with extended grease fittings easily accessible inside the / casing for process and reactivation air as scheduled. 

2. Fans shall be AMCA class II construction, double-width, and double-inlet centrifugal air foil forward cured How Long Should A Dehumidifier Run Per Day or / backward inclined or plug type, factory dynamically balanced and rated in accordance with AMCA standard 210. 3. Fan sized for greater than 3000 CFM shall be belt / driven. Belts shall be sized for 150 percent of fan motor HP. 

4. Fans shall be vibration isolated internally or externally. 5. Connections at fan How Long Should A Dehumidifier Run Per Day discharge shall have flexible duct / connectors. 6. Fan motor and Drive: Motors shall be nominal 1750 RPM. Motor for reactivation fan may be direct-drive 3500 RPM. 

Motors shall / be NEMA MG 1 Design B with open drip-proof housing How Long Should A Dehumidifier Run Per Day and a minimum service factor of 1.15 complying with requirements in specification Section 230511, COMMON WORK RESULTS FOR HVAC. 7. Plenum Fans Single and/ or Multiple Fans in an Array.

Mold Remediation Protocol

If the remediation job disturbs mold and mold spores become airborne, then the risk of respiratory exposure goes up. Actions that are likely to stir up mold include: breakup of moldy porous materials such as wallboard; invasive procedures used to examine or remediate mold growth in a wall cavity; ac  read more..

Flood Damage

Most of the time when there is a tornado or hurricane, there is a certain amount of Emergency Board up Flood Damage, from a long period of rain before, during and after the epicenter of the storm. In order to make preparations for a long duration of steady wind, rain and flying debris, is a good idea to secure your hom  read more..

Foundation Repair Companies

Once a building has been exposed to a large volume of water, either floodwater or rainwater, steps must be taken to dry the building out, assess damage, and plan for repairs and restoration. This Basement Drying Foundation Repair Companies information sheet discusses concerns and procedures for helping structures to dry out. Flooding may  read more..

Remove Smoke Odor From A Kitchen Fire

Electronic air cleaners, such as electrostatic precipitators (ESPs) and ionizers. ESPs use a small electrical charge to collect particles from air pulled through the device. Ionizers, or negative ion generators, Smoke Damage Remove Smoke Odor From A Kitchen Fire cause particles to stick to materials (such as carpet and walls) near the  read more..

Fire damaged odor removal

In order to successfully remove smoke odor from your Odor Control Fire damaged odor removal home there are a few things you could try. Hopefully this article will help these are just a few of the things that professionals try using common things around your home. Inside of your refrigerator you could take baking soda in an   read more..

Mold Abatement Regulations

This article presents remediation guidelines for building materials that have or are likely to have mold growth. The guidelines are designed to protect the health of cleanup personnel and other workers during remediation. These guidelines are based on the size of the area impacted by mold contaminat  read more..

How To Heat A Crawlspace For Frozen Pipes

Flooding of homes and other buildings frequently results in damage to clothing and other items. Depending on the items involved, some may be easily salvaged while others probably are not worth the work or Crawl Space Drying How To Heat A Crawlspace For Frozen Pipes expense to clean and disinfect them. 

Health ri  read more..

Asbestos Abatement

If you are reading this article, it is most likely that an Tenant Move Out Cleanup Asbestos Abatement will be performed nearby to your home or office in the future. While not inclusive, this article will try to answer many of the usual inquiries that most people might have under these conditions. Asbestos-containing building mater  read more..

How To Fix A Flooded Basement

Pumping Out a Flooded Basement If your basement is flooded, don’t rush to pump it out. Water in the ground outside your house is pushing against the outside of your basement walls, and the water inside is pushing right back. If you drain your basement too quickly, the pressure outside the walls wil  read more..

Water Leak Detector

Leaking plumbing fixtures within homes can cause high water bills, excessive loss of water, and increased flow to the sewer system. Toilets Many leaks occur in toilets and may not be immediately recognized since there is no visible sign of a leak. Leaks in toilets can occur at the overflow pipe   read more..