Dehumidification >> How To Choose A Professional Dehumidifier

Flat-plate heat exchangers consist of a series of flat How To Choose A Professional Dehumidifier or nearly flat heat exchange surfaces arranged in such a way that alternating air passages are connected to one air stream with remaining passages connected to the second air stream. the recuperative application of the air-to-air flat-plate heat exchanger. 

The precooling section should be sloped in the direction of air flow to a condensate drain. Advantages. The main advantages of flat-plate heat exchangers are: They have no moving parts. They have no external connection to water circuits, ethylene glycol, refrigerant, How To Choose A Professional Dehumidifier or electricity. They have no heat-transfer fluids that are subject to freezing. 

Disadvantages of flat-plate heat exchangers are: Control is impossible unless bypass How To Choose A Professional Dehumidifier dampers are used. The physical arrangement of their external components is more restrictive than that of the other recuperative-dehumidification enhancements because of the requirement of alternate air streams in cross-flow or counterflow arrangements. 

ARI-certified ratings are not available. Some leakage How To Choose A Professional Dehumidifier or cross flow may occur if the sealant at the edge of plates is not perfect. ROTARY-WHEEL HEAT EXCHANGERS The rotary-wheel heat exchanger usually consists of a honeycomb (fluted) aluminum rotor. An 8-in.- wide corrugated layer of aluminum sheet and an 8-in.-wide flat aluminum sheet are wound around a hub to create an 8-in.-deep rotor (depth varies by manufacturer) with diameters up to about 8 ft. 

The rotor usually is encased in a housing (cassette) that includes seals at the wheel periphery How To Choose A Professional Dehumidifier and at the sectional divider between air streams. The rotor housing is ducted to the two air streams as shown in Figure 7. Onehalf of the rotor picks up heat from the warm air stream. As the rotor rotates at about 20 rpm, this heat is transferred to the cool air stream. 

Advantages.The main advantages of rotary-wheel heat exchangers are: There is no water, How To Choose A Professional Dehumidifier ethylene glycol, or refrigerant charge. Control is easy. They have no heat-transfer fluids that are subject to freezing. Disadvantages. Disadvantages of rotary-wheel heat exchangers are: A restricted physical arrangement of inlet and outlet air streams. 

The requirement of 120-v, 60-cycle single-phase power to a fractional-hp motor. ARI-certified ratings are not available. The media in the rotor may be susceptible to clogging. Some drive systems How To Choose A Professional Dehumidifier have been unreliable or have required high maintenance. The life of the rotor may be shorter than that of other options. 

Leakage between air streams reduces effective air quality and performance. The initial leakage rate may be acceptable; however, How To Choose A Professional Dehumidifier the wearing of seals, etc. can result in increased leakage. Condensation may be detrimental to some types of rotors and media. REFRIGERANT LIQUID SUBCOOLING/AIR REHEATING 

Reheating a cooled air stream using heat from liquid refrigerant en route to a direct-expansion cooling coil is quite desirable from an efficiency standpoint, How To Choose A Professional Dehumidifier as it requires only a single coil to accomplish what the previous arrangements do with two heat-transfer devices. Figure 8 illustrates this dehumidification enhancement. 

The temperature of the refrigerant liquid supplied to a direct-expansion coil often is in the 90- to 115-F range. The reheat coil uses this warm liquid to reheat the cold air stream while simultaneously subcooling the liquid refrigerant. The subcooled liquid refrigerant then enters the direct expansion coil and, because it is subcooled, How To Choose A Professional Dehumidifier increases the latent and total capacity of the cooling coil. 

Figure 9 shows compressor-condenser capacity with and without subcooling as well as evaporator-cooling-coil capacity. The reheat energy is free and the penalties of increased refrigeration How To Choose A Professional Dehumidifier or the expense of additional cooling energy are avoided. The net effect of this cycle is identical to that of the run-around enhancements with two beneficial exceptions.

A precooling coil is not required How To Choose A Professional Dehumidifier and (2) the row depth of the reheat coil is less than that of the heat pipe or run-around coil. A limitation of this method is the small amount of heat available. For example, in an R-22 system with liquid refrigerant entering the reheat coil at 95 F and leaving at 55 F, the total amount of heat available is 2000 Btu per ton-hr. 

Assuming an air-circulation rate of 350 cfm per ton, this results in a 5.2-F rise in air temperature across. the reheat coil. With 100-percent outside-air systems at less than 200 cfm per ton, the temperature rise is approximately 10 F. If the reheat from this coil is not sufficient, How To Choose A Professional Dehumidifier an additional heating coil using some other form of energy is required. 

This adds to the first cost, the space required, and the control complexity. A 5-F rise in air temperature in a 350-cfm-per-ton system may appear small; however, when this system is retrofitted to an existing unit, How To Choose A Professional Dehumidifier the amount of moisture removal increases by approximately 50 percent because of the combined effects of greater moisture removal per minute by the cooling/dehumidifying coil and longer run time attributed to the increase in supply-air temperature by the reheat coil. 

Figure 8 shows the piping of the refrigerant-liquid/reheat coil. The reheat coil is part of the refrigerant liquid line, How To Choose A Professional Dehumidifier with the additional refrigerant charge equal to the volume of the reheat-coil tubes and additional piping. Some manufacturers balk at installing a liquid-subcooling/air-reheating coil in a system (the effect of the coil on the refrigeration system is the same as that of an additional 20 or 30 ft of liquid line in a 60-F room). 

If a winter heating source is located upstream from the refrigerant-liquid-reheat coil, then the refrigerant circuit must be checked to ensure that the refrigerant has a path to the receiver How To Choose A Professional Dehumidifier and is not blocked by isolation valves. If the liquid-refrigerant coil is isolated by line valves during the winter, then high pressures could be a problem. 

Advantages. The advantages of refrigerant-subcooling/air-reheating dehumidification are: There are no water circuits to freeze How To Choose A Professional Dehumidifier or ethylene-glycol charges to maintain. Electrical connections are not required. Controls are not required for most systems. Only a single coil is required in the air stream leaving the main cooling coil. 

Air resistance is approximately half of that of the previous enhancements. Disadvantages. Disadvantages of refrigerant-subcooling/air-reheating dehumidification are: The cost of the additional refrigerant charge and, in retrofit applications, the isolation, evacuation, How To Choose A Professional Dehumidifier and recharging of the refrigerant circuit. 

Possible bursting pressures if relief provisions are not made when the coil is located downstream from the heating apparatus. Concerns about refrigerant migration and inventory management, How To Choose A Professional Dehumidifier particularly in heat-pump refrigeration cycles. Controls, if required, add expense.

Water Restoration

I've been a local Crawl Space Drying Water Restoration for 17 years and in the area of the country that I work there are many mobile homes and many prefab houses that have crawlspaces. I have seen every kind of water damage from a burst pipe, to a leaking condensation line and leaking water heaters. I have seen minor cases   read more..

Radon

The EPA recommends that you should have a qualified radon mitigation contractor Radon Mitigation Radon your home because lowering the high radon gas levels requires a specific technical knowledge and a special set of skills. Without the proper tools and equipment or the technical knowledge, you might actually   read more..

The Effects Meth Labs Have On Wildlife And Vegetat

In addition to the General Cleanup Requirements in Section B, at aminimum a typical cleanup for a Tier 2 Response shall Meth Lab Cleanup The Effects Meth Labs Have On Wildlife And Vegetat include the following:1) Where applicable/appropriate, follow all cleaning procedures described in Tier 1.2) This Tier differs from Tier 1 Responses in that additional af  read more..

Hurricane Ceiling Leak Fix

Note that this requirement is not very satisfactory. At the end of a water absorption experiment, i.e., when the moisture front has reached the sample top, a moisture content profile is still present over the sample. Leaving the sample in water contact for a longer period of time slightly increases   read more..

The Best Ways To Dry Out A Flooded Basement

If your house has been substantially damaged or is being substantially improved, your community’s floodplain management ordinance or law will not allow you to have a basement, as defined under the National Flood Insurance Program (NFIP). The NFIP regulations define a Basement Drying The Best Ways To Dry Out A Flooded Basement asement as   read more..

How To Stop Animals From Digging Up Flower Beds

Direct control assistance is implemented when the problem cannot effectively be resolved through technical assistance, and when Cooperative Agreements provide for direct control assistance. The initial investigation defines the nature and history of the problem, extent of damage, and the species res  read more..

Hoarding Tips To Get Organized

Imagine going into a smoke-filled home with boxes and papers stacked from floor to ceiling. You can't see anything and getting through the house is almost impossible. That is the type of situation the Tempe Fire Department encounters all too often. Hoarding makes it difficult for first responders to  read more..

Tsunami Facts

Tsunami (pronounced soo-n¡-mees), also known as seismic sea waves (mistakenly called "tidal waves”), are a series of enormous waves created by an underwater disturbance such as an earthquake, landslide, volcanic eruption, or meteorite. A Flood Damage Tsunami Facts can move hundreds of miles per hour in the open ocean   read more..

How To Clean Sewer Overflows In Your House

Do you have a chronic sanitary sewer backup problem? The City of Decatur has a program to help stop sewer backups in your home. The Sewage Cleanup How To Clean Sewer Overflows In Your House program is available to homeowners within the City of Decatur city limits. This brochure gives overview of the "Sanitary Sewer Backup Prevention Program"  read more..

Lead Paint Removal Methods In California

It should be kept in mind that this is not a rigorous comparison; it is not based on a staged side-by-side use of the different methods to remove the same mass of paint containing the same percentage weight of lead. This lack of strict methodological control somewhat weakens the case for substitutio  read more..