Dehumidification >> How To Choose A Professional Dehumidifier

Flat-plate heat exchangers consist of a series of flat How To Choose A Professional Dehumidifier or nearly flat heat exchange surfaces arranged in such a way that alternating air passages are connected to one air stream with remaining passages connected to the second air stream. the recuperative application of the air-to-air flat-plate heat exchanger. 

The precooling section should be sloped in the direction of air flow to a condensate drain. Advantages. The main advantages of flat-plate heat exchangers are: They have no moving parts. They have no external connection to water circuits, ethylene glycol, refrigerant, How To Choose A Professional Dehumidifier or electricity. They have no heat-transfer fluids that are subject to freezing. 

Disadvantages of flat-plate heat exchangers are: Control is impossible unless bypass How To Choose A Professional Dehumidifier dampers are used. The physical arrangement of their external components is more restrictive than that of the other recuperative-dehumidification enhancements because of the requirement of alternate air streams in cross-flow or counterflow arrangements. 

ARI-certified ratings are not available. Some leakage How To Choose A Professional Dehumidifier or cross flow may occur if the sealant at the edge of plates is not perfect. ROTARY-WHEEL HEAT EXCHANGERS The rotary-wheel heat exchanger usually consists of a honeycomb (fluted) aluminum rotor. An 8-in.- wide corrugated layer of aluminum sheet and an 8-in.-wide flat aluminum sheet are wound around a hub to create an 8-in.-deep rotor (depth varies by manufacturer) with diameters up to about 8 ft. 

The rotor usually is encased in a housing (cassette) that includes seals at the wheel periphery How To Choose A Professional Dehumidifier and at the sectional divider between air streams. The rotor housing is ducted to the two air streams as shown in Figure 7. Onehalf of the rotor picks up heat from the warm air stream. As the rotor rotates at about 20 rpm, this heat is transferred to the cool air stream. 

Advantages.The main advantages of rotary-wheel heat exchangers are: There is no water, How To Choose A Professional Dehumidifier ethylene glycol, or refrigerant charge. Control is easy. They have no heat-transfer fluids that are subject to freezing. Disadvantages. Disadvantages of rotary-wheel heat exchangers are: A restricted physical arrangement of inlet and outlet air streams. 

The requirement of 120-v, 60-cycle single-phase power to a fractional-hp motor. ARI-certified ratings are not available. The media in the rotor may be susceptible to clogging. Some drive systems How To Choose A Professional Dehumidifier have been unreliable or have required high maintenance. The life of the rotor may be shorter than that of other options. 

Leakage between air streams reduces effective air quality and performance. The initial leakage rate may be acceptable; however, How To Choose A Professional Dehumidifier the wearing of seals, etc. can result in increased leakage. Condensation may be detrimental to some types of rotors and media. REFRIGERANT LIQUID SUBCOOLING/AIR REHEATING 

Reheating a cooled air stream using heat from liquid refrigerant en route to a direct-expansion cooling coil is quite desirable from an efficiency standpoint, How To Choose A Professional Dehumidifier as it requires only a single coil to accomplish what the previous arrangements do with two heat-transfer devices. Figure 8 illustrates this dehumidification enhancement. 

The temperature of the refrigerant liquid supplied to a direct-expansion coil often is in the 90- to 115-F range. The reheat coil uses this warm liquid to reheat the cold air stream while simultaneously subcooling the liquid refrigerant. The subcooled liquid refrigerant then enters the direct expansion coil and, because it is subcooled, How To Choose A Professional Dehumidifier increases the latent and total capacity of the cooling coil. 

Figure 9 shows compressor-condenser capacity with and without subcooling as well as evaporator-cooling-coil capacity. The reheat energy is free and the penalties of increased refrigeration How To Choose A Professional Dehumidifier or the expense of additional cooling energy are avoided. The net effect of this cycle is identical to that of the run-around enhancements with two beneficial exceptions.

A precooling coil is not required How To Choose A Professional Dehumidifier and (2) the row depth of the reheat coil is less than that of the heat pipe or run-around coil. A limitation of this method is the small amount of heat available. For example, in an R-22 system with liquid refrigerant entering the reheat coil at 95 F and leaving at 55 F, the total amount of heat available is 2000 Btu per ton-hr. 

Assuming an air-circulation rate of 350 cfm per ton, this results in a 5.2-F rise in air temperature across. the reheat coil. With 100-percent outside-air systems at less than 200 cfm per ton, the temperature rise is approximately 10 F. If the reheat from this coil is not sufficient, How To Choose A Professional Dehumidifier an additional heating coil using some other form of energy is required. 

This adds to the first cost, the space required, and the control complexity. A 5-F rise in air temperature in a 350-cfm-per-ton system may appear small; however, when this system is retrofitted to an existing unit, How To Choose A Professional Dehumidifier the amount of moisture removal increases by approximately 50 percent because of the combined effects of greater moisture removal per minute by the cooling/dehumidifying coil and longer run time attributed to the increase in supply-air temperature by the reheat coil. 

Figure 8 shows the piping of the refrigerant-liquid/reheat coil. The reheat coil is part of the refrigerant liquid line, How To Choose A Professional Dehumidifier with the additional refrigerant charge equal to the volume of the reheat-coil tubes and additional piping. Some manufacturers balk at installing a liquid-subcooling/air-reheating coil in a system (the effect of the coil on the refrigeration system is the same as that of an additional 20 or 30 ft of liquid line in a 60-F room). 

If a winter heating source is located upstream from the refrigerant-liquid-reheat coil, then the refrigerant circuit must be checked to ensure that the refrigerant has a path to the receiver How To Choose A Professional Dehumidifier and is not blocked by isolation valves. If the liquid-refrigerant coil is isolated by line valves during the winter, then high pressures could be a problem. 

Advantages. The advantages of refrigerant-subcooling/air-reheating dehumidification are: There are no water circuits to freeze How To Choose A Professional Dehumidifier or ethylene-glycol charges to maintain. Electrical connections are not required. Controls are not required for most systems. Only a single coil is required in the air stream leaving the main cooling coil. 

Air resistance is approximately half of that of the previous enhancements. Disadvantages. Disadvantages of refrigerant-subcooling/air-reheating dehumidification are: The cost of the additional refrigerant charge and, in retrofit applications, the isolation, evacuation, How To Choose A Professional Dehumidifier and recharging of the refrigerant circuit. 

Possible bursting pressures if relief provisions are not made when the coil is located downstream from the heating apparatus. Concerns about refrigerant migration and inventory management, How To Choose A Professional Dehumidifier particularly in heat-pump refrigeration cycles. Controls, if required, add expense.

What Are The Dangers Of Sewage Backups

Use of root remover products - A number of root remover products are available commercially. Be sure to follow all of the manufacturer's instructions. Although these products may not completely eliminate the growth, they may increase the interval between Sewage Cleanup What Are The Dangers Of Sewage Backups needed rodding. 3. Sewer pipe   read more..

Toxic Waste Cleanup

A Crime Scene Cleanup Toxic Waste Cleanup professional supplies a very valuable service to people and their families who endured some kind of a violent crime scene or suicide within their own home. One of these crime scene clean up professionals will usually get things back in order, removing the remnants of the grue  read more..

When Does The Law Require Removal Of Friable Asbes

Compliance program. Where the and/or excursion limit is exceeded, the employer shall establish and implement a written program to reduce employee exposure to or below the and to or below the excursion limit by means of engineering and work practice controls as required by paragraph (f)(1) of this [M  read more..

How To Get Rid Of Standing Water In A Crawl Space

Chemical preservative treatment against decay is especially likely to repay its cost for porches, outside steps, and railings made of wood of low natural durability. Crawl Space Drying How To Get Rid Of Standing Water In A Crawl Space There are commercial impregnation treatments available for wood to be painted. 

When a  read more..

Natural Repellents

Some people like to spend a lot of time and maybe a lot of money on their garden. But it can be frustrating when raccoons, rabbits, deer and other animal damage is destroying your garden. Animal control repellents might work, but they also might damage your plants. There are a number of natur  read more..

Bee Removal

Removing a nest of bees can be a challenging and dangerous undertaking, the utmost caution is advised. If you do not possess the right kind of equipment or the know-how this job might be well served to be left to the professionals. Depending on which part of the country that you live in, beca  read more..

Remove Paint If You Dont Know If It Contains Lead

The standard also provides for a program of biological monitoring and medical surveillance for all employees exposed to levels of inorganic lead above the action level of 30 µg/m3 (TWA) for more than 30 days per year. The purpose of this document is to outline the medical surveillance provisions   read more..

Natural Disaster Safety Tips

You may be surprised by what you find when you get back home after a flood. Water may still be standing in your yard or your house. Many of your belongings may be damaged Water Damage Natural Disaster Safety Tips or destroyed. There will be changes in your house, your yard and your neighborhood. Some of those changes may hurt  read more..

Illinois Regulations For Asbestos Removal

What is Vermiculite? Vermiculite is a naturally-occurring mineral composed of shiny flakes, resembling mica. When heated to a high temperature, flakes of vermiculite expand as much as 8-30 times their original size. The expanded vermiculite is a light-weight, fire-resistant, and odorlessà read more..

How To Remove Chipped Lead Paint

Before Entering the Work Area Select the proper PPE for the hazards that are likely to be present. Put on protective clothing in a clean area. Make sure PPE fits properly and is in good working condition. Store street clothes in a clean area.When Leaving the Work Area Remove loose dust from clothing  read more..