Dehumidification >> How To Dehumidify Air

Dehumidification Options Tunnel Moisture Load: The cost of dehumidification is directly related to How To Dehumidify Air the moisture the tunnel air will pick up from water sources in the tunnel. To keep the air dry at low cost, it will be essential that water sources are eliminated or kept to a minimum. Areas where tunnel walls show excessive infiltration should be sealed if possible. 

Water should not be allowed to pool or run through open trenches - drainage should be provided in a closed piping system. The 35km tunnel is approx. 6 times the How To Dehumidify Air size of the current Main Ring tunnel. A recent study of dehumidification issues in the Main Ring showed that humidity comes from 3 principle sources besides the ventilation air intake.

These are: 1. Transmission through concrete = 5 lb/hr 2. Trench and sump evaporation = 170 lb/hr 3. Allowance for water spray from leaks = 70 lb/hr which gives a figure for How To Dehumidify Air moisture build-up in the Main Ring of 245 lb/hr. If we multiply this by the factor of 6 increase in tunnel length for the 3 TeV machine we would have over 1000 lb/hr in moisture released to the tunnel air. 

This straight forward scaling does not directly apply, because water spray from leaks should not be an issue as only cryogens are anticipated in the tunnel. However, trench and sump evaporation, if multiplied by a factor of 6, How To Dehumidify Air would result in 1000 lbs/hr release to the air.Because the dolomite is not a good water conductor at a depth of 400 feet, we can be optimistic about controlling water penetration through the tunnel rock, especially if care is taken to seal the bad spots. 

Trench and sump evaporation can be improved by use of enclosed drain lines and sealed sumps. With How To Dehumidify Air these considerations in mind, we would design a basic dehumidification system to handle 200 lbs/hr, with provision for expansion if conditions prove more extreme in reality. Ventilation System Capacity: The ventilation system shown in figure 1 allows for the minimum breathing requirements for tunnel personnel. 

Air is introduced into the tunnel at one of the two access shafts, and released at the other, How To Dehumidify Air the two halves of the ring being fed in parallel.The system shown has a capacity of about 15,000cfm which results in a 100fpm wind (1mph) through the tunnel and a 1”wc differential pressure end to end. This minimal ventilation reduces moisture load from outside air intake to a minimum, however, it also results in a 10 hour air purge time for the tunnel. 

The cost for this scale of system (not including tunnel ducting) would be about $700K1 . It would have the ability to remove 200 lb/hr of tunnel moisture (in addition to outside air moisture) to How To Dehumidify Air keep the tunnel moisture below the dew point at 55F. The ventilation unit will have to be fitted with heating capacity for winter operation. The ventilation system could be increased to allow for additional capacity.For every 1 lb/hr of tunnel moisture, 75cfm of additional air flow would be needed, at a unit cost of about $3.5K (not including tunnel ductwork).

 At a size of 150,000cfm (allowing the tunnel to be purged in 1 hour) the ventilation system would be able to remove 1800 lb/hr of moisture and with economies of How To Dehumidify Air scale would cost about $5M (not including tunnel ductwork). Air velocities in the tunnel would be about 1000fpm (10 mph) and require a differential pressure of 8”wc across the tunnel, which would require special design considerations. 

Auxiliary Dehumidifiers: Auxiliary tunnel dehumidification units could be placed down the tunnel length. At a half mile spacing between units, 44 units would be required.To preclude dead spots in the tunnel air movement, How To Dehumidify Air due to these units simply recirculating on themselves, it would probably be necessary to run the ventilation system concurrently. These units normally range from 10 lb/hr (size 300 unit) to 32 lb/hr (size 1200 unit) moisture removal capacity each. This would total 440 to 1408 lb/hr capacity for 44 units. The unit cost of this type of equipment runs about $2.5K per lb/hr capacity (not including electrical installation and assuming that no ducting is necessary). 

An example of a ventilation unit mounted in a 10 foot tunnel is shown in figure 2. Other Considerations The 3 TeV accelerator adds about 3 watts per meter in heating to the tunnel. This How To Dehumidify Air represents about a 100 kwatt heating load. This would increase the tunnel air temperature by about 20 degrees F at the exhaust point. This actually serves to help the dehumidification system in the following sense:

 In the Winter, the chiller system is turned off and the outside air is heated before injection into the tunnel. The extra heating from the accelerator components helps this How To Dehumidify Air process. An Electron Ring An electron ring will loose energy in the tunnel due to synchrotron radiation at a rate that may be as high as 50 Mwatts. Such a high heating load could not be air cooled, and would have to revert to another cooling medium - presumably water. 

The addition of a large water cooling capability into the tunnel could complicate the dehumidification problem, How To Dehumidify Air because of the potential for leaks. Recall that the Main Ring must allow for as much as a 70 lb/hr load that could come from leaky water systems.

 Conclusions A ventilation system for a 3 TeV ring need not be an excessive cost to the project. A great deal depends on the care taken to seal potential water sources in the tunnel. Based on the experience gained at the Main Ring tunnel, How To Dehumidify Air a system that can handle a 200 lb/hr load could very well be sufficient. However, the 200 lb/hr system should be treated somewhat optimistically as a target. As more data become available, and plans for the electron machine firm up, the dehumidification requirements can be predicted with greater certainty.

How To Remove Soot Stains From Stucco

In a final report in the series of non-thermal damage experiments, SNL reports on previously unpublished results including tests of conformal coatings, digital throughput, memory chips, hard disk drives, and electrical properties of fire smoke [19].2.1.7.1 Conformal Coatings In order to gauge the ab  read more..

Safely Get Water Out Of A Flooded Basement

Reinforce walls and footings to minimize shrinkage cracking and cracking due to uneven settlement. To retard movement of radon through hollow core masonry walls, the top and bottom courses of hollow masonry walls should be solid block, Basement Drying Safely Get Water Out Of A Flooded Basement or filled solid. 

  read more..

Smoke Smell From Books After A Fire

Bird and animal mounts on display in the RSM upper-level Life Sciences Gallery were covered with a heavy soot layer. Extensive cleaning tests were done in the conservation laboratory, and results were evaluated by visual examination through a binocular operating microscope. Under microscopic examina  read more..

Flood Damage

After a flood has come through your area flooding your house, be patient and allow your Dehumidification Flood Damage walls ceilings and floors to thoroughly dry for at least a couple of weeks. If you try to repaint or hang wallpaper before proper drying is completed the mildew and mold will continue to grow. The mem  read more..

How To Restore Flood Damaged Archive Photos

To create a collection, to inherit one, or to be given oversight of a collection, is also to create, inherit or accept a great responsibility. The challenge for collecting institutions is to meet the charge of stewardship and to assure that their valued collections, whether works of art, historical   read more..

How To Clean Up A Water Leak In Your Basement Fast

Only two of these four ways to insulate a basement realistically apply: from the interior or from the middle of the wall. It is possible to insulate an existing wall from both the interior and the exterior, but practicality would suggest that such an approach would also be rare because insulati  read more..

Earthquakes

Recent earthquakes around the world show a pattern of steadily increasing damages and losses that are due primarily to two factors: (1) significant growth in earthquake-prone urban areas and (2) vulnerability of the older building stock, Flood Damage Earthquakes including buildings constructed within the past 20 yea  read more..

Wind Damage To Plants

DERECHO FACTS PAGE... Note: Some of the following information, in abbreviated, question-and-answer format, is available in The Derecho FAQ. INTRODUCTION Definition of a derecho A derecho (pronounced similar to "deh-REY-cho" in English, or pronounced phonetically as " ") is a widespread, Wind Damage Wind Damage To Plants&nb  read more..

OCD

Treatments OCD is generally treated with psychotherapy, medication, or both. Psychotherapy. A type of psychotherapy called cognitive behavior therapy is especially useful for treating OCD. It teaches a person different ways of thinking, behaving, and reacting to situations that help him or her feel   read more..

Storm And High Flood Damage Prevention Plan

Mold, mildew and bacteria are common following floods and other water damage. If unchecked they can lead to sanitation and health problems. The walls, floors, closets, shelves, contents-every flooded part of your house-should be thoroughly washed and disinfected.In most cases, Flood Damage Storm And High Flood Damage Prevention Plan household cleanin  read more..