Dehumidification >> How To Dehumidify Air

Dehumidification Options Tunnel Moisture Load: The cost of dehumidification is directly related to How To Dehumidify Air the moisture the tunnel air will pick up from water sources in the tunnel. To keep the air dry at low cost, it will be essential that water sources are eliminated or kept to a minimum. Areas where tunnel walls show excessive infiltration should be sealed if possible. 

Water should not be allowed to pool or run through open trenches - drainage should be provided in a closed piping system. The 35km tunnel is approx. 6 times the How To Dehumidify Air size of the current Main Ring tunnel. A recent study of dehumidification issues in the Main Ring showed that humidity comes from 3 principle sources besides the ventilation air intake.

These are: 1. Transmission through concrete = 5 lb/hr 2. Trench and sump evaporation = 170 lb/hr 3. Allowance for water spray from leaks = 70 lb/hr which gives a figure for How To Dehumidify Air moisture build-up in the Main Ring of 245 lb/hr. If we multiply this by the factor of 6 increase in tunnel length for the 3 TeV machine we would have over 1000 lb/hr in moisture released to the tunnel air. 

This straight forward scaling does not directly apply, because water spray from leaks should not be an issue as only cryogens are anticipated in the tunnel. However, trench and sump evaporation, if multiplied by a factor of 6, How To Dehumidify Air would result in 1000 lbs/hr release to the air.Because the dolomite is not a good water conductor at a depth of 400 feet, we can be optimistic about controlling water penetration through the tunnel rock, especially if care is taken to seal the bad spots. 

Trench and sump evaporation can be improved by use of enclosed drain lines and sealed sumps. With How To Dehumidify Air these considerations in mind, we would design a basic dehumidification system to handle 200 lbs/hr, with provision for expansion if conditions prove more extreme in reality. Ventilation System Capacity: The ventilation system shown in figure 1 allows for the minimum breathing requirements for tunnel personnel. 

Air is introduced into the tunnel at one of the two access shafts, and released at the other, How To Dehumidify Air the two halves of the ring being fed in parallel.The system shown has a capacity of about 15,000cfm which results in a 100fpm wind (1mph) through the tunnel and a 1”wc differential pressure end to end. This minimal ventilation reduces moisture load from outside air intake to a minimum, however, it also results in a 10 hour air purge time for the tunnel. 

The cost for this scale of system (not including tunnel ducting) would be about $700K1 . It would have the ability to remove 200 lb/hr of tunnel moisture (in addition to outside air moisture) to How To Dehumidify Air keep the tunnel moisture below the dew point at 55F. The ventilation unit will have to be fitted with heating capacity for winter operation. The ventilation system could be increased to allow for additional capacity.For every 1 lb/hr of tunnel moisture, 75cfm of additional air flow would be needed, at a unit cost of about $3.5K (not including tunnel ductwork).

 At a size of 150,000cfm (allowing the tunnel to be purged in 1 hour) the ventilation system would be able to remove 1800 lb/hr of moisture and with economies of How To Dehumidify Air scale would cost about $5M (not including tunnel ductwork). Air velocities in the tunnel would be about 1000fpm (10 mph) and require a differential pressure of 8”wc across the tunnel, which would require special design considerations. 

Auxiliary Dehumidifiers: Auxiliary tunnel dehumidification units could be placed down the tunnel length. At a half mile spacing between units, 44 units would be required.To preclude dead spots in the tunnel air movement, How To Dehumidify Air due to these units simply recirculating on themselves, it would probably be necessary to run the ventilation system concurrently. These units normally range from 10 lb/hr (size 300 unit) to 32 lb/hr (size 1200 unit) moisture removal capacity each. This would total 440 to 1408 lb/hr capacity for 44 units. The unit cost of this type of equipment runs about $2.5K per lb/hr capacity (not including electrical installation and assuming that no ducting is necessary). 

An example of a ventilation unit mounted in a 10 foot tunnel is shown in figure 2. Other Considerations The 3 TeV accelerator adds about 3 watts per meter in heating to the tunnel. This How To Dehumidify Air represents about a 100 kwatt heating load. This would increase the tunnel air temperature by about 20 degrees F at the exhaust point. This actually serves to help the dehumidification system in the following sense:

 In the Winter, the chiller system is turned off and the outside air is heated before injection into the tunnel. The extra heating from the accelerator components helps this How To Dehumidify Air process. An Electron Ring An electron ring will loose energy in the tunnel due to synchrotron radiation at a rate that may be as high as 50 Mwatts. Such a high heating load could not be air cooled, and would have to revert to another cooling medium - presumably water. 

The addition of a large water cooling capability into the tunnel could complicate the dehumidification problem, How To Dehumidify Air because of the potential for leaks. Recall that the Main Ring must allow for as much as a 70 lb/hr load that could come from leaky water systems.

 Conclusions A ventilation system for a 3 TeV ring need not be an excessive cost to the project. A great deal depends on the care taken to seal potential water sources in the tunnel. Based on the experience gained at the Main Ring tunnel, How To Dehumidify Air a system that can handle a 200 lb/hr load could very well be sufficient. However, the 200 lb/hr system should be treated somewhat optimistically as a target. As more data become available, and plans for the electron machine firm up, the dehumidification requirements can be predicted with greater certainty.

Water Damage Carpet Cleaning Techniques

External and internal surveys were done to help assess Ohio's science needs. External surveys consisted of a written questionnaire sent to agency personnel who partner Water Extraction Water Damage Carpet Cleaning Techniques or otherwise collaborate (or have the potential to collaborate) with the USGS Ohio Water Science Center; in some case  read more..

How To Remove Flood Damage Debris

General Conditions and Special Provisions Project Schedule: Prepare a time schedule beginning with start of mobilization through completion of demobilization. Provide a timeline for all major items of work. Site Specific Injury and Illness Prevention Plan (IIPP): Prepare a site specific IIPP which  read more..

Remove Radon Gas From A Home

Biennial Measurement Exam The Measurement Exam was updated in July 1994 to include the latest in technological and procedural advancements. The biennial measurement exam will continue to be offered concurrently with the continuing education courses until August 15, 1997, and participants whose renew  read more..

Lead Paint Exposure Registry In California

Legislation in 1986 created a statewide system for tracking lead poisoning cases in children and adults in California (California Health and Safety Code Section 124130). Laboratories are required to report electronically all blood lead levels (BLLs) for persons tested Lead Paint Removal Lead Paint Exposure Registry In California in California to  read more..

How To Pass A Radon Test

Successful IAQ management in schools comprises effective pollution source control. Radon — a radioactive gas — is one of the most hazardous indoor pollutants. Radon is the leading cause of lung cancer among non-smokers. In the U.S., Radon Mitigation How To Pass A Radon Test an estimated 20,000 people die from radon-induced   read more..

How To Clean After Tenants

When the tenant moves out of a rental unit, the landlord has thirty (30) days in which to either return the entire security deposit plus interest if appropriate, or send a written statement of any deductions made from the deposit for repairs, cleaning, etc., the cost of each repair (supported by cop  read more..

Flood Damage

Did you know the average residential house loses 14% of the water delivered to leaks? In an average home, 22 gallons of water are lost to leakage every day, and the usual suspects are leaking toilets or dripping faucets. This daily water leakage amount is ab  read more..

How To Get Rid Of Water In My Basement

Flood Depth
The primary consideration in dry floodproofing, and the one that imposes the greatest limitations on the application of this method, is the effect of hydrostatic pressure. Because dry floodproofing prevents water from entering the house, Basement Drying How To Get Rid Of Water In My Basement the external hydrostatic   read more..

Mold Inspection

Health Concerns If building occupants are reporting serious health concerns, you should consult a health professional. In cases in which a particularly toxic mold species has been identified or is suspected, when extensive hidden mold is expected (such as behind vinyl wallpaper or in the HVAC s  read more..

Removing Smoke Odors From Fire damaged Furniture

The nonprofit NFPA's (National Fire Protection Association) Fire Safety Educational Memorial Fund Committee last month named the Seattle Hazmat Response Team, Seattle, Fire Damage Removing Smoke Odors From Fire damaged Furniture Washington as the 2004 recipient of the Warren E. Isman Educational Grant.

The team will use the grant to atten  read more..