Dehumidification >> Will A Dehumidifier Stop A Musty Smell

Technical data on design operating inlet and outlet conditions, air flows with diagram showing air volumes and conditions throughout the system, dehumidification capacity, filtration and fan motor and electrical power data. A general arrangement diagram with overall Will A Dehumidifier Stop A Musty Smell dimensions showing all major components with overall dimensions, utility and duct work connections, bolting arrangement, operating weight and required service and equipment removal clearances.
 
 Control diagrams for preconditioning of existing and or new air conditioning system stand alone use for dehumidifying air, electric circuits interface all control set points. Shop drawings shall indicate assembly, unit dimensions, weight loading, required clearances, Will A Dehumidifier Stop A Musty Smell construction details, and field connection details. Submit fan curves with specified operating point clearly plotted and sound power levels for both fan outlet and casing radiation at rated capacity.
 
Submit unit control system documentation required for interface with BACnet protocol DDC control system. Submit BACnet Will A Dehumidifier Stop A Musty Smell compliant Protocol Implementation Conformance Statement (PICS) for all controllers. Submit electrical requirements for power supply wiring including wiring diagrams for interlock and control wiring, clearly indicating factory‑installed and field‑installed wiring.
 
Certificate: Evidence of satisfactory performance on three similar installations. Provide installation, operating and maintenance instructions, in accordance with Article, INSTRUCTIONS, in specification Section 010000, GENERAL REQUIREMENTS. Performance test report: In accordance with PART 3. Completed System Readiness Will A Dehumidifier Stop A Musty Smell Checklists provided by the Commissioning Agent and completed by the contractor, signed by a qualified technician and dated on the date of completion, in accordance with the requirements of Section 23 08 00 COMMISSIONING OF HVAC SYSTEMS.
 
 applicable publications. The publications listed Will A Dehumidifier Stop A Musty Smell below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. Air-conditioning, Heating and Refrigeration Institute (AHRI) Forced–Circulation Air-Cooling and Air-Heating Coils C. Air Movement and Control Association (AMCA): Standards Handbook Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (ANSI) Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (ANSI) American Society of Heating, Refrigerating and Air-Conditioning Engineers.
 
 METHOD OF TESTING General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size (ANSI). Ventilation for Acceptable Indoor Air Quality (ANSI) E. American Bearing Manufacturers Association (ABMA) 9-1990 Load Ratings and Will A Dehumidifier Stop A Musty Smell Fatigue Life for Ball Bearings (ANSI) F. National Fire Protection Association (NFPA) Standard for the Installation of Air-Conditioning and Ventilating Systems decoration: line-through; National Electrical Code 1.6 QUALITY ASSURANCE Fan Performance Ratings: Conform to AMCA 210 and bear the AMCA Certified Rating Seal.
 
 B. Sound Ratings: AMCA 301; tested to AMCA 300 and bear AMCA Certified Sound Rating Seal. C. Fabrication: Conform to AMCA 99. D. Air Coils: Certify capacities, pressure drops, and selection Will A Dehumidifier Stop A Musty Smell procedures in accordance with. Product of manufacturer regularly engaged in production of pool dehumidification equipment who issues complete catalog data on total product. Accept products on site in factory-fabricated protective containers, with factory-installed shipping skids and lifting lugs. Inspect for damage.
 
B. Store in clean dry place and protect from weather and construction traffic. Handle carefully to avoid damage to components, enclosures Will A Dehumidifier Stop A Musty Smell and finish. C. Comply with manufacturer rigging and installation instructions.
 
 PROJECT CONDITIONS
Do not operate units for any purpose, temporary or permanent, Will A Dehumidifier Stop A Musty Smell until duct work is clean, filters are in place, bearings lubricated, fan has been test run, all piping is connected and energized and all wiring complete and tested.
 
1.9 ADDITIONAL REQUIREMENTS
A. Provide one additional set of fan belts and disposable Will A Dehumidifier Stop A Musty Smell panel filters for each unit. Provide corrosion protection for all coils (located in the air-handling unit) and the casing surfaces, exterior and interior, exposed to ambient air in high-humidity locations (VA HVAC Design Manual Chapter 7) and as determined by the designer for a specific location. Coating should not be used or the chemically corrosive locations where the pH values are not within 3 to 12.
 
CORROSION PROTECTION
For air-handling unit mounted coils provide the following corrosion treatment: 1. Epoxy Immersion Coating – Electrically Will A Dehumidifier Stop A Musty Smell Deposited: The multi-stage corrosion-resistant coating application comprises of cleaning (heated alkaline immersion bath) and reverse-osmosis immersion rinse prior to the start of the coating process. The coating thickness shall be maintained between 0.6-mil and 1.2-mil.
 
Before the coils are subjected to high-temperature oven cure, they are treated to permeate immersion rinse and Will A Dehumidifier Stop A Musty Smell spray. Where the coils are subject to UV exposure, UV protection spray treatment comprising of UV-resistant urethane mastic topcoat shall be applied. Provide complete coating process trace ability for each coil and minimum five years of limited warranty. 2. The coating process shall such that uniform coating thickness is maintained at the fin edges.
 
The quality control shall be maintained by ensuring compliance to the applicable ASTM Standards for the Will A Dehumidifier Stop A Musty Smell following: a. Salt Spray Resistance (Minimum 6,000 Hours) b. Humidity Resistance (Minimum 1,000 Hours) c. Water Immersion (Minimum 260 Hours) d. Cross-Hatch Adhesion (Minimum 4B-5B Rating) e. Impact Resistance (Up to 160 Inch/Pound)Will A Dehumidifier Stop A Musty Smell Casing Surfaces (Exterior and Interior): All exposed and accessible exterior and interior metal surfaces shall be protected with a water-reducible acrylic with stainless steel pigment spray-applied over the manufacturer’s standard finish.
 
The spray coating thickness shall be 2-4 mils and provide minimum salt-spray resistance of 1,000 hours (ASTM B117) and 500 hours UV resistance (ASTM D4587). part 2– products 2.1 dehumidifier units A. General: Units shall be complete, factory assembled, and tested; and of sizes, arrangements, capacities, and performance Will A Dehumidifier Stop A Musty Smell as scheduled and as specified in the schedules shown in the drawings; and for indoor outdoor installation preconditioning of existing and new air conditioning system stand alone use for dehumidifying air.
 
SPEC WRITER NOTES:
1. Add chilled water section for situations when applications where post cooling is required. 2. The components included in the following paragraphs represent the wide range of components available to apply dehumidification systems to buildings. Will A Dehumidifier Stop A Musty Smell The designer must edit the following to include the components applicable to the project design requirements. Dehumidification shall be accomplished by use of a desiccant to absorb water vapor and maintain humidity control level independent of load variations within design limit and without use of refrigerants, compressors, or chilled water.

Leaking Shower Caused Wet Carpet

Molds are types of fungi that are found everywhere. Molds reproduce by means of tiny spores; the spores are invisible to the naked eye and float through outdoor and indoor air. Mold may begin growing indoors when mold spores land on Water Damage Leaking Shower Caused Wet Carpet surfaces that are wet. 

  read more..

How To Survive A Hurricane

Foundations are at relatively low risk from wind forces, but are at higher risks from water forces in wave erosion zones and flood zones. In flooding and wave erosion zones, Wind Damage How To Survive A Hurricane homes are typically elevated above base flood elevation (BFE), defined as the elevation having a 1% chance of b  read more..

Crime Scene Cleanup

Methamphetamine laboratories or simply meth labs and there are dump sites for their by-products. Meth Lab Cleanup Crime Scene Cleanup production can be found anywhere in the United States and everywhere in rural, urban, and suburban areas, like outdoors or in houses, apartments, trailers homes, storage sheds, barns, hotels,   read more..

How To Clean Up Water In A Flooded Basement

Cleaning a basement after a flood Basements flooded with surface water, seepage through walls, or backflow from Basement Drying How To Clean Up Water In A Flooded Basement sewer lines often suffer little or no structural damage from the water, because the water inside braces the walls against the pressure of outside water and waterlogged soil. How   read more..

Information About Mold

What are molds? Molds are microscopic organisms that live on plant or animal matter. They aid in the break down of dead material and recycle nutrients in the environment. Present virtually everywhere, they can be found growing on organic material such as soil, foods, and plant matter. In order to re  read more..

Grants For Tornado Damage Tree Removal

Building demolition debris Approximately 300 houses in Lincoln County sustained damage amounting to more than 50 percent of the value of the house. Most of these homeowners chose to sell their properties to the county in a buyout and demolition program. FEMA and the state Community Development Block  read more..

Respirator Selection For Lead Dust Removal

Respirator Selection. (A) The employer shall select the appropriate respirator or combination of respirators from the following table. (B) The employer shall provide a powered, air purifying respirator in lieu of the respirator specified in Section 5198(f)(3)(A) whenever: 1. An Lead Paint Removal Respirator Selection For Lead Dust Removal employ  read more..

How To Damp Proof An Interior Basement Floor

Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a   read more..

FEMA Map

If my community is not participating in the CRS, what can I do to have my community join? The decision to join the CRS is a voluntary action of a community's elected officials. As with many community actions, citizens can contact their local elected officials and encourage the community to consider   read more..

The Tenant Who Leaves Trash Behind

If circumstances change Once the tenant and the landlord make a rental agreement, the tenant may NOT have the right to get back full deposits or prepaid rent if he or she decides not to move in.In a month-to-month tenancy, the tenant is responsible for as much as one month's rent, or Tenant Move Out Cleanup The Tenant Who Leaves Trash Behind   read more..