The following recount criterion is for a pair of counts that estimate AC in fibers/cc. The criterion is given at the type-I error level. That is, there is 5% maximum risk that we will reject a pair of counts for the reason that one might be biased, when the large How To Remove Asbestos Siding observed difference is really due to chance. 

Reject a pair of counts if: Where: AC1 = lower estimated  airborne fiber concentration AC2 = higher estimated airborne fiber concentration ACavg = average of the two concentration estimates (FB) = for the average of the two   concentration estimates If a pair of counts are rejected by this criterion then, recount the rest of the filters in the How To Remove Asbestos Siding submitted set. 

Apply the test and reject any other pairs  failing the test. Rejection shall include a memo to the industrial hygienist stating that the sample failed a statistical How To Remove Asbestos Siding test for homogeneity and the true air concentration may be significantly different than the reported value. 7.4. Reporting Results Report results to the industrial hygienist as fibers/cc. 

Use two significant figures. If multiple analyses are performed on a How To Remove Asbestos Siding sample, an average of the results is to be reported unless any of the results can be rejected for cause. 8. References 8.1. Dreesen, W.C., et al, U.S. Public Health Service: A Study of Asbestosis in the Asbestos Textile Industry, (Public Health Bulletin No. 241), US Treasury Dept., Washington, DC, 1938. 8.2. 

Asbestos Research Council: The Measurement of Airborne Asbestos Dust by the Membrane Filter How To Remove Asbestos Siding Method (Technical Note). Asbestos Research Council, Rockdale, Lancashire, Great Britain, 1969. 8.3. Bayer, S.G., Zumwalde, R.D., Brown, T.A., 

Equipment and Procedure for Mounting Millipore Filters and Counting Asbestos Fibers by Phase Contrast Microscopy, Bureau of Occupational Health, U.S. Dept. of Health, How To Remove Asbestos Siding Education and Welfare, Cincinnati, OH, 1969. 8.4. NIOSH Manual of Analytical Methods, 2nd ed., Vol. 1 (DHEW/ NIOSH Pub. No. 77-157-A). 

National Institute for Occupational Safety and Health, Cincinnati, OH, 1977. pp. 239-1-239-21. 8.5. Asbestos, Code of Federal Regulations 29 CFR 1910.1001. 1971. 8.6. Occupational Exposure to Asbestos, Tremolite, Anthophyllite, and Actinolite. Final How To Remove Asbestos Siding Rule, Federal Register 51:119 (20 June 1986). pp. 22612-22790. 8.7. 

Asbestos, Tremolite, Anthophyllite, and Actinolite, Code  of Federal Regulations 1910.1001. 1988. pp 711-752. 8.8. How To Remove Asbestos Siding Criteria for a Recommended Standard -- Occupational Exposure to Asbestos (DHEW/NIOSH Pub. No. HSM 72-10267), National Institute for Occupational Safety and Health NIOSH, Cincinnati,OH. 

Leidel, N.A., Bayer,S.G., Zumwalde, R.D.,Busch, K.A., USPHS/NIOSH Membrane Filter How To Remove Asbestos Siding Method for Evaluating Airborne Asbestos Fibers (DHEW/NIOSH Pub. No. 79-127). National Institute for Occupational Safety and Health, Cincinnati, OH.

Applications of Optical Microscopy in Analysis of Asbestos and Quartz, Analytical How To Remove Asbestos Siding Techniques in Occupational Health Chemistry, edited by D.D. Dollberg and A.W. Verstuyft. Wash. D.C.: American Chemical Society, (ACS Symposium Series 120) 1980. pp. 13-41. 

Quality Control The OSHA asbestos regulations require each laboratory to establish a quality control program. The following is presented as an example of how the OSHA-SLTC constructed its internal curve as part of meeting this requirement. Data is from How To Remove Asbestos Siding samples collected during OSHA compliance inspections and analyzed from October 1980 through April 1986. 

Each sample was counted by 2 to 5 different counters independently of one another. The standard deviation and the statistic was calculated for each sample. This How To Remove Asbestos Siding data was then plotted on a graph of vs. fibers/mm(2). A least squares regression was performed using the following equation: where: Application of least squares gave: 

Using these values, the equation becomes: Sampling Pump Flow Rate Corrections This How To Remove Asbestos Siding correction is used if a difference greater than 5% in ambient temperature and/or pressure is noted between calibration and sampling sites and the pump does not compensate for the differences. 

(For Equation D, ) Where: Q(act) = actual flow rate Q(cal) = calibrated flow rate (if a rotameter was used, the rotameter value) P(cal) = uncorrected air pressure at calibration P(act) = uncorrected air pressure at sampling site T(act) = temperature at How To Remove Asbestos Siding sampling site (K) T(cal) = temperature at calibration 

Graticule When ordering the Graticule for asbestos counting, specify the exact disc diameter needed to fit the ocular of the microscope and the diameter (mm) of the circular counting area. Instructions for measuring the How To Remove Asbestos Siding dimensions necessary are listed: (1) 

Insert any available graticule into the focusing eyepiece and focus so that the graticule lines are sharp and clear. (2) Align the microscope. (3) Place a stage micrometer on the microscope How To Remove Asbestos Siding object stage and focus the microscope on the graduated lines. (4) Measure the magnified grid length, PL (um), using the stage micrometer. 

Remove the graticule from the microscope and measure its actual grid length, AL (mm).  This can be accomplished by using a mechanical stage fitted with verniers, or a jeweler's loupe with a direct reading scale. (6) Let D = 100 um. Calculate the  How To Remove Asbestos Sidingcircle diameter, d(c)(mm), for the Walton-Beckett graticule and specify the diameter when making a purchase.

Each eyepiece-objective-reticle combination on the microscope must be calibrated. Should any of the three be changed (by zoom adjustment, disassembly, replacement, etc.), the  How To Remove Asbestos Siding combination must be recalibrated. Calibration may change if interpupillary distance is changed. 

Measure the field diameter.acceptable range: 100 plus or minus 2 um) with a stage micrometer upon receipt of the graticule from the manufacturer. Determine the How To Remove Asbestos Siding field area. The Graticule is available from: Graticules Ltd., Morley Road, Tonbridge TN9 IRN, Kent, England (Telephone 011-44-732-359061). 

Also available from PTR Optics Ltd., 145 Newton Street, Waltham, MA 02154 [telephone (617) 891-6000] or McCrone Accessories and How To Remove Asbestos Siding Components, 2506 S. Michigan Ave., Chicago, IL 60616 [phone (312)-842-7100]. The graticule is custom made for each microscope. Counts for the Fibers in the Figure.

What Is A Normal Dehumidifier Setting In Degrees

Recuperative heat exchange is a universal technology applicable to vapor-compression, direct-expansion, and chilled-water air-handling-unit (AHU) coils; heat-powered desiccant dehumidification equipment; dehumidifiers; supermarket, ice-rink, and natatorium air-conditioning and dehumidification   read more..

Flood Damage

When a flood passes through an area the damage that they can leave could be tremendous, if Electronic Restoration Flood Damage have entered a building containing state-of-the-art electronic equipment. These pieces of equipment will need to be thoroughly dried, gone through having all of the circuit boards and other electri  read more..

Flooded Areas With Lead based Paint Tennessee

(ATLANTA – May 26, 2010) – Due to recent flooding in western and central Tennessee, the U.S. Environmental Protection Agency (EPA) in Region 4 wants to ensure that families are not at increased risk for lead poisoning, because of clean up and/or Flood Damage Flooded Areas With Lead based Paint Tennessee repair work. 

  read more..

How To Abate Remove Lead

The employer shall maintain the record of the objective data relied upon for at least 30 years. (5) Availability. The employer shall make available upon request all records required to be maintained by subsection (n) to affected employees,former employees, and their designated representatives, and t  read more..

Water Removal

Did you know the average residential house loses 14% of the water delivered to leaks? In an average home, 22 gallons of water are lost to leakage every day, and the usual suspects are leaking toilets or dripping faucets. This daily leakage amount is about eq  read more..

How To Know If You Are A Hoarder

In non-emergency situations, the Mental Health Clinician conducts preliminary outreach via home visit or telephone in hopes of establishing rapport at the outset of the process, i.e. the carrot. Thus far, hoarders have been more amenable to establishing initial communication with a clinical responde  read more..

Abatement Asbestos

The following asbestos control program rules, shall apply to all asbestos abatement activities occurring within the City of New York. (b) Every owner of a building where asbestos abatement activity occurs shall be responsible for the performance of the asbestos abatement activities by his/her agent,  read more..

The Effects Meth Labs Have On Wildlife And Vegetat

In addition to the General Cleanup Requirements in Section B, at aminimum a typical cleanup for a Tier 2 Response shall Meth Lab Cleanup The Effects Meth Labs Have On Wildlife And Vegetat include the following:1) Where applicable/appropriate, follow all cleaning procedures described in Tier 1.2) This Tier differs from Tier 1 Responses in that additional af  read more..

Mold Mitigation

If there has been a lot of water damage, and/or mold growth covers more than 10 square feet, consult EPA's Mold Remediation in Schools and Commercial Buildings. Although focused on schools and commercial buildings, this Water Damage Mold Mitigation document is applicable to other building types. If you choose to hire  read more..

The Best Way To Fix A Wet Basement

Like relocation, demolition is very disruptive for the occupants of the house. Unless you decide to buy an existing house elsewhere, you must find a place to live and to store your furniture and Basement Drying The Best Way To Fix A Wet Basement belongings while your new house is being built. 